{"id":1143,"date":"2026-07-22T05:32:56","date_gmt":"2026-07-22T05:32:56","guid":{"rendered":"https:\/\/lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/"},"modified":"2026-09-29T10:59:52","modified_gmt":"2026-09-29T10:59:52","slug":"how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/de\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/","title":{"rendered":"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained"},"content":{"rendered":"<p>In global power grid infrastructure, the stable operation of transformers is fundamental to electrical safety. The Temperature Rise Test serves as a core evaluation method directly impacting transformer insulation system reliability and service life. This article details the principles of the test, key execution points, and how it reveals insights into insulation performance.<\/p>\n<p><a href=\"https:\/\/www.lstransformer.com\/de\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-6206\" src=\"https:\/\/lstransformer.com\/wp-content\/uploads\/2026\/07\/46.png\" alt=\"\" width=\"920\" height=\"498\" srcset=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/46.png 920w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/46-300x162.png 300w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/46-768x416.png 768w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/46-600x325.png 600w\" sizes=\"(max-width: 920px) 100vw, 920px\" \/><\/a><\/p>\n<h2 style=\"text-align: left;\"><b><span style=\"font-family: Arial;\">Inhalt<\/span><\/b><b><\/b><\/h2>\n<h3><img class=\"anchorclass\" \/><em>1. Core Principles and Purpose of the Temperature Rise Test<\/em><b><\/b><\/h3>\n<p style=\"padding-left: 40px;\">Thermal Degradation of Insulation Materials\u00a0is one of the primary causes of transformer failure. High temperatures accelerate the chemical decomposition process of insulating materials (such as insulating oil and cellulose solid insulation in oil-paper composite systems), leading to a sharp decline in their electrical and mechanical strength, ultimately causing insulation failure or even catastrophic faults.<\/p>\n<p style=\"padding-left: 40px;\">The Temperature Rise Test\u00a0simulates transformer operation under rated load or specified overload conditions, measuring the temperature increase (temperature rise) at critical points when they reach a stable thermal state. Its main objectives are to verify:<\/p>\n<h6 style=\"padding-left: 80px;\"><b>(1) <\/b><b>Whether measured temperature rises meet design expectations and international standard limits:<\/b><b><\/b><\/h6>\n<p style=\"padding-left: 80px;\">Ensuring that during long-term rated operation, the internal hottest-spot temperature does not exceed the withstand limit of the used insulation material class.<\/p>\n<h6 style=\"padding-left: 80px;\"><b>(2) <\/b><b>The effectiveness of the cooling system:<\/b><b><\/b><\/h6>\n<p style=\"padding-left: 80px;\">Verifying if the design and performance of cooling devices (like radiators, fans, oil pumps) meet heat dissipation requirements.<\/p>\n<h6 style=\"padding-left: 80px;\"><b>(3) <\/b><b>Detection of structural defects:<\/b><\/h6>\n<p style=\"padding-left: 80px;\">Revealing abnormal local hot spots, which often signal potential insulation threats such as winding deformation, poor contacts, excessive stray losses, or blocked cooling ducts.<\/p>\n<h3><img class=\"anchorclass\" \/><em>2. Key Steps and Measurement Methods for the Temperature Rise Test<\/em><b><\/b><\/h3>\n<p>Tests are typically conducted in manufacturing plants or independent laboratories, strictly following procedures and environmental conditions (e.g., ambient temperature stability) stipulated by international standards like\u00a0IEC 60076-2 \/ IEEE C57.12.90 \/ ANSI C57.12.90.<i><\/i><\/p>\n<h4 style=\"padding-left: 40px;\"><b>2.1 Initial State Recording:<\/b><\/h4>\n<p style=\"padding-left: 40px;\">Measure and record the temperatures of all test points<i>(windings, top oil, bottom oil, core, structural parts, etc.)<\/i>\u00a0and the ambient temperature before starting the test.<\/p>\n<h4 style=\"padding-left: 40px;\"><b>2.2 Load Application &amp; Temperature Monitoring:<\/b><\/h4>\n<p style=\"padding-left: 40px;\">Apply power loss equivalent to the rated current or specified load (primarily winding I\u00b2R copper loss and core loss) using the short-circuit method (more common) or load method (directmethod).<\/p>\n<h4 style=\"padding-left: 40px;\"><b>2.3 Continuously monitor and record temperature changes at all key points. Measurement methods are crucial:<\/b><\/h4>\n<h6 style=\"padding-left: 80px;\"><b><\/b><strong>(1) Winding Resistance Method (Most Accurate):\u00a0<\/strong><b><\/b><\/h6>\n<p style=\"text-align: left; padding-left: 80px;\">Calculate average temperature rise by measuring DC resistance of windings in cold (pre-test) and hot states (immediately after de-energization), utilizing the linear relationship between resistance and temperature. Formula:<br \/>\n<b><\/b><\/p>\n<p style=\"text-align: center;\"><b><span style=\"font-family: \u5b8b\u4f53;\">\u2206\u03b8<\/span><span style=\"font-family: Cambria Math;\">_w = (R_h &#8211; R_c) \/ R_c * (T + k)<\/span><\/b><\/p>\n<p style=\"text-align: left; padding-left: 80px;\"><b><\/b><b><\/b>Wo:<br \/>\n\u2206\u03b8_w = Winding temperature rise (\u00b0C or \u00b0F)<br \/>\nR_h = Hot-state winding resistance measured immediately after de-energization (\u03a9)<br \/>\nR_c = Cold-state winding resistance at test start (\u03a9)<br \/>\nT = Constant (234.5 for copper, 225 for aluminum, unit \u00b0C; adjust accordingly for \u00b0F)<br \/>\nk = Cooling medium temperature at test end (\u00b0C or \u00b0F)<i><\/i><\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2) Top-Oil Temperature Measurement:\u00a0<\/strong><b><\/b><\/h6>\n<p style=\"padding-left: 80px;\">Use sensors immersed in the top oil (e.g., Pt100 platinum resistors).<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3) Hot-Spot Temperature Estimation Temperature Estimation:<\/strong><b><i><\/i><\/b><\/h6>\n<p style=\"padding-left: 80px;\">Direct measurement is extremely difficult; standards (e.g., IEC 60076-7) estimate it by adding a calculated &#8220;hot-spot-to-top-oil gradient&#8221; based on load current and design parameters to the top-oil temperature.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(4) Infrared Thermography (Auxiliary):<\/strong><b><i><\/i><\/b><\/h6>\n<p style=\"padding-left: 80px;\">Used to scan external components like tanks, radiators, bushings to help identify local overheating anomalies.<\/p>\n<h4 style=\"padding-left: 40px;\"><b>2.4 Achieving Thermal Stability:<\/b><\/h4>\n<p style=\"padding-left: 40px;\">Maintain applied load until temperature changes at all measured points do not exceed a specified value (e.g., 1-2\u00b0C\/hour) over consecutive hours (typically 3-4 hours).<\/p>\n<h4 style=\"padding-left: 40px;\"><b>2.5 Final Measurements &amp; Calculations:<\/b><\/h4>\n<h6 style=\"padding-left: 80px;\"><b>(1) Record final stabilized temperatures at measurement<\/b><b>\u00a0\u00a0<\/b><b>points and final ambient temperature.<\/b><b><br \/>\n<\/b><b>(2) Calculate Temperature Rise:<\/b><\/h6>\n<p style=\"padding-left: 80px; text-align: center;\"><b><i><\/i><\/b><b><span style=\"font-family: \u5b8b\u4f53;\">\u2206\u03b8<\/span><span style=\"font-family: Cambria Math;\">=<\/span><span style=\"font-family: \u5b8b\u4f53;\">\u03b8<\/span><span style=\"font-family: Cambria Math;\">_final &#8211;<\/span><span style=\"font-family: \u5b8b\u4f53;\">\u03b8<\/span><span style=\"font-family: Cambria Math;\">_ambient_final<\/span><\/b><\/p>\n<p style=\"padding-left: 80px;\"><b><\/b><b><\/b>Wo:<\/p>\n<p style=\"padding-left: 80px;\">\u2206\u03b8 = Measured point temperature rise (\u00b0C or \u00b0F)<\/p>\n<p style=\"padding-left: 80px;\">\u03b8_final = Final stabilized temperature of the measured point (\u00b0C or \u00b0F)<\/p>\n<p style=\"padding-left: 80px;\">\u03b8_ambient_final = Final ambient temperature (\u00b0C or \u00b0F)<\/p>\n<p style=\"padding-left: 80px;\">For windings, average temperature rise is usually calculated via the resistance method.<i><\/i><\/p>\n<h3><img class=\"anchorclass\" \/><em>3. Data Analysis and Insulation Performance Qualification Judgment<\/em><b><\/b><\/h3>\n<p>The core criterion for judging insulation performance qualification is whether the measured temperature rises (especially average winding rise and estimated hot-spot rise) are below the maximum allowable limits specified for the insulation material&#8217;s thermal class. Standards like<i>IEC 60076-2<\/i>\u00a0provide clear regulations.<\/p>\n<table width=\"785\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\" width=\"130\"><b>Insulation System Thermal Class<\/b><b><\/b><\/td>\n<td valign=\"center\" width=\"147\"><b>Max Allowable Hot-Spot Temp (\u00b0C)<\/b><b><\/b><\/td>\n<td valign=\"center\" width=\"206\"><b>Typical Avg Winding Rise Limit (Resistance Method, \u00b0C)<\/b><b><\/b><\/td>\n<td valign=\"center\" width=\"116\"><b>Top-Oil Temp Rise Limit (\u00b0C)<\/b><b><\/b><\/td>\n<td valign=\"center\" width=\"186\"><b>Example Materials<\/b><b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"130\">A (105)<\/td>\n<td valign=\"center\" width=\"147\">105 (120 Short-time)<\/td>\n<td valign=\"center\" width=\"206\">60 (ONAN) \/ 65 (OFAF)<\/td>\n<td valign=\"center\" width=\"116\">55 (ONAN) \/ 60 (OFAF)<\/td>\n<td valign=\"center\" width=\"186\">Impregnated paper, cotton yarn<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"130\">E (120)<\/td>\n<td valign=\"center\" width=\"147\">120<\/td>\n<td valign=\"center\" width=\"206\">75<\/td>\n<td valign=\"center\" width=\"116\">65<\/td>\n<td valign=\"center\" width=\"186\">Synthetic resin impregnated materials<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"130\">B (130)<\/td>\n<td valign=\"center\" width=\"147\">130 (140 Short-time)<\/td>\n<td valign=\"center\" width=\"206\">80 (ONAN) \/ 85 (OFAF)<\/td>\n<td valign=\"center\" width=\"116\">65 (ONAN) \/ 70 (OFAF)<\/td>\n<td valign=\"center\" width=\"186\">Mica, glass fiber, resin<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"130\">F (155)<\/td>\n<td valign=\"center\" width=\"147\">155 (175 Short-time)<\/td>\n<td valign=\"center\" width=\"206\">100 (ONAN) \/ 115 (OFAF)<\/td>\n<td valign=\"center\" width=\"116\">70 (ONAN) \/ 80 (OFAF)<\/td>\n<td valign=\"center\" width=\"186\">High-performance resins, mica, glass fiber<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"130\">H (180)<\/td>\n<td valign=\"center\" width=\"147\">180 (220 Short-time)<\/td>\n<td valign=\"center\" width=\"206\">125 (ONAN) \/ 140 (OFAF)<\/td>\n<td valign=\"center\" width=\"116\">Not specified<\/td>\n<td valign=\"center\" width=\"186\">Silicone organic materials, mica<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"table-note\" style=\"text-align: center;\">Table 1: Common Insulation System Thermal Classes &amp; Their Temperature Limits(Based on IEC 60076-2\/IEEE C57.12.00 Summary)<i><\/i><\/div>\n<h4 style=\"padding-left: 40px;\"><b>3.1 Qualification Logic:<\/b><b><\/b><\/h4>\n<h6 style=\"padding-left: 80px;\"><b>(1) Insulation Class Compatibility:<\/b><b><\/b><\/h6>\n<p style=\"padding-left: 80px;\">Measured temperature rise must be lower than the limit corresponding to the declared insulation thermal class of the transformer. For example, an &#8216;F&#8217; class transformer should not exceed 100\u00b0C average winding rise (resistance method, ONAN cooling), with estimated hot-spot temperature not exceeding 155\u00b0C.<\/p>\n<h6 style=\"padding-left: 80px;\"><b>(2) <\/b><b>No Local Overheating:<\/b><\/h6>\n<p style=\"padding-left: 80px;\">All component (core, structural parts, tank surface) temperature rises should be within reasonable ranges without significant localized hot spots markedly higher than similar parts. Abnormal local heating often signals early warnings of impending insulation failure, causing accelerated local thermal degradation.<\/p>\n<h6 style=\"padding-left: 80px;\"><b>(3) <\/b><b>Compliance with Specific Standards:<\/b><\/h6>\n<p style=\"padding-left: 80px;\">Results must holistically satisfy all relevant temperature rise clauses in the contractually agreed International\/National Standards (IEC, IEEE, ANSI, etc.).<\/p>\n<h4 style=\"padding-left: 40px;\"><b>3.2 Why Do Temperature Rise Limits Judge Insulation Performance?<\/b><b><\/b><\/h4>\n<h6 style=\"padding-left: 80px;\"><b>(1) <\/b><b>Material Life Model (Arrhenius Equation):<\/b><b><\/b><\/h6>\n<p style=\"padding-left: 80px;\">Insulation material aging rate approximately follows the Arrhenius law \u2013 roughly doubling for every 6-10\u00b0C increase (depending on material), halving its lifespan accordingly. The test verifies if the internal hottest-spot temperature remains within the safe range for long-term operation under continuous full load, preventing premature failure due to accelerated aging from thermal stress.<\/p>\n<h6 style=\"padding-left: 80px;\"><b>(2) <\/b><b>Insulating Oil Deterioration:<\/b><b><\/b><\/h6>\n<p style=\"padding-left: 80px;\">Excessive oil temperature accelerates oxidation, producing acids and sludge. Acids corrode solid insulation and metals, reducing performance; sludge blocks cooling ducts, worsens temperature rise, lowers breakdown voltage.<\/p>\n<h3><img class=\"anchorclass\" \/><em>4. Potential Insulation Issues Indicated by Abnormal Temperature Rise<\/em><b><\/b><\/h3>\n<p>Non-compliant or abnormal results strongly indicate underlying insulation issues:<\/p>\n<table width=\"793\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"141\"><b>Abnormal Phenomenon<\/b><b><\/b><\/td>\n<td valign=\"top\" width=\"333\"><b>Possible Causes<\/b><b><\/b><\/td>\n<td valign=\"top\" width=\"319\"><b>Impact on Insulation Performance<\/b><b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"141\">Overall Temperature Rise Exceeds Limit<\/td>\n<td valign=\"top\" width=\"333\">Design flaws (excessive losses, insufficient cooling surface); Cooling system failure (fan\/pump stoppage, blockage); Overload<\/td>\n<td valign=\"top\" width=\"319\">Accelerates overall thermal aging, shortening lifespan, increasing risk of sudden breakdown<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"141\">High\/Localized Winding Temp Rise<\/td>\n<td valign=\"top\" width=\"333\">Winding turn-to-turn shorts; Poor conductor contact; Excessive eddy currents from stray flux; Blocked cooling ducts<\/td>\n<td valign=\"top\" width=\"319\">Local overheating carbonizes paper insulation, cracks oil, drastically reduces dielectric strength, prone to short circuits<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"141\">High Top-Oil Temperature Rise<\/td>\n<td valign=\"top\" width=\"333\">Restricted oil flow (pump fault, pipe blockage); Low radiator efficiency (dirt, fan fault); Low oil level<\/td>\n<td valign=\"top\" width=\"319\">Accelerates oil oxidation, increases acidity, degrades oil insulation properties and cooling ability, corrodes solid insulation<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"141\">High\/Localized Core\/Structural Part Temp Rise<\/td>\n<td valign=\"top\" width=\"333\">Core ground faults; Excessive eddy currents in clamps\/bolts; Severe stray flux<\/td>\n<td valign=\"top\" width=\"319\">Risk of igniting insulation\/oil; Gases from overheating may affect DGA analysis interpretation<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"141\">Localized Tank Surface Overheat<\/td>\n<td valign=\"top\" width=\"333\">Internal areas of high eddy current loss; External magnetic shielding issues<\/td>\n<td valign=\"top\" width=\"319\">May reflect internal insulation design\/manufacturing defects, posing significant long-term risks<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"table-note\" style=\"text-align: center;\">Table 2: Abnormal Temperature Rise Phenomena vs. Potential Insulation Defects<\/div>\n<div><\/div>\n<p><a href=\"https:\/\/www.lstransformer.com\/de\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-3427\" src=\"https:\/\/lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133103060641.png\" alt=\"\" width=\"920\" height=\"498\" srcset=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133103060641.png 920w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133103060641-600x325.png 600w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133103060641-300x162.png 300w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133103060641-768x416.png 768w\" sizes=\"(max-width: 920px) 100vw, 920px\" \/><\/a><\/p>\n<h2 style=\"text-align: left;\"><b>Fazit<\/b><b><\/b><\/h2>\n<p>Far more than just a routine check, the Temperature Rise Test acts as a crucial &#8220;thermometer&#8221; diagnosing the long-term operational reliability of a transformer&#8217;s insulation system. By precisely measuring and scientifically analyzing if temperature distributions and rises comply with international standards and design insulation classes under simulated full-load conditions, we can effectively predict its insulation health status.<\/p>\n<p>A successful test signifies that even under demanding continuous loads, the transformer&#8217;s &#8220;heart&#8221; (insulation system) operates within safe temperature bounds, avoiding damage from thermal degradation. This ensures decades of reliable service, forming a robust foundation for grid stability, reduced outages, and lower maintenance costs.<\/p>\n<p>For power users, grid operators, and manufacturers alike, rigorously conducting standardized Temperature Rise Tests is indispensable for selecting, accepting, and ensuring high-quality transformer insulation performance \u2013 a globally recognized best practice.<\/p>\n<h2>Kontakt<\/h2>\n<p>\u96fb\u529b\u306e\u7b97\u51fa: <a href=\"https:\/\/www.lstransformer.com\/de\/\">single-phase transformer, three-phase-isolation in Transformatoren, elektrischen Transformator, Verteilung Transformator, step-down und step-up-Transformator, low-Spannung Transformator, hohe Spannung Transformator, Steuerung, Transformator, Ringkern Transformator, R-core-Transformator; DC-Spulen, AC Reaktoren, Filter-Reaktor -, line-und load reactor, drosseln, Filter-Reaktor, und die Mittel, hoch-Frequenz-Produkte<\/a>.<\/p>\n<p>\u304cV_peak\u7a4d\u306e\u904e\u96fb\u5727\u306e\u30d4\u30fc\u30af\u3068t_res\u306b\u5171\u9cf4\u3002 30%\u30de\u30fc\u30b8\u30f3\u63a8\u5968\u3092\u5360\u3081\u308b\u30b7\u30b9\u30c6\u30e0\u30d1\u30e9\u30e1\u30fc\u30bf\u5316\u3057\u307e\u3059\u3002<\/p>\n<p>2.2.3\u306e\u52d5\u7684\u5fdc\u7b54\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3 <a href=\"https:\/\/www.lstransformer.com\/de\/\">\u73fe\u4ee3\u306e\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u30b5\u30a4\u30ea\u30b9\u30bf\u5236\u5fa1\u306b\u3088\u308b\u62b5\u6297\u6e1b\u8870(TCRD)\u3092\u691c\u77e5\u3059\u308b\u5171\u9cf4\u518510ms\u3001\u914d\u306e\u6b63\u78ba\u6027\u3001\u5207\u65ad\u4e2d\u306e\u901a\u5e38\u306e\u64cd\u4f5c\u306f\u907f\u3051\u307e\u3059\u3002<\/a>.<\/p>\n<p>3. \u9023\u643a\u6a5f\u69cb\u306e\u30a2\u30af\u30c6\u30a3\u30d6\u30d5\u30a3\u30eb\u30bf<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\nE-Mail: marketing@hnlsdz.com<\/p>","protected":false},"excerpt":{"rendered":"<p>In global power grid infrastructure, the stable operation of transformers is fundamental to electrical safety. The Temperature Rise Test serves as a core evaluation method directly impacting transformer insulation system reliability and service life. This article details the principles of the test, key execution points, and how it reveals insights into insulation performance. Content 1. [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":3428,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1143","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD<\/title>\n<meta name=\"description\" content=\"In global power grid infrastructure, the stable operation of transformers is fundamental to electrical safety. The Temperature Rise Test serves as a core evaluation method directly impacting transformer insulation system reliability and service life. This article details the principles of the test, key execution points, and how it reveals insights into insulation performance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/de\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"og:description\" content=\"In global power grid infrastructure, the stable operation of transformers is fundamental to electrical safety. The Temperature Rise Test serves as a core evaluation method directly impacting transformer insulation system reliability and service life. This article details the principles of the test, key execution points, and how it reveals insights into insulation performance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/de\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:32:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-29T10:59:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133709204611.png\" \/>\n\t<meta property=\"og:image:width\" content=\"920\" \/>\n\t<meta property=\"og:image:height\" content=\"498\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained\",\"datePublished\":\"2026-07-22T05:32:56+00:00\",\"dateModified\":\"2026-09-29T10:59:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/\"},\"wordCount\":1420,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/17781133709204611.png\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/\",\"name\":\"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/17781133709204611.png\",\"datePublished\":\"2026-07-22T05:32:56+00:00\",\"dateModified\":\"2026-09-29T10:59:52+00:00\",\"description\":\"In global power grid infrastructure, the stable operation of transformers is fundamental to electrical safety. The Temperature Rise Test serves as a core evaluation method directly impacting transformer insulation system reliability and service life. This article details the principles of the test, key execution points, and how it reveals insights into insulation performance.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/17781133709204611.png\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/17781133709204611.png\",\"width\":920,\"height\":498},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/de\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"In global power grid infrastructure, the stable operation of transformers is fundamental to electrical safety. The Temperature Rise Test serves as a core evaluation method directly impacting transformer insulation system reliability and service life. This article details the principles of the test, key execution points, and how it reveals insights into insulation performance.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/de\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/","og_locale":"de_DE","og_type":"article","og_title":"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","og_description":"In global power grid infrastructure, the stable operation of transformers is fundamental to electrical safety. The Temperature Rise Test serves as a core evaluation method directly impacting transformer insulation system reliability and service life. This article details the principles of the test, key execution points, and how it reveals insights into insulation performance.","og_url":"https:\/\/www.lstransformer.com\/de\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:32:56+00:00","article_modified_time":"2026-09-29T10:59:52+00:00","og_image":[{"width":920,"height":498,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133709204611.png","type":"image\/png"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"369703005","Gesch\u00e4tzte Lesezeit":"10\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained","datePublished":"2026-07-22T05:32:56+00:00","dateModified":"2026-09-29T10:59:52+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/"},"wordCount":1420,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133709204611.png","articleSection":["FAQ"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/","url":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/","name":"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133709204611.png","datePublished":"2026-07-22T05:32:56+00:00","dateModified":"2026-09-29T10:59:52+00:00","description":"In global power grid infrastructure, the stable operation of transformers is fundamental to electrical safety. The Temperature Rise Test serves as a core evaluation method directly impacting transformer insulation system reliability and service life. This article details the principles of the test, key execution points, and how it reveals insights into insulation performance.","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133709204611.png","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17781133709204611.png","width":920,"height":498},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/how-to-determine-transformer-insulation-performance-through-temperature-rise-test-key-guidelines-explained\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"How to Determine Transformer Insulation Performance Through Temperature Rise Test? \u2013 Key Guidelines Explained"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS power Transformator, die Linie Reaktor, Hohe-Spannung Transformator, \u00d6l-eingetaucht Transformator-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS power Transformator, die Linie Reaktor, Hohe-Spannung Transformator, \u00d6l-eingetaucht Transformator-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/de\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/comments?post=1143"}],"version-history":[{"count":7,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1143\/revisions"}],"predecessor-version":[{"id":6207,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1143\/revisions\/6207"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/media\/3428"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/media?parent=1143"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/categories?post=1143"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/tags?post=1143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}