{"id":1189,"date":"2026-07-22T05:33:00","date_gmt":"2026-07-22T05:33:00","guid":{"rendered":"https:\/\/lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/"},"modified":"2026-10-29T06:55:27","modified_gmt":"2026-10-29T06:55:27","slug":"what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/de\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/","title":{"rendered":"Was Tun, Wenn die Blei Draht L\u00e4nge Ist Unzureichend W\u00e4hrend des vor-Ort-Transformator Installation?"},"content":{"rendered":"<h1>Was Tun, Wenn die Blei Draht L\u00e4nge Ist Unzureichend W\u00e4hrend des vor-Ort-Transformator Installation?<b><\/b><\/h1>\n<p>Vor-Ort-Transformator installation ist eine komplexe und akribische Aufgabe, und Unzureichende L\u00e4nge der Hochspannungs-Buchse Dr\u00e4hte ist eine gemeinsame Herausforderung Ingenieure Gesicht. Dieses Problem nicht nur Verz\u00f6gerungen von Zeitpl\u00e4nen f\u00fcr Projekte, sondern k\u00f6nnen auch dazu f\u00fchren, erh\u00f6hten \u00fcbergangswiderst\u00e4nde, lokalisierte \u00fcberhitzung und sogar Ausfall-oder Sicherheitsrisiken, die durch unsachgem\u00e4\u00dfe temporary fixes. Dieser Artikel bietet einen systematischen, wissenschaftlichen und International-konforme L\u00f6sung, um effektiv dieser Herausforderung zu begegnen.<\/p>\n<h2><b><span style=\"font-family: Arial;\">Inhalt<\/span><\/b><b><\/b><\/h2>\n<h3><em>1. Ursachen und M\u00f6gliche Risiken-Analyse<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><strong>1.1 Unzureichende Blei Draht L\u00e4nge kann scheinen, wie eine dreidimensionale Problem, aber es betrifft eigentlich mehrere Phasen, einschlie\u00dflich design, Herstellung, Transport und installation:<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Design\/Manufacturing Abweichung:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Unklar Zeichnungen oder Unzureichende Zulage f\u00fcr auf-Website Bedingungen w\u00e4hrend der Produktion.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Transportsch\u00e4den:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Geringf\u00fcgige Verschiebung der buchsen oder Tragegurte durch Vibrationen oder Auswirkungen w\u00e4hrend der gro\u00dfen Transformator Transport.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Installation Baseline Fehler:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Verlagerung der Stiftung embedments, bus, Rohre oder Kabeltrassen, was im kumulativen Abweichungen au\u00dferhalb der Toleranz.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(4)Umwelt-Faktoren:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Thermische expansion und Kontraktion der Metall-Komponenten, die aufgrund von extremen Temperaturschwankungen (vor allem in Regionen mit gro\u00dfen Tag-Nacht-Temperaturunterschiede).<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>1.2 dieses Thema Ignorieren kann zu schwerwiegenden Folgen f\u00fchren:<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)T\u00f6dliche \u00dcberhitzung:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">\u00dcber-angezogen, Dr\u00e4hte oder verformt Steckverbindungen reduzieren die effektive Kontaktieren Bereich, drastisch steigende Durchgangswiderstand (nach Joule ' s Gesetz,<img decoding=\"async\" id=\"loading_mj3miesm\" title=\"\u6b63\u5728\u4e0a\u4f20...\" src=\"http:\/\/manage.lstransformer.com\/plugins\/ueditor\/themes\/default\/images\/spacer.gif\" \/>Q=I2Rt), was zu burnout bei Verbindung Punkte oder sogar buchsen.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Isolationsdurchschlag:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Gezwungen ziehen kann Schaden Draht Isolierung oder Buchse Schwanz Isolierung; Unzureichende clearance in geschlossenen R\u00e4umen kann die Ursache f\u00fcr einen \u00fcberschlag.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Mechanische Besch\u00e4digung:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Dirigenten, buchsen oder unterst\u00fctzt ertragen zus\u00e4tzlichen stress, f\u00fchrt zu erm\u00fcdungsbr\u00fcchen oder \u00f6l-Leckagen durch Versagen der Dichtung im Laufe der Zeit.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(4)Hohe Kosten:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">\u00a0Ausfallzeiten, Demontage, Nacharbeiten, oder Ersatzteile zu erheblichen finanziellen Verlusten und Projektverz\u00f6gerungen.<\/p>\n<p><a href=\"https:\/\/www.lstransformer.com\/de\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-4050\" src=\"https:\/\/lstransformer.com\/wp-content\/uploads\/2026\/07\/17655895844295031.png\" alt=\"\" width=\"472\" height=\"453\" srcset=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17655895844295031.png 472w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17655895844295031-300x288.png 300w\" sizes=\"(max-width: 472px) 100vw, 472px\" \/><\/a><\/p>\n<h3><em>2. Wissenschaftliche L\u00f6sungen: Von Temporary Fixes zu Dauerhaften Aufl\u00f6sungen<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><strong>2.1 Professionelle Anschl\u00fcsse\/Erweiterung Fittings (Bevorzugte Methode)<\/strong><\/h4>\n<h5 style=\"padding-left: 80px;\"><strong>2.1.1 Grundgedanke:<\/strong><\/h5>\n<p style=\"padding-left: 80px;\">Verwenden hohe-Qualit\u00e4t Anschl\u00fcsse konform mit IEC 61238-1-oder IEEE-Std-386, wie Kupfer-Aluminium-\u00fcbergangs-terminals, Ger\u00e4te-Klemmen, oder die Erweiterung Rohre.<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.1.2 Mechanismus:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>(1) Nicht-Destruktive Verbindung:<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Kein schneiden von urspr\u00fcnglichen Dr\u00e4hte; Erweiterung Segmente sind fest verbunden via verschraubt oder hydraulische Crimpen, reibungslosen aktuellen \u00fcbergang.<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(2) Erf\u00fcllungsort Assurance:<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Hohe-Qualit\u00e4t Anschl\u00fcsse verwenden Sie spezielle Techniken (z.B., Reibung Schwei\u00dfen, L\u00f6ten) f\u00fcr molekulare Ebene kleben, die Minimierung der elektrochemischen Korrosion. Kontakt Widerstand ist weit unter IEC 61238-1 Anforderungen (typischerweise \u22641,1 x der Widerstand die gleiche L\u00e4nge Dirigent).<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(3) Flexibilit\u00e4t:<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Erh\u00e4ltlich in verschiedenen L\u00e4ngen und Winkeln zur Anpassung an Platzverh\u00e4ltnisse.<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.1.3 Wichtige Schritte:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>(1) Oberfl\u00e4che Prep:<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Reinigen Sie die Kontaktfl\u00e4chen gr\u00fcndlich und tragen Sie anti-Oxidationsmittel leitf\u00e4hige paste.<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(2) Torque Control:<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Verwenden Sie einen kalibrierten Drehmomentschl\u00fcssel, um die Schrauben zu Hersteller Spezifikationen, die f\u00fcr gleichm\u00e4\u00dfige Druckverteilung.<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(3) Testen:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Messen Kontaktieren Widerstand mit einem Mikro-ohmmeter post-installation um zu \u00fcberpr\u00fcfen die Qualit\u00e4t (IEC 60599 empfiehlt stabile Werte deutlich niedriger als die benachbarten Leiter-Widerstand).<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.1.4 Vorteile:<\/strong><\/h5>\n<p style=\"padding-left: 80px;\">H\u00f6chste Zuverl\u00e4ssigkeit, keine Sch\u00e4den an der Ausr\u00fcstung, und voller \u00fcbereinstimmung mit internationalen standards.<\/p>\n<p><a href=\"https:\/\/www.lstransformer.com\/de\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4051\" src=\"https:\/\/lstransformer.com\/wp-content\/uploads\/2026\/07\/17655895549312371.png\" alt=\"\" width=\"472\" height=\"453\" srcset=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17655895549312371.png 472w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17655895549312371-300x288.png 300w\" sizes=\"(max-width: 472px) 100vw, 472px\" \/><\/a><\/p>\n<h4 style=\"padding-left: 40px;\"><strong>2.2 Leiter Splei\u00dfen (mit Vorsicht Verwenden)<\/strong><\/h4>\n<h5 style=\"padding-left: 80px;\"><strong>2.2.1 Kernidee:<\/strong><\/h5>\n<p style=\"padding-left: 80px;\">F\u00fcr gro\u00dfe Verk\u00fcrzungen, schneiden original Draht und splice in Sie ein neues segment mit dem gleichen material und Querschnitt nach IEC 61238-1-konform oder straight butt connectors.<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.2.2 Risiken und die Schritte:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>(1) Pr\u00e4zision Schneiden:<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">\u00a0Sorgt f\u00fcr saubere und senkrechte Schnitte zu vermeiden fasertrennung.<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(2) Pressen\/Schwei\u00dfen:<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Cross-section-abgestimmt stirbt und Werkzeuge, nach GB\/T 14315 oder IEEE Std 1525. Post-crimp, Verhalten ziehen und Widerstand tests.<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(3) Isolierung Versorgung:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Verwenden Sie K\u00e4lte\/W\u00e4rme-schrumpfen Rohre, Isolier-Klebeband und einer wasserdichten Dichtstoffe, passenden die original-Isolierungs-Grad. Validierung standhalten Spannung tests.<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(4) Platzbedarf:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Splei\u00dfen erfordert zus\u00e4tzlichen Freiraum, die potenziell Auswirkungen auf Sicherheitsreserven.<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.2.3 Anwendbarkeit:<\/strong><\/h5>\n<p style=\"padding-left: 80px;\">Geeignet f\u00fcr gro\u00dfe R\u00e4ume mit professionellen Bedingungen.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>2.3 Anpassen Der Ger\u00e4te-Position (Sofern Stiftung Erm\u00f6glicht<\/strong>)<\/h4>\n<h5 style=\"padding-left: 80px;\"><strong>2.3.1 Grundgedanke:<\/strong><\/h5>\n<p style=\"padding-left: 80px;\">Leicht positionieren Sie den Transformator in einem sicheren Rahmen (z.B. mit einstellbare Stahl Unterlegscheiben) zu richten Dr\u00e4hte nat\u00fcrlich.<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.3.2 Wichtige Schritte:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>(1) Machbarkeitspr\u00fcfung:<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Best\u00e4tigen Sie mit Tragwerksplaner, dass die Anpassungen nicht beeintr\u00e4chtigen Stabilit\u00e4t.<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(2) Die Koordinierte Anpassungen:<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Sicherzustellen, Rohre, Kabelrinnen, - und bus-Kan\u00e4len Platz f\u00fcr die neue position.<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(3) Pr\u00e4zision Ausrichtung:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 120px;\">Verwenden Sie die laser-Ebenen zu erf\u00fcllen GB 50148 oder IEEE Std C57.12.00 standards f\u00fcr die Horizontalit\u00e4t und Ausrichtung.<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.3.3 Vorteile:<\/strong><\/h5>\n<p style=\"padding-left: 80px;\">Die meisten dauerhafte L\u00f6sung.<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.3.4 Einschr\u00e4nkungen:<\/strong><\/h5>\n<p style=\"padding-left: 80px;\">Beschr\u00e4nkt durch die Stiftung design und benachbarte Anlagen-layout (Anpassungen sind in der Regel nur ein paar Zentimeter).<\/p>\n<h3><em>3. Pr\u00e4vention als Heilen: wichtige Kontrollen W\u00e4hrend der Planung und Konstruktion<\/em><b><\/b><\/h3>\n<table width=\"651\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"139\"><b>Schl\u00fcssel Parameter<\/b><\/td>\n<td valign=\"top\" width=\"329\"><b>Design-Anforderungen<\/b><\/td>\n<td valign=\"top\" width=\"184\"><b>Standards Referenz<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\"><b>Design Marge<\/b><\/td>\n<td valign=\"top\" width=\"329\">Add 10%-15% L\u00e4nge f\u00fcr foundation Fehler, thermische expansion, und einbautoleranzen.<\/td>\n<td valign=\"top\" width=\"184\">IEEE Std C57.12.00, IEC 60076<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\"><b>3D-Simulation<\/b><\/td>\n<td valign=\"top\" width=\"329\">Verwenden ANSYS\/SolidWorks zu simulieren, Ausr\u00fcstung, Platzierung und die Sammelschienen-verbindungen.<\/td>\n<td valign=\"top\" width=\"184\">ANSYS, SolidWorks Simulation<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\"><b>Vor-Ort-Pr\u00fcfung<\/b><\/td>\n<td valign=\"top\" width=\"329\">Messen Buchse-zu-Anschluss-Abst\u00e4nde exakt post-installation f\u00fcr die Draht-Herstellung.<\/td>\n<td valign=\"top\" width=\"184\">GB 50150, IEEE Std C57.152<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\"><b>Material-Kompatibilit\u00e4t<\/b><\/td>\n<td valign=\"top\" width=\"329\">Geben Sie Leiter\/bushing Materialien (Cu\/Al) und ein Konto f\u00fcr die thermische Ausdehnung unterschieden.<\/td>\n<td valign=\"top\" width=\"184\">IEC 61238-1 (Cu-Al-Verbindungen)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\"><b>\u00d6kologische Ausgleich<\/b><\/td>\n<td valign=\"top\" width=\"329\">Berechnen expansion (\u0394L = \u03b1 \u00d7 L\u2080 \u00d7 \u0394T) f\u00fcr extreme Klimazonen; reserve Raum f\u00fcr expansion Gelenke.<\/td>\n<td valign=\"top\" width=\"184\">IEC 62271-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><em>4. Kern-Formel: Leiter Strombelastbarkeit und die Temperatur Ri<\/em><b>se<\/b><b><\/b><\/h3>\n<p>Unzureichende conductor sizing (auch mit ausreichender L\u00e4nge) ist eine h\u00e4ufige Gefahr. Key Formeln:<\/p>\n<h6 style=\"padding-left: 40px;\"><strong>(1) Die Strombelastbarkeit Der Berechnung:<\/strong><\/h6>\n<p style=\"text-align: center;\"><b>I=k\u00d7S\u03b8<\/b><\/p>\n<p style=\"padding-left: 40px;\">Wo:<\/p>\n<p style=\"padding-left: 40px;\">Ich: Zul\u00e4ssige Strom (A)<\/p>\n<p style=\"padding-left: 40px;\">S: Cross-sectional area (mm2)<\/p>\n<p style=\"padding-left: 40px;\">k, \u03b8: Material\/Isolierung\/Umwelt-abh\u00e4ngigen Koeffizienten.<\/p>\n<table cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"99\"><b>Dirigent<\/b><\/td>\n<td valign=\"top\" width=\"110\"><b>Isolierung<\/b><\/td>\n<td valign=\"top\" width=\"122\"><b>k (A\/mm2)<\/b><\/td>\n<td valign=\"top\"><b>Notes<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"99\">Kupfer<\/td>\n<td valign=\"top\" width=\"110\">XLPE<\/td>\n<td valign=\"top\" width=\"122\">11-15<\/td>\n<td valign=\"top\">Hohe Strombelastbarkeit, W\u00e4rme-best\u00e4ndig.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"99\">Kupfer<\/td>\n<td valign=\"top\" width=\"110\">PVC<\/td>\n<td valign=\"top\" width=\"122\">9-12<\/td>\n<td valign=\"top\">Niedrigere Kosten, moderate performance.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"99\">Aluminium<\/td>\n<td valign=\"top\" width=\"110\">XLPE<\/td>\n<td valign=\"top\" width=\"122\">7-9<\/td>\n<td valign=\"top\">Gr\u00f6\u00dferen Querschnitt ben\u00f6tigt vs. Cu.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"99\">Aluminium<\/td>\n<td valign=\"top\" width=\"110\">PVC<\/td>\n<td valign=\"top\" width=\"122\">6-8<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h6 style=\"padding-left: 40px;\"><strong>(2) Temperaturanstieg:<\/strong><\/h6>\n<p style=\"text-align: center;\"><strong>P = I2 \u00d7 R<\/strong><\/p>\n<p style=\"text-align: center;\"><strong>R = \u03c1 \u00d7 L \/ S<\/strong><b><\/b><\/p>\n<p style=\"padding-left: 40px;\">Sicherzustellen, das Gleichgewicht der Temperatur bleibt unten Isolierung<\/p>\n<p style=\"padding-left: 40px;\">Grenzen (z.B. 90\u00b0C XLPE).<\/p>\n<h2><b><span style=\"font-family: Arial;\">(2)\u5de5\u5b66\u7684\u306a\u7bc4\u56f2:(0.3~0.5)X_L@f\u1d63<\/span><\/b><b><\/b><\/h2>\n<p>Unzureichende Transformator Blei Draht L\u00e4nge ist ein Kritischer Zuverl\u00e4ssigkeit bedrohlich. Priorisieren standardisierte Erweiterung Beschl\u00e4ge f\u00fcr Sicherheit und Effizienz. Splei\u00dfen erfordert die strikte Einhaltung der IEC\/IEEE-standards, w\u00e4hrend die Ausr\u00fcstung der Neupositionierung ist ideal, aber Kontext-abh\u00e4ngig. Ultimate Pr\u00e4vention liegt in der design-Margen, 3D-Simulationen und genaue post-installation-Messungen.<\/p>\n<h2 style=\"font-weight: bold;\"><strong>Kontakt<\/strong><\/h2>\n<p>\u96fb\u529b\u306e\u7b97\u51fa: <a href=\"https:\/\/www.lstransformer.com\/de\/\">single-phase transformer, three-phase-isolation in Transformatoren, elektrischen Transformator, Verteilung Transformator, step-down und step-up-Transformator, low-Spannung Transformator, hohe Spannung Transformator, Steuerung, Transformator, Ringkern Transformator, R-core-Transformator; DC-Spulen, AC Reaktoren, Filter-Reaktor -, line-und load reactor, drosseln, Filter-Reaktor, und die Mittel, hoch-Frequenz-Produkte<\/a>.<\/p>\n<p>\u304cV_peak\u7a4d\u306e\u904e\u96fb\u5727\u306e\u30d4\u30fc\u30af\u3068t_res\u306b\u5171\u9cf4\u3002 30%\u30de\u30fc\u30b8\u30f3\u63a8\u5968\u3092\u5360\u3081\u308b\u30b7\u30b9\u30c6\u30e0\u30d1\u30e9\u30e1\u30fc\u30bf\u5316\u3057\u307e\u3059\u3002<\/p>\n<p>2.2.3\u306e\u52d5\u7684\u5fdc\u7b54\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3 <a href=\"https:\/\/www.lstransformer.com\/de\/\">\u73fe\u4ee3\u306e\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u30b5\u30a4\u30ea\u30b9\u30bf\u5236\u5fa1\u306b\u3088\u308b\u62b5\u6297\u6e1b\u8870(TCRD)\u3092\u691c\u77e5\u3059\u308b\u5171\u9cf4\u518510ms\u3001\u914d\u306e\u6b63\u78ba\u6027\u3001\u5207\u65ad\u4e2d\u306e\u901a\u5e38\u306e\u64cd\u4f5c\u306f\u907f\u3051\u307e\u3059\u3002<\/a>.<\/p>\n<p>3. \u9023\u643a\u6a5f\u69cb\u306e\u30a2\u30af\u30c6\u30a3\u30d6\u30d5\u30a3\u30eb\u30bf<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\nE-Mail: marketing@hnlsdz.com<\/p>","protected":false},"excerpt":{"rendered":"<p>What to Do When the Lead Wire Length Is Insufficient During On-Site Transformer Installation? On-site transformer installation is a complex and meticulous task, and insufficient length of high-voltage bushing lead wires is a common challenge engineers face. This issue not only delays project timelines but may also lead to increased contact resistance, localized overheating, and [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":4052,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1189","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Transformer Lead Wire Length for Installation | LuShan<\/title>\n<meta name=\"description\" content=\"Review options when transformer lead wires are too short during installation. Check connection layout, mechanical stress, insulation clearance and approved repair practices.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/de\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Transformer Lead Wire Length for Installation | LuShan\" \/>\n<meta property=\"og:description\" content=\"Review options when transformer lead wires are too short during installation. Check connection layout, mechanical stress, insulation clearance and approved repair practices.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/de\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:33:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-29T06:55:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765589916126281.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"370\" \/>\n\t<meta property=\"og:image:height\" content=\"276\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"What to Do When the Lead Wire Length Is Insufficient During On-Site Transformer Installation?\",\"datePublished\":\"2026-07-22T05:33:00+00:00\",\"dateModified\":\"2026-10-29T06:55:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/\"},\"wordCount\":1012,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1765589916126281.jpg\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/\",\"name\":\"Transformer Lead Wire Length for Installation | LuShan\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1765589916126281.jpg\",\"datePublished\":\"2026-07-22T05:33:00+00:00\",\"dateModified\":\"2026-10-29T06:55:27+00:00\",\"description\":\"Review options when transformer lead wires are too short during installation. Check connection layout, mechanical stress, insulation clearance and approved repair practices.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1765589916126281.jpg\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1765589916126281.jpg\",\"width\":370,\"height\":276},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What to Do When the Lead Wire Length Is Insufficient During On-Site Transformer Installation?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/de\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Transformer Lead Wire Length for Installation | LuShan","description":"Review options when transformer lead wires are too short during installation. Check connection layout, mechanical stress, insulation clearance and approved repair practices.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/de\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/","og_locale":"de_DE","og_type":"article","og_title":"Transformer Lead Wire Length for Installation | LuShan","og_description":"Review options when transformer lead wires are too short during installation. Check connection layout, mechanical stress, insulation clearance and approved repair practices.","og_url":"https:\/\/www.lstransformer.com\/de\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:33:00+00:00","article_modified_time":"2026-10-29T06:55:27+00:00","og_image":[{"width":370,"height":276,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765589916126281.jpg","type":"image\/jpeg"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"369703005","Gesch\u00e4tzte Lesezeit":"7\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"What to Do When the Lead Wire Length Is Insufficient During On-Site Transformer Installation?","datePublished":"2026-07-22T05:33:00+00:00","dateModified":"2026-10-29T06:55:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/"},"wordCount":1012,"commentCount":0,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765589916126281.jpg","articleSection":["FAQ"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/","url":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/","name":"Transformer Lead Wire Length for Installation | LuShan","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765589916126281.jpg","datePublished":"2026-07-22T05:33:00+00:00","dateModified":"2026-10-29T06:55:27+00:00","description":"Review options when transformer lead wires are too short during installation. Check connection layout, mechanical stress, insulation clearance and approved repair practices.","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765589916126281.jpg","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765589916126281.jpg","width":370,"height":276},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/what-to-do-when-the-lead-wire-length-is-insufficient-during-on-site-transformer-installation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"What to Do When the Lead Wire Length Is Insufficient During On-Site Transformer Installation?"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS power Transformator, die Linie Reaktor, Hohe-Spannung Transformator, \u00d6l-eingetaucht Transformator-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS power Transformator, die Linie Reaktor, Hohe-Spannung Transformator, \u00d6l-eingetaucht Transformator-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/de\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1189","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/comments?post=1189"}],"version-history":[{"count":5,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1189\/revisions"}],"predecessor-version":[{"id":7176,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1189\/revisions\/7176"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/media\/4052"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/media?parent=1189"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/categories?post=1189"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/tags?post=1189"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}