New-energy Photovoltaic|PV Power-station Case

Home > Blog > New-energy Photovoltaic|PV Power-station Case

New-energy Photovoltaic|PV Power-station Case

微信分享

请复制下面链接,在微信内打开分享
https://www.lstransformer.com/new-energy-photovoltaic%ef%bd%9cpv-power-station-case/

PV systems are composed of PV modules, combiner boxes, inverters, box-type transformers and grid-connection switch-cabinets. PV panels produce DC power that undergoes DC-AC conversion via inverters and is stepped-up by step-up transformers before being fed into public power grids. The most-typical operating-condition characteristic of PV power-stations lies in unstable power outputs: cloud-cover-shielding, day-night-alternation and morning-evening-illumination-variations bring sharp short-term fluctuations of generated power. Inverters belong to non-linear power-conversion equipment. High-frequency IGBT switching continuously produces harmonics and high-frequency-noise. Power-flows are bidirectional: power flows from inverter sides to grids in daytime power-generation periods; grids supply power to auxiliary loads inside power-stations (monitoring, cooling etc.) at night without power-generation. Outdoor open-air deployment brings large-amplitude-temperature-swings. Some regions feature dust-salt-spray-rain-water erosion. Designed for unidirectional steady-state power-frequency loads, general-purpose transformers and reactors cannot adapt to PV-scenario characteristics of randomly-fluctuating power outputs, heavy-harmonic-contents and bidirectional-power-flows. Under long-term harmonic-environment-operation, additional losses surge and temperatures rise sharply. Current-inrushes induced by illumination-changes readily cause magnetic-saturation and disable harmonic-governance functions. Without outdoor-weather-resistance protection, outdoor-deployed general-purpose-products readily suffer insulation-aging and corrosion-induced tripping-shutdown faults and may even fail grid-connection-acceptance by power grids. Custom-built for operating-conditions of PV inverters and box-transformers, special-purpose transformers and reactors for PV applications deliver reliable power-conversion and power-quality-governance solutions for centralized ground-mounted power-stations and industrial-commercial rooftop distributed PV systems.

Application of Transformers and Reactors in PV-system Scenarios

1.1 PV-specific Step-up / Isolation Transformer: Voltage Conversion, Galvanic Isolation and Bidirectional-power-flow Adaptation

Low-voltage AC power output by PV inverters requires step-up transformers to raise voltages to 10 kV or 35 kV levels to satisfy long-distance-power-transmission and grid-connection requirements. PV transformers realize galvanic isolation between inverter sides and grid sides, block DC-components and common-mode-interference generated by inverters from propagating toward grid sides and prevent DC-component-induced DC-magnetic-bias and over-heating of upstream power-distribution transformers. PV systems feature bidirectional-power-flow characteristics: PV modules generate power in daytime and power flows from inverter sides toward grids; grids supply power to auxiliary equipment inside power-stations at night without power-generation. Special-purpose transformers sustain stable bidirectional-power-transmission. Upon sharp power-rise-drop induced by illumination-changes, output-voltages remain stable and mitigate grid-connection-point-voltage-fluctuation and flicker phenomena. In case of short-circuit faults of inverters or cables, transformers limit short-circuit-fault-currents and prevent large-scale fault-propagation-expansion and protect inverter power devices. Meanwhile, isolation transformers mitigate harmonic-propagation and lower harmonic-superposition-effects induced by parallel-operation of multiple inverters.

1.2 Inverter Grid-connection Series Reactor: Suppress Grid-connection Inrush-currents and Damp Grid-resonance

Upon inverter grid-connection, large switch-on inrush-currents are generated that impact internal power devices of inverters and may break down IGBT modules directly in severe cases. Connected on inverter output sides, grid-connection reactors rely on inductive characteristics to slow current-rise-rates, suppress grid-connection switch-on inrush-currents and protect inverter-power units. When multiple inverters are connected in parallel to the same distribution-grid, output capacitances of inverters plus line-distributed capacitances readily resonate with grid-inductances, causing harmonic-amplification and voltage-oscillation and triggering batch-tripping of inverters. Grid-connection-reactors increase loop-damping coefficients, break resonance-conditions and suppress system-resonance risks. Meanwhile, reactors filter high-order harmonics generated by inverters effectively, lower total-current-harmonic-distortion-rate THD values at grid-connection-points, satisfy power-quality-index requirements of power grids for new-energy-station grid-connection and guarantee smooth grid-connection of power-stations. Upon grid-side voltage-drop faults, reactors cooperate with inverters to realize low-voltage-ride-through functions and improve fault-tolerance-capability of power-stations against grid-side faults.

1.3 Filter / Reactive-power-compensation Reactor: Harmonic-governance and Grid-connection-point-voltage-stabilization

Large-scale centralized PV power-stations are usually equipped with reactive-power-compensation cabinets. Compensation reactors are connected in series inside capacitor loops to suppress capacitor-switch-on inrush-surges, filter specific-order harmonics and prevent parallel-resonance between capacitors and power grids. PV-power-outputs keep changing along with illumination variations, resulting in continuous-fluctuation of system-reactive-power and readily inducing grid-connection-point-voltage-offset. Cooperating with reactive-power-compensation devices, compensation-reactors dynamically regulate system-reactive-power, stabilize grid-connection-point-voltages and maintain power-factors within grid-specified ranges to avoid electricity-penalties or grid-imposed power-generation-limitations induced by non-compliant power-factors. In weak-grid-regions, this device also improves grid-accommodation-capability for PV power-stations and reduces power-reduction and off-grid accidents of power-stations induced by over-limit voltages.

Core Advantages of PV-specific Products versus General-purpose Industrial Products

2.1 Bidirectional-power-transmission-supporting Design with Strong DC-magnetic-bias-resistance Performance

General-purpose industrial transformers are designed only for unidirectional-power-transmission and cannot cope with bidirectional-power-flow of PV-systems. Subject to DC-components leaking from inverters, they readily suffer DC-magnetic-bias with severe core-over-heating and sharp-noise-increase consequences. Optimized in magnetic-circuit design, PV-specific transformers suppress DC-magnetic-bias and sustain stable bidirectional-energy-flow, adapting to daytime-power-generation and night-time-grid-power-receiving operating-modes of PV-systems.

2.2 Optimized Harmonic-tolerance-performance with Anti-magnetic-saturation-capability under Large-current-inrushes

Harmonic-spectral-components of PV-systems are complex and illumination-variations bring transient-current-fluctuations. Optimized in core-air-gap-structure, special-purpose reactors resist magnetic-saturation under conditions of harmonic-superposition and short-term heavy-current-inrushes. Inductance-parameters remain stable and persistently deliver filtering and resonance-damping effects. General-purpose reactors readily saturate under harmonic-superposition-conditions and lose governance-functions.

2.3 Outdoor-weather-resistance-protection-process Adapts to Complex Open-air-environments

Equipment of ground-mounted PV power-stations is deployed in open-air conditions, subject to large-amplitude-temperature-cycling, dust-laden and rain-water-erosion. Coastal projects additionally suffer salt-spray-corrosion. Coils of products adopt VPI vacuum-pressure-impregnation with weather-resistant insulating-materials. Outer-housings can be coated with anti-corrosion layers to achieve moisture-proof, dust-proof and salt-spray-proof properties. Lacking outdoor-anti-corrosion-design, general-purpose indoor-industrial-products suffer rapid insulation-degradation and electric-leakage-corrosion-induced faults under open-air-conditions.

2.4 Low-loss Core-material-selection Reduces Self-power-consumption of Power-stations

PV power-stations pursue maximized power-generation-benefits. Self-losses of transformers directly affect power-generation yields of power-stations. Adopting high-grade low-loss silicon-steel sheets and optimized coil-winding-structure-design, products lower iron loss and copper loss, reduce self-heating and electric-energy-loss of equipment and improve overall power-generation-benefits of power-stations. General-purpose transformers feature relatively high losses and cause considerable power-generation-yield-losses under long-term-operation.

2.5 Modular-compact-structure Fits Integration-requirements of Inverter-cabins / Box-type-transformers

Internal installation-spaces of inverter-cabins and box-type-transformers are compact. We customize product outline-dimensions according to drawings from inverter-OEMs and box-transformer-OEMs, optimize weight-and-volume-parameters to facilitate complete-set-equipment integration and cut civil-engineering-and-cabinet-modification-costs for power-stations.

Industry-specific Problems Solved and Application Values

3.1 Resolve Difficult-grid-connection-acceptance Problems of PV Power-stations Induced by Non-compliant Grid-connection-point-power-quality

Harmonic-excess, voltage-flicker and weak-grid-resonance induced by parallel-operation of multiple inverters constitute core causes of failed grid-connection-acceptance for many PV projects. Combined solutions of transformers plus grid-connection-reactors govern harmonics, suppress resonances and stabilize grid-connection-point-voltages. National new-energy-station-grid-connection-power-quality-standards are satisfied to guarantee smooth grid-connection of power-stations and mitigate economic-losses induced by delayed power-generation of power-stations.

3.2 Mitigate Off-grid-and-power-reduction-risks Induced by Illumination-fluctuation-caused Grid-connection-inrushes

Cloud-cover-shielding and sharp-illumination-changes cause sharp-PV-power-output-variations, bringing inrush-currents and over-limit-voltages that trigger frequent protective-tripping of inverters and force power-reduction-operation of power-stations. Special-purpose reactors suppress grid-connection-inrushes and improve low-voltage-ride-through-capability, reduce off-grid and power-reduction events of power-stations, raise available-operating-hours of power-stations and increase power-generation-benefits.

3.3 Address High-operation-maintenance-and-spare-part-cost-problems Induced by Equipment-over-heating-and-early-aging under Outdoor-harsh-conditions

When general-purpose-industrial-components are deployed directly for PV-outdoor-scenarios, combined effects of harmonic-losses and environmental-temperature-variations cause severe equipment-over-heating, short insulation-service-life and high-replacement-costs for operation-maintenance-spare-parts. Optimized in magnetic-circuits, loss-performance and outdoor-protection-capabilities, PV-specific products greatly extend component-service-life, cut full-lifecycle-operation-maintenance-and-spare-part-costs for power-stations and guarantee long-term stable power-generation of PV power-stations.

Validated by temperature-rise-tests, harmonic-durability-tests and outdoor-environment-aging-tests, our series of special-purpose transformers and reactors for PV applications fit rooftop-distributed-PV, mountain-region-ground-mounted-PV and desert-large-scale-centralized-PV projects. They have been widely matched with mainstream domestic inverter-OEMs and box-transformer-complete-set-OEMs and deliver reliable voltage-conversion and power-quality-governance overall-solutions for new-energy PV power-stations.