{"id":1191,"date":"2026-07-22T05:33:00","date_gmt":"2026-07-22T05:33:00","guid":{"rendered":"https:\/\/lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/"},"modified":"2026-10-29T06:55:27","modified_gmt":"2026-10-29T06:55:27","slug":"special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/de\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/","title":{"rendered":"Besondere Anforderungen f\u00fcr das aufziehen der Leiter in die Amorphe Legierung Transformatoren: die Technische Analyse und den Internationalen Standards Guide"},"content":{"rendered":"<h1 style=\"text-align: left;\">Besondere Anforderungen f\u00fcr das aufziehen der Leiter in die Amorphe Legierung Transformatoren: die Technische Analyse und den Internationalen Standards Guide<b><\/b><\/h1>\n<p>Als ein revolution\u00e4res material in der Transformator-Industrie, amorphen Legierung ist bekannt f\u00fcr seine extrem niedrigen core Verlust, Verringerung der Leerlauf-Energieverbrauch um 60%-80%. Jedoch, seine einzigartige Betriebseigenschaften stellen auch h\u00f6here Anforderungen an die Wicklung Dirigenten. Dieser Artikel befasst sich mit den speziellen Anforderungen f\u00fcr das aufziehen der Leiter in die amorphe Legierung Transformatoren, erl\u00e4utert die zugrunde liegenden technischen Prinzipien, und bietet L\u00f6sungen, die konform mit den internationalen standards (IEC, IEEE).<b>\u00a0<\/b><\/p>\n<h2><b><span style=\"font-family: Arial;\">Inhalt<\/span><\/b><b><\/b><\/h2>\n<h3><em>1. Umgang mit h\u00f6herfrequenten Oberschwingungen: Auswahl von Low-Verlust Leitf\u00e4hige Materialien<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><strong>1.1 Ursache:<\/strong><\/h4>\n<p style=\"padding-left: 40px;\">Die Magnetisierung-Kurve von amorphen Legierung ist &#8220;harder,&#8221; f\u00fchrt zu mehr Verzerrungen in der Erregung aktuelle Wellenform. Dies f\u00fchrt zu einer deutlich h\u00f6heren high-order harmonic content (vor allem 3., 5., und 7. harmonische) in die keine-Last Strom im Vergleich zu herk\u00f6mmlichen Silizium-Stahl Transformatoren. Wenn diese high-Frequenz Strom durch die Wicklung Leiter, Sie verursachen ausgepr\u00e4gte Haut-Effekte-und proximity-Effekte.<\/p>\n<p style=\"padding-left: 40px;\"><a title=\"Transformer, Wholesale Transformatoren Versorgt und Hersteller,Spezialisiert in Transformatoren f\u00fcr 50 Jahre\" href=\"https:\/\/www.lstransformer.com\/de\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter\" title=\"4\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1765268693908844.jpg\" alt=\"4\" width=\"400\" height=\"384\" border=\"0\" vspace=\"0\" \/><\/a><\/p>\n<h4 style=\"padding-left: 40px;\"><strong>1.2-Anforderung:Verwenden Sie Leiter mit hoher Leitf\u00e4higkeit und niedrigen Widerstand, vorzugsweise Sauerstoff-freies Kupfer (OFC).<\/strong><\/h4>\n<h4 style=\"padding-left: 40px;\"><strong>1.3 Prinzip und Wirkung:<\/strong><i><\/i><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1) die Leitf\u00e4higkeit und Verluste:<\/strong><\/h6>\n<p style=\"text-align: left; padding-left: 80px;\">Der Wechselstrom-Widerstand (Rac) der Dirigent unter der skin-Effekt ist deutlich h\u00f6her als der DC-Widerstand (Rdc). Die vereinfachte Formel f\u00fcr Rac:<\/p>\n<p style=\"text-align: center;\"><b>Rac \u2248 Rdc \u00d7 (1 + F)<\/b><b><\/b><\/p>\n<p style=\"padding-left: 80px;\">wo F ist ein Koeffizient bestimmt durch die H\u00e4ufigkeit, Dirigent Gr\u00f6\u00dfe und Form.<\/p>\n<p style=\"text-align: left; padding-left: 80px;\">Kupfer ist Durchgangswiderstand (<i>\u03c1 \u2248 1.68\u00d710\u207b\u2078 \u03a9\u00b7m @20\u00b0C<\/i>) ist viel niedriger als die von Aluminium (<i>\u03c1 \u2248 2.82\u00d710\u207b\u2078 \u03a9\u00b7m<\/i>). Unter den gleichen Bedingungen, Kupfer eine geringere Rac und nach Joule ' s Gesetz (P = I2R), dieser verringert die Belastung Verluste, die ist entscheidend f\u00fcr die Verbesserung der Effizienz der amorphe Legierung Transformatoren.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Haut-Tiefe:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Haut Tiefe (\u03b4) misst die effektive Eindringtiefe des Stromes in einem Leiter, wie folgt berechnet:<\/p>\n<p style=\"text-align: center;\"><b>\u03b4 = \u221a(\u03c1 \/ (\u03c0 \u00d7 f \u00d7 \u03bc))<\/b><b><\/b><\/p>\n<p style=\"text-align: left; padding-left: 80px;\">wo:<\/p>\n<p style=\"text-align: left; padding-left: 80px;\">\u03c1 = spezifischer Widerstand<\/p>\n<p style=\"text-align: left; padding-left: 80px;\">f = Frequenz<\/p>\n<p style=\"text-align: left; padding-left: 80px;\">\u00b5 = Permeabilit\u00e4t<i><\/i><\/p>\n<p style=\"padding-left: 80px;\">H\u00f6here Frequenzen (f) Ergebnis in kleineren Haut-Tiefe (\u03b4), so dass die aktuelle zu konzentrieren, in der N\u00e4he der Leiter Oberfl\u00e4che, Reduzierung der wirksamen Querschnittsfl\u00e4che und zunehmenden Widerstand. Kupfer ist hohe Leitf\u00e4higkeit sorgt f\u00fcr eine gr\u00f6\u00dfere Eindringtiefe bei der gleichen Frequenz, die Minimierung zus\u00e4tzliche Hochfrequenz-Verluste.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)die Vorteile der Sauerstoff-Freies Kupfer:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">OFC has extremely low oxygen content (&lt;5ppm) and fewer impurities, offering a more uniform crystal structure and conductivity close to the theoretical value of pure copper (100% IACS). This further reduces resistance and losses compared to standard electrolytic copper (ETP).<\/p>\n<p>&nbsp;<\/p>\n<p><a title=\"Transformer, Wholesale Transformatoren Versorgt und Hersteller,Spezialisiert in Transformatoren f\u00fcr 50 Jahre\" href=\"https:\/\/www.lstransformer.com\/de\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter\" title=\"3\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1765268729744737.jpg\" alt=\"3\" width=\"400\" height=\"384\" border=\"0\" vspace=\"0\" \/><\/a><\/p>\n<h3><em>2. EIGNUNG F\u00fcr Die H\u00f6here Thermische Belastung: Hochtemperatur-D\u00e4mmsystemen<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><strong>2.1 Ursache:<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Hotspot-Temperaturen:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Amorphen Legierung Kerne in der Regel bei h\u00f6heren magnetischen flussdichten. Obwohl Kern Verluste sind niedrig, die W\u00e4rme ist mehr konzentriert im Kern selbst. Die ultra-d\u00fcnnen amorphen Streifen (~25\u00b5m) haben kurze W\u00e4rmeleitung Pfade und schw\u00e4cher W\u00e4rmeableitung, m\u00f6glicherweise Erh\u00f6hung der Kerntemperatur und die \u00fcbertragung der W\u00e4rme zu benachbarten low-Spannung Wicklungen (vor allem die innere Schichten).<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)\u00dcberlastbarkeit:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Amorphen Legierung Streifen haben eine geringere Curie-Temperatur (~410\u00b0C) und sind anf\u00e4llig f\u00fcr Kristallisation und Verspr\u00f6dung bei hohen Temperaturen. Um sicherzustellen core Sicherheit, konservative Temperaturanstieg Grenzen (nach IEC 60076-oder IEEE C57.12.00\/01) angenommen werden, erfordern Isolierung Systeme arbeiten zuverl\u00e4ssig unter strenger thermische Einschr\u00e4nkungen.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>2.2 Anforderung:<\/strong><\/h4>\n<p style=\"padding-left: 40px;\">Verwenden Isolierung Materialien mit h\u00f6heren thermischen Klassen (z.B. H-Klasse oder h\u00f6her) und optimieren Isolierung design.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>2.3 Prinzip und Wirkung:<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)H\u00f6here Thermische Klasse:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Lieber H-Klasse (180\u00b0C) oder h\u00f6her Isolierung (z.B. Nomex\u00ae - Nennstrom bei 220\u00b0C) gegen\u00fcber der herk\u00f6mmlichen B-Klasse (130\u00b0C) oder F-Klasse (155\u00b0C) Materialien.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Material Eigenschaften:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Hohe-Temperatur Isolierung Materialien (z.B. Polyimid-Folien -, aramid-Papier, hohe-Temperatur-Harze) behalten ausgezeichnete elektrische St\u00e4rke, mechanische Integrit\u00e4t, und aging Widerstand bei erh\u00f6hten Temperaturen. Zum Beispiel Nomex\u00ae (DuPont aramid Papier) ertragen k\u00f6nnen Zehntausende Stunden bei 220\u00b0C, wobei B-Klasse Materialien zersetzen sich rasch.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Thermische Alterung Lebensdauer:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Isolierung Lebensdauer folgt dem Arrhenius-Gesetz: jede 10\u00b0C erh\u00f6hen, verdoppelt sich die-aging-rate. H\u00f6here thermische Klasse Materialien weisen langsamer Altern bei der gleichen Betriebstemperatur, erheblich verl\u00e4ngert Transformator Leben.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(4)Struktureller Entwurf:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Optimieren Wicklung layouts (z.B., hinzuf\u00fcgen K\u00fchlung Kan\u00e4le), und verwenden Sie thermisch leitf\u00e4hige Isolierung (z.B., Epoxidharz mit F\u00fcllstoffen) zur Abf\u00fchrung der W\u00e4rme schneller, Senkung der Betriebstemperaturen.<\/p>\n<p><a title=\"Transformer, Wholesale Transformatoren Versorgt und Hersteller,Spezialisiert in Transformatoren f\u00fcr 50 Jahre\" href=\"https:\/\/www.lstransformer.com\/de\/High-frequency-reactor\/24mh-106a\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter\" title=\"7\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1765268760792744.jpg\" alt=\"7\" width=\"400\" height=\"384\" border=\"0\" vspace=\"0\" \/><\/a><\/p>\n<h3><em>3. Die Anpassung an Einzigartige Mechanische Eigenschaften: Flexible Leitungen und sto\u00dffeste Strukturen<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><strong>3.1 Ursache:<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Hauptmerkmale:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Amorphen Legierung Streifen sind von Natur aus hart und spr\u00f6de. Elektromagnetische Kr\u00e4fte w\u00e4hrend des Betriebs verursachen Mikro-Vibrationen \u00fcbertragen Wicklungen \u00fcber-core-Klemmen und Abstandshalter.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Short-Circuit Forces:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Bei St\u00f6rungen, Wicklungen ertragen massive sofortige elektromagnetische Kr\u00e4fte (Lorentz-Kr\u00e4fte). Die mechanische D\u00e4mpfung des amorphen Kerne unterscheidet sich von Silizium-Stahl.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>3.2 Anforderung:<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Dirigent Flexibilit\u00e4t:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Verwenden Sie einen weichen, biegsamen Leitungen (z.B., gut angelassen weiche Kupfer) und small-gauge-Dr\u00e4hte (z.B., gestrandet oder umgesetzt Dirigenten).<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Strukturelle Verst\u00e4rkung:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Wicklungen brauchen stabile Unterst\u00fctzung und Spann -, um zu widerstehen Vibrationen und Kurzschluss-Kr\u00e4fte.<\/p>\n<p><a title=\"Transformer, Wholesale Transformatoren Versorgt und Hersteller,Spezialisiert in Transformatoren f\u00fcr 50 Jahre\" href=\"https:\/\/www.lstransformer.com\/de\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter\" title=\"9\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1765268825243447.jpg\" alt=\"9\" width=\"400\" height=\"384\" border=\"0\" vspace=\"0\" \/><\/a><\/p>\n<h4 style=\"padding-left: 40px;\"><strong>3.3 Prinzip und Wirkung:<\/strong><\/h4>\n<h5 style=\"padding-left: 80px;\"><strong>3.3.1 Flexible Leiter:<\/strong><\/h5>\n<p style=\"padding-left: 80px;\">Weiches Kupfer widersteht work-hardening-Frakturen unter wiederholter Belastung. Small-gauge-Dr\u00e4hte (z.B., Litz wire) eine bessere Anpassung an den core-induzierte Schwingungen, die Verringerung Isolierung tragen. Bei St\u00f6rungen, flexible Leiter absorbieren Auswirkungen Energie.<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>3.3.2 Short-Circuit Resistance:<\/strong><\/h5>\n<p style=\"padding-left: 80px;\">Short-circuit forces (F) proportional zum Strom im Quadrat (I2). Zu den wichtigsten Ma\u00dfnahmen geh\u00f6ren:<\/p>\n<h6 style=\"padding-left: 120px;\"><strong>(1) Hohe-Festigkeit Isolierung Zylinder (z.B., pre-compressed board oder CRGE) f\u00fcr die radiale Unterst\u00fctzung.<\/strong><br \/>\n<strong>(2) die Axialen Spannkr\u00e4fte (F_clamp &gt; K \u00d7 F_max_axial, wobei K &gt; 1.5).<\/strong><br \/>\n<strong>(3) Optimierte Abstandhalter und Bl\u00f6cke (z.B., high-density-laminate) Verteilung der Kr\u00e4fte.<\/strong><br \/>\n<strong>(4) Verst\u00e4rkte Wicklung endet (z.B., Formteile Winkel Ringe) zu verhindern Verformung.<\/strong><i><\/i><\/h6>\n<table width=\"746\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"118\"><b>Voraussetzung Kategorie<\/b><\/td>\n<td valign=\"top\" width=\"170\"><b>Core Challenge<\/b><\/td>\n<td valign=\"top\" width=\"211\"><b>Besondere Anforderungen f\u00fcr Leiter\/ - D\u00e4mmung<\/b><\/td>\n<td valign=\"top\" width=\"247\"><b>Key Solutions &amp; Technische Grundlagen<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"118\">Low-Loss-Leitf\u00e4higkeit<\/td>\n<td valign=\"top\" width=\"170\">Hohe Obert\u00f6ne \u2192 Haut-und proximity-Effekte<\/td>\n<td valign=\"top\" width=\"211\">Hohe Leitf\u00e4higkeit, niedrigen Widerstand<\/td>\n<td valign=\"top\" width=\"247\">Material: Sauerstoff-freies Kupfer (OFC). Leiter Typ: Litz\/umgesetzt Dr\u00e4hte.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"118\">Hohe-Temperatur Isolierung<\/td>\n<td valign=\"top\" width=\"170\">H\u00f6here core-temps\/strengere Grenzwerte<\/td>\n<td valign=\"top\" width=\"211\">H\u00f6here thermische Klasse (H-Klasse+)<\/td>\n<td valign=\"top\" width=\"247\">Material: Polyimid, Nomex\u00ae, hoch-temp-Harze. Design: Verbesserte K\u00fchlung Pfade.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"118\">Flexibilit\u00e4t Und Auswirkungen Widerstand<\/td>\n<td valign=\"top\" width=\"170\">Core Schwingungen\/short-circuit forces<\/td>\n<td valign=\"top\" width=\"211\">Flexible Leitungen; robuste Struktur<\/td>\n<td valign=\"top\" width=\"247\">Leiter: Weiche Kupfer-Litzen. Struktur: Verst\u00e4rkt unterst\u00fctzt\/spannen.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"table-note\" style=\"text-align: center;\"><i>Tabelle 1: die Wichtigsten Anforderungen und L\u00f6sungen f\u00fcr Amorphe Transformator-Leiter<\/i><\/div>\n<table width=\"670\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"111\"><b>Eigenschaft<\/b><\/td>\n<td valign=\"top\" width=\"72\"><b>Einheit<\/b><\/td>\n<td valign=\"top\" width=\"134\"><b>Kupfer (Cu)<\/b><\/td>\n<td valign=\"top\" width=\"140\"><b>Aluminium (Al)<\/b><\/td>\n<td valign=\"top\" width=\"213\"><b>Relevanz Amorphen Transformatoren<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"111\">Durchgangswiderstand (20\u00b0C)<\/td>\n<td valign=\"top\" width=\"72\">\u03a9\u00b7m<\/td>\n<td valign=\"top\" width=\"134\">\u2248 1.68\u00d710\u207b\u2078<\/td>\n<td valign=\"top\" width=\"140\">\u2248 2.82\u00d710\u207b\u2078<\/td>\n<td valign=\"top\" width=\"213\">Niedriger Cu-Widerstand verringert Verluste.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"111\">Leitf\u00e4higkeit (IACS %)<\/td>\n<td valign=\"top\" width=\"72\">%<\/td>\n<td valign=\"top\" width=\"134\">100%<\/td>\n<td valign=\"top\" width=\"140\">\u2248 61%<\/td>\n<td valign=\"top\" width=\"213\">H\u00f6here Cu Leitf\u00e4higkeit verbessert die Effizienz.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"111\">Dichte<\/td>\n<td valign=\"top\" width=\"72\">g\/cm3<\/td>\n<td valign=\"top\" width=\"134\">\u2248 8.96<\/td>\n<td valign=\"top\" width=\"140\">\u2248 2.70<\/td>\n<td valign=\"top\" width=\"213\">Al ist leichter, mechanisch schw\u00e4cher.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"111\">Zugfestigkeit<\/td>\n<td valign=\"top\" width=\"72\">MPa<\/td>\n<td valign=\"top\" width=\"134\">Soft: 200-250; Hart: 350-450<\/td>\n<td valign=\"top\" width=\"140\">Soft: 60-100; Hart: 150-200<\/td>\n<td valign=\"top\" width=\"213\">Cu bietet eine h\u00f6here Kurzschlussfestigkeit.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"111\">Dehnung (Weich)<\/td>\n<td valign=\"top\" width=\"72\">%<\/td>\n<td valign=\"top\" width=\"134\">&gt; 30%<\/td>\n<td valign=\"top\" width=\"140\">&gt; 20%<\/td>\n<td valign=\"top\" width=\"213\">Cu Flexibilit\u00e4t passt core Schwingungen.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"111\">W\u00e4rmeleitf\u00e4higkeit<\/td>\n<td valign=\"top\" width=\"72\">W\/(m\u00b7K)<\/td>\n<td valign=\"top\" width=\"134\">\u2248 400<\/td>\n<td valign=\"top\" width=\"140\">\u2248 235<\/td>\n<td valign=\"top\" width=\"213\">Cu leitet W\u00e4rme mehr effektiv.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"111\">Kosten<\/td>\n<td valign=\"top\" width=\"72\">(Variable)<\/td>\n<td valign=\"top\" width=\"134\">H\u00f6her<\/td>\n<td valign=\"top\" width=\"140\">Unteren<\/td>\n<td valign=\"top\" width=\"213\">Al ist billiger, aber weniger performant.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"table-note\" style=\"text-align: center;\"><i>Tabelle 2: Kupfer gegen Aluminium-Leiter-Eigenschaften (gem\u00e4\u00df IEC 60228)<\/i><b>\u00a0<\/b><\/div>\n<p><b>\u00a0<\/b><\/p>\n<h2><b><span style=\"font-family: Arial;\">(2)\u5de5\u5b66\u7684\u306a\u7bc4\u56f2:(0.3~0.5)X_L@f\u1d63<\/span><\/b><\/h2>\n<p>Amorphe Legierung Transformatoren sind entscheidend f\u00fcr die Energie-effiziente power Systeme. Ihre ultra-niedrig, keine-Last Verluste Nachfrage strenge Dirigent\/insulation standards: hohe Leitf\u00e4higkeit (vorzugsweise OFC), hohe thermische Klasse (H-Klasse+), und \u00fcberlegene mechanische Flexibilit\u00e4t. Das Verst\u00e4ndnis der zugrunde liegenden Prinzipien (skin-Effekt, thermische Alterung, Kurzschluss-Kr\u00e4fte) und die Einhaltung der IEC\/IEEE-standards (z.B. IEC 60076, IEEE C57) sorgt f\u00fcr globales Zuverl\u00e4ssigkeit.<\/p>\n<p>Optimiert Leiter und Isolierung Entscheidungen, gepaart mit einem robusten designs, maximieren Energie Einsparungen, verbessern Fehler Widerstand, und verl\u00e4ngern die Lebensdauer\u2014liefert unvergleichliche lifecycle-Wert f\u00fcr power-L\u00f6sungen weltweit.<\/p>\n<h2 style=\"font-weight: bold;\"><strong>Kontakt<\/strong><\/h2>\n<p>\u96fb\u529b\u306e\u7b97\u51fa: <a href=\"https:\/\/www.lstransformer.com\/de\/\">single-phase transformer, three-phase-isolation in Transformatoren, elektrischen Transformator, Verteilung Transformator, step-down und step-up-Transformator, low-Spannung Transformator, hohe Spannung Transformator, Steuerung, Transformator, Ringkern Transformator, R-core-Transformator; DC-Spulen, AC Reaktoren, Filter-Reaktor -, line-und load reactor, drosseln, Filter-Reaktor, und die Mittel, hoch-Frequenz-Produkte<\/a>.<\/p>\n<p>\u304cV_peak\u7a4d\u306e\u904e\u96fb\u5727\u306e\u30d4\u30fc\u30af\u3068t_res\u306b\u5171\u9cf4\u3002 30%\u30de\u30fc\u30b8\u30f3\u63a8\u5968\u3092\u5360\u3081\u308b\u30b7\u30b9\u30c6\u30e0\u30d1\u30e9\u30e1\u30fc\u30bf\u5316\u3057\u307e\u3059\u3002<\/p>\n<p>2.2.3\u306e\u52d5\u7684\u5fdc\u7b54\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3 <a href=\"https:\/\/www.lstransformer.com\/de\/\">\u73fe\u4ee3\u306e\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u30b5\u30a4\u30ea\u30b9\u30bf\u5236\u5fa1\u306b\u3088\u308b\u62b5\u6297\u6e1b\u8870(TCRD)\u3092\u691c\u77e5\u3059\u308b\u5171\u9cf4\u518510ms\u3001\u914d\u306e\u6b63\u78ba\u6027\u3001\u5207\u65ad\u4e2d\u306e\u901a\u5e38\u306e\u64cd\u4f5c\u306f\u907f\u3051\u307e\u3059\u3002<\/a>.<\/p>\n<p>3. \u9023\u643a\u6a5f\u69cb\u306e\u30a2\u30af\u30c6\u30a3\u30d6\u30d5\u30a3\u30eb\u30bf<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\nE-Mail: marketing@hnlsdz.com<\/p>","protected":false},"excerpt":{"rendered":"<p>Special Requirements for Winding Conductors in Amorphous Alloy Transformers: Technical Analysis and International Standards Guide As a revolutionary material in the transformer industry, amorphous alloy is renowned for its extremely low core loss, reducing no-load energy consumption by 60%-80%. However, its unique operational characteristics also impose higher demands on winding conductors. This article delves into [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":4060,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1191","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Winding Conductors for Amorphous Alloy Transformers | LuShan<\/title>\n<meta name=\"description\" content=\"Explore winding-conductor requirements for amorphous-alloy transformers. Consider current, temperature, mechanical stress and insulation compatibility at the connection.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/de\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Winding Conductors for Amorphous Alloy Transformers | LuShan\" \/>\n<meta property=\"og:description\" content=\"Explore winding-conductor requirements for amorphous-alloy transformers. Consider current, temperature, mechanical stress and insulation compatibility at the connection.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/de\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:33:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-29T06:55:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765268854342262.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"370\" \/>\n\t<meta property=\"og:image:height\" content=\"276\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"Special Requirements for Winding Conductors in Amorphous Alloy Transformers: Technical Analysis and International Standards Guide\",\"datePublished\":\"2026-07-22T05:33:00+00:00\",\"dateModified\":\"2026-10-29T06:55:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/\"},\"wordCount\":1198,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1765268854342262.jpg\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/\",\"name\":\"Winding Conductors for Amorphous Alloy Transformers | LuShan\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1765268854342262.jpg\",\"datePublished\":\"2026-07-22T05:33:00+00:00\",\"dateModified\":\"2026-10-29T06:55:27+00:00\",\"description\":\"Explore winding-conductor requirements for amorphous-alloy transformers. Consider current, temperature, mechanical stress and insulation compatibility at the connection.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1765268854342262.jpg\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1765268854342262.jpg\",\"width\":370,\"height\":276},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Special Requirements for Winding Conductors in Amorphous Alloy Transformers: Technical Analysis and International Standards Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/de\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Winding Conductors for Amorphous Alloy Transformers | LuShan","description":"Explore winding-conductor requirements for amorphous-alloy transformers. Consider current, temperature, mechanical stress and insulation compatibility at the connection.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/de\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/","og_locale":"de_DE","og_type":"article","og_title":"Winding Conductors for Amorphous Alloy Transformers | LuShan","og_description":"Explore winding-conductor requirements for amorphous-alloy transformers. Consider current, temperature, mechanical stress and insulation compatibility at the connection.","og_url":"https:\/\/www.lstransformer.com\/de\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:33:00+00:00","article_modified_time":"2026-10-29T06:55:27+00:00","og_image":[{"width":370,"height":276,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765268854342262.jpg","type":"image\/jpeg"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"369703005","Gesch\u00e4tzte Lesezeit":"8\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"Special Requirements for Winding Conductors in Amorphous Alloy Transformers: Technical Analysis and International Standards Guide","datePublished":"2026-07-22T05:33:00+00:00","dateModified":"2026-10-29T06:55:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/"},"wordCount":1198,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765268854342262.jpg","articleSection":["FAQ"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/","url":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/","name":"Winding Conductors for Amorphous Alloy Transformers | LuShan","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765268854342262.jpg","datePublished":"2026-07-22T05:33:00+00:00","dateModified":"2026-10-29T06:55:27+00:00","description":"Explore winding-conductor requirements for amorphous-alloy transformers. Consider current, temperature, mechanical stress and insulation compatibility at the connection.","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765268854342262.jpg","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1765268854342262.jpg","width":370,"height":276},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/special-requirements-for-winding-conductors-in-amorphous-alloy-transformers-technical-analysis-and-international-standards-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"Special Requirements for Winding Conductors in Amorphous Alloy Transformers: Technical Analysis and International Standards Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS power Transformator, die Linie Reaktor, Hohe-Spannung Transformator, \u00d6l-eingetaucht Transformator-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS power Transformator, die Linie Reaktor, Hohe-Spannung Transformator, \u00d6l-eingetaucht Transformator-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/de\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1191","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/comments?post=1191"}],"version-history":[{"count":5,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1191\/revisions"}],"predecessor-version":[{"id":6323,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1191\/revisions\/6323"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/media\/4060"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/media?parent=1191"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/categories?post=1191"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/tags?post=1191"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}