{"id":1401,"date":"2026-07-22T05:33:19","date_gmt":"2026-07-22T05:33:19","guid":{"rendered":"https:\/\/lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/"},"modified":"2026-10-29T06:55:50","modified_gmt":"2026-10-29T06:55:50","slug":"what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/de\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/","title":{"rendered":"Was ist die Beziehung zwischen Transformator Isolierung Ebene und Temperatur Aufstieg standard\uff1f"},"content":{"rendered":"<h1 style=\"text-align: left;\">Was ist die Beziehung zwischen Transformator Isolierung Ebene und Temperatur Aufstieg standard\uff1f<\/h1>\n<p><a href=\"https:\/\/www.lstransformer.com\/de\/Transformers\/\" target=\"_self\"><img decoding=\"async\" class=\"aligncenter\" title=\"150\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1742783662645128.jpg\" alt=\"undefined\" \/><\/a><\/p>\n<p>Isolierung Ebene und Temperatur Aufstieg:<\/p>\n<p style=\"padding-left: 40px;\">Der Isolationswert eines Transformators bezieht sich auf die maximal zul\u00e4ssige Temperatur steigen, was die W\u00e4rme Widerstand der Isolierung material verwendet in die Transformator. Die Temperatur steigt, auf der anderen Seite, bezieht sich auf die Temperaturdifferenz zwischen der Innenseite des Transformators und seiner Umgebung.<\/p>\n<p style=\"padding-left: 40px;\">Der Isolationswert von Transformatoren klassifiziert in verschiedene Ebenen, wie A, E, B, F und H. Jede Isolierung Ebene entspricht eine unterschiedliche maximal zul\u00e4ssige Temperaturanstieg zu begrenzen. F\u00fcr Beispiel, die A-level-Isolierung wicklungserw\u00e4rmung limit 60K, wird die E-Ebene Isolierung wicklungserw\u00e4rmung limit 75K, der B-Ebene Isolierung wicklungserw\u00e4rmung limit 80K, the F-Ebene Isolierung der Wicklung Temperaturanstieg zu begrenzen, ist 100K, und der H-Ebene Isolierung wicklungserw\u00e4rmung limit 125K.<\/p>\n<div class=\"pro-content\">\n<table>\n<tbody>\n<tr>\n<td>Isolierung Klasse<\/td>\n<td>maximum allowable temperature\uff08\u2103\uff09<\/td>\n<td>Wicklungserw\u00e4rmung limit \uff08K\uff09<\/td>\n<td>Leistung reference temperature\uff08\u2103\uff09<\/td>\n<\/tr>\n<tr>\n<td>Ein<\/td>\n<td>105<\/td>\n<td>60<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>E<\/td>\n<td>120<\/td>\n<td>75<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>B<\/td>\n<td>130<\/td>\n<td>80<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>F<\/td>\n<td>155<\/td>\n<td>100<\/td>\n<td>120<\/td>\n<\/tr>\n<tr>\n<td>H<\/td>\n<td>180<\/td>\n<td>125<\/td>\n<td>145<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2><strong>Zusammenfassung<\/strong><\/h2>\n<p>Der Isolationswert eines Transformators bestimmt seine W\u00e4rme Widerstand, und die Temperatur Aufstieg Begrenzung legt die maximal zul\u00e4ssige Temperaturdifferenz zwischen der Innenseite des Transformators und seiner Umgebung.<\/p>\n<h2 style=\"font-weight: bold;\">Kontakt<\/h2>\n<p>\u96fb\u529b\u306e\u7b97\u51fa: <a href=\"https:\/\/www.lstransformer.com\/de\/\">single-phase transformer, three-phase-isolation in Transformatoren, elektrischen Transformator, Verteilung Transformator, step-down und step-up-Transformator, low-Spannung Transformator, hohe Spannung Transformator, Steuerung, Transformator, Ringkern Transformator, R-core-Transformator; DC-Spulen, AC Reaktoren, Filter-Reaktor -, line-und load reactor, drosseln, Filter-Reaktor, und die Mittel, hoch-Frequenz-Produkte<\/a>.<\/p>\n<p>\u304cV_peak\u7a4d\u306e\u904e\u96fb\u5727\u306e\u30d4\u30fc\u30af\u3068t_res\u306b\u5171\u9cf4\u3002 30%\u30de\u30fc\u30b8\u30f3\u63a8\u5968\u3092\u5360\u3081\u308b\u30b7\u30b9\u30c6\u30e0\u30d1\u30e9\u30e1\u30fc\u30bf\u5316\u3057\u307e\u3059\u3002<\/p>\n<p>2.2.3\u306e\u52d5\u7684\u5fdc\u7b54\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3 <a href=\"https:\/\/www.lstransformer.com\/de\/\">\u73fe\u4ee3\u306e\u30b7\u30b9\u30c6\u30e0\u5229\u7528\u30b5\u30a4\u30ea\u30b9\u30bf\u5236\u5fa1\u306b\u3088\u308b\u62b5\u6297\u6e1b\u8870(TCRD)\u3092\u691c\u77e5\u3059\u308b\u5171\u9cf4\u518510ms\u3001\u914d\u306e\u6b63\u78ba\u6027\u3001\u5207\u65ad\u4e2d\u306e\u901a\u5e38\u306e\u64cd\u4f5c\u306f\u907f\u3051\u307e\u3059\u3002<\/a>.<\/p>\n<p>3. \u9023\u643a\u6a5f\u69cb\u306e\u30a2\u30af\u30c6\u30a3\u30d6\u30d5\u30a3\u30eb\u30bf<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\nE-Mail: marketing@hnlsdz.com<\/p>\n<p><iframe title=\"Was ist das realationship zwischen Isolierung Ebene und Temperatur Aufstieg standard?\" src=\"https:\/\/www.youtube.com\/embed\/03emGuzgN40\" width=\"956\" height=\"538\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\" data-mce-fragment=\"1\"><\/iframe><\/p>","protected":false},"excerpt":{"rendered":"<p>What is the relationship between transformer insulation level and temperature rise standard\uff1f Insulation level and temperature rise: The insulation level of a transformer refers to the maximum allowable temperature rise, which is the heat resistance level of the insulation material used in the transformer. The temperature rise, on the other hand, refers to the temperature [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2391,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1401","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Transformer Temperature Rise | LuShan<\/title>\n<meta name=\"description\" content=\"Learn how transformer insulation class relates to allowable temperature rise. Consider ambient temperature, loading and cooling when reviewing a transformer&#039;s thermal design.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/de\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard\uff1f\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Transformer Temperature Rise | LuShan\" \/>\n<meta property=\"og:description\" content=\"Learn how transformer insulation class relates to allowable temperature rise. Consider ambient temperature, loading and cooling when reviewing a transformer&#039;s thermal design.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/de\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard\uff1f\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:33:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-29T06:55:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742182413525452.png\" \/>\n\t<meta property=\"og:image:width\" content=\"370\" \/>\n\t<meta property=\"og:image:height\" content=\"276\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"3\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"What is the relationship between transformer insulation level and temperature rise standard\uff1f\",\"datePublished\":\"2026-07-22T05:33:19+00:00\",\"dateModified\":\"2026-10-29T06:55:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/\"},\"wordCount\":333,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1742182413525452.png\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/\",\"name\":\"Transformer Temperature Rise | LuShan\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1742182413525452.png\",\"datePublished\":\"2026-07-22T05:33:19+00:00\",\"dateModified\":\"2026-10-29T06:55:50+00:00\",\"description\":\"Learn how transformer insulation class relates to allowable temperature rise. Consider ambient temperature, loading and cooling when reviewing a transformer's thermal design.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1742182413525452.png\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1742182413525452.png\",\"width\":370,\"height\":276},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is the relationship between transformer insulation level and temperature rise standard\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/de\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Transformer Temperature Rise | LuShan","description":"Learn how transformer insulation class relates to allowable temperature rise. Consider ambient temperature, loading and cooling when reviewing a transformer's thermal design.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/de\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard\uff1f\/","og_locale":"de_DE","og_type":"article","og_title":"Transformer Temperature Rise | LuShan","og_description":"Learn how transformer insulation class relates to allowable temperature rise. Consider ambient temperature, loading and cooling when reviewing a transformer's thermal design.","og_url":"https:\/\/www.lstransformer.com\/de\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard\uff1f\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:33:19+00:00","article_modified_time":"2026-10-29T06:55:50+00:00","og_image":[{"width":370,"height":276,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742182413525452.png","type":"image\/png"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"369703005","Gesch\u00e4tzte Lesezeit":"3\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"What is the relationship between transformer insulation level and temperature rise standard\uff1f","datePublished":"2026-07-22T05:33:19+00:00","dateModified":"2026-10-29T06:55:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/"},"wordCount":333,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742182413525452.png","articleSection":["FAQ"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/","url":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/","name":"Transformer Temperature Rise | LuShan","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742182413525452.png","datePublished":"2026-07-22T05:33:19+00:00","dateModified":"2026-10-29T06:55:50+00:00","description":"Learn how transformer insulation class relates to allowable temperature rise. Consider ambient temperature, loading and cooling when reviewing a transformer's thermal design.","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742182413525452.png","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742182413525452.png","width":370,"height":276},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/what-is-the-relationship-between-transformer-insulation-level-and-temperature-rise-standard%ef%bc%9f\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"What is the relationship between transformer insulation level and temperature rise standard\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS power Transformator, die Linie Reaktor, Hohe-Spannung Transformator, \u00d6l-eingetaucht Transformator-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS power Transformator, die Linie Reaktor, Hohe-Spannung Transformator, \u00d6l-eingetaucht Transformator-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/de\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/comments?post=1401"}],"version-history":[{"count":4,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1401\/revisions"}],"predecessor-version":[{"id":6688,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/posts\/1401\/revisions\/6688"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/media\/2391"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/media?parent=1401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/categories?post=1401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/de\/wp-json\/wp\/v2\/tags?post=1401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}