{"id":1185,"date":"2026-07-22T05:32:59","date_gmt":"2026-07-22T05:32:59","guid":{"rendered":"https:\/\/lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/"},"modified":"2026-09-30T05:51:33","modified_gmt":"2026-09-30T05:51:33","slug":"how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/es\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/","title":{"rendered":"C\u00f3mo Manejar el Transformador de la Luz de Alarma de Gas? \u2014 Una Gu\u00eda Autorizada por el Mundial de Expertos en Mantenimiento"},"content":{"rendered":"<h1>C\u00f3mo Manejar el Transformador de la Luz de Alarma de Gas?<b><\/b><\/h1>\n<h4>\u2014 Una Gu\u00eda Autorizada por el Mundial de Expertos en Mantenimiento<b><\/b><\/h4>\n<p>La luz de alarma de gas en un transformador es una importante se\u00f1al de alerta temprana en sistemas de potencia. Como uno de los m\u00e1s esenciales de la no-el\u00e9ctrico de protecciones para transformadores, la activaci\u00f3n de la luz de gas de contacto de un rel\u00e9 Buchholz directamente indica anormal de generaci\u00f3n de gas en el interior del equipo. Ignorar o el mal manejo de esta alarma puede llevar a una aceleraci\u00f3n de la degradaci\u00f3n del aislamiento, culpa escondida de expansi\u00f3n, y en \u00faltima instancia costoso transformador de fallos o incluso accidentes catastr\u00f3ficos. Esta gu\u00eda, basada en la Comisi\u00f3n Electrot\u00e9cnica Internacional (IEC) 60599 y el Instituto de Ingenieros El\u00e9ctricos y Electr\u00f3nicos (IEEE) C57.104 normas, proporciona una clara, pr\u00e1ctica global el procedimiento de respuesta.<\/p>\n<h2><b><span style=\"font-family: Arial;\">Contenido<\/span><\/b><b><\/b><\/h2>\n<h3><em>1. La comprensi\u00f3n de los principios B\u00e1sicos de la Luz de Alarma de Gas: \u00bfpor Qu\u00e9 Son los Gases de Indicadores Clave?<\/em><b><\/b><\/h3>\n<p>Cuando el aislamiento de transformadores de materiales (tales como el aceite aislante y el aislamiento s\u00f3lido como el papel o cart\u00f3n prensado) se descompone bajo el\u00e9ctrico, t\u00e9rmico, mec\u00e1nico o estr\u00e9s, se producen varios culpa de los gases (Falta de efecto invernadero), incluyendo el hidr\u00f3geno (H\u2082), el metano (CH\u2084), etano (C\u2082H\u2086), etileno (C\u2082H\u2084), acetileno (C\u2082H\u2082), mon\u00f3xido de carbono (CO) y di\u00f3xido de carbono (CO\u2082). La tasa de producci\u00f3n y la composici\u00f3n de estos gases servir como un &#8220;de huellas dactilares&#8221; para identificar los tipos de fallos (descarga parcial, sobrecalentamiento, arcos) y su gravedad.<\/p>\n<p>El rel\u00e9 Buchholz est\u00e1 instalado en el aceite de la tuber\u00eda entre el tanque del transformador y el tutor. Cuando el gas se acumula lentamente en el rel\u00e9 de&#8217;s superior de la c\u00e1mara de gas, hace que el nivel de aceite a caer, finalmente, la activaci\u00f3n de la flotaci\u00f3n o el interruptor de l\u00e1minas para la luz de alarma de gas. Este proceso se dirige principalmente a la etapa temprana o faltas menores, con bajos \u00edndices de generaci\u00f3n de gas y que no han causado violento flujo de aceite de las perturbaciones.<\/p>\n<p><a title=\"Distribuidor, Mayorista de Transformadores de Suministros y los Fabricantes,que se Especializa en los Transformadores de 50 a\u00f1os\" href=\"https:\/\/www.lstransformer.com\/es\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter\" title=\"16\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1766476502163704.jpg\" alt=\"16\" width=\"400\" height=\"384\" border=\"0\" vspace=\"0\" \/><\/a><\/p>\n<h3><em>2. Las posibles Causas de la Luz de Alarma de Gas: De Com\u00fan a Severa<\/em><b><\/b><\/h3>\n<p>La comprensi\u00f3n de las causas es la base para la formulaci\u00f3n de contramedidas:<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>2.1 No culpa de la acumulaci\u00f3n de gas (m\u00e1s comunes):<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Aire residuo despu\u00e9s de llenado de aceite\/filtraci\u00f3n:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Tras la puesta en marcha o mantenimiento mayor, por aire disuelto o de aire residual en la c\u00e1mara de gas puede liberar lentamente. Tales gases consisten principalmente de nitr\u00f3geno (N\u2082) y ox\u00edgeno (O\u2082), con poca o ninguna culpa de los gases.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Aceite de descenso de la temperatura o el nivel de aceite disminuir:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Disminuci\u00f3n de la carga que conduce a la baja de la temperatura del aceite o de la normal de aceite de las fluctuaciones del nivel (por ejemplo, debido a la respiradero de la acci\u00f3n) puede liberar por aire disuelto, acumulando en el rel\u00e9. Esto es m\u00e1s com\u00fan en las regiones con un importante d\u00eda-noche o estacionales, variaciones de carga.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Menores de estanqueidad:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Peque\u00f1a presi\u00f3n negativa con fugas puede permitir que el aire poco a poco, ser dibujado en el transformador.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>2.2 etapa Temprana o de baja energ\u00eda fallos:<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Low-temperature overheating (&lt;150\u00b0C):<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Causada por el n\u00facleo de circulaci\u00f3n de las corrientes debido a la multi-punto de puesta a tierra, estructural de la corriente de foucault de calefacci\u00f3n, o suelto conexiones con pernos. Produce principalmente H\u2082, CH\u2084, y C\u2082H\u2086.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Medio-temperatura de sobrecalentamiento (150\u00b0C\u2013300\u00b0C):<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Causado por el aumento de la resistencia de contacto en los cambiadores, suelta la liquidaci\u00f3n de las conexiones o el bloqueo de canales de aceite. Produce principalmente H\u2082, CH\u2084, C\u2082H\u2084, y C\u2082H\u2086.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Bajo nivel de energ\u00eda de una descarga parcial:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Como la burbuja de descarga en el petr\u00f3leo, el gas brecha de descarga en el aislamiento de papel, o flotante potencial de descarga. Produce principalmente H\u2082 y peque\u00f1as cantidades de CH\u2084.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(4)Menor aislamiento s\u00f3lido envejecimiento:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Produce CO y CO \u2082 (indicativo de papel degradaci\u00f3n del aislamiento). Si va acompa\u00f1ado por el sobrecalentamiento, los gases de hidrocarburos tambi\u00e9n se pueden formar.<\/p>\n<table width=\"663\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"168\"><b>La Causa De La Categor\u00eda<\/b><\/td>\n<td valign=\"top\" width=\"219\"><b>Ejemplos T\u00edpicos<\/b><\/td>\n<td valign=\"top\" width=\"151\"><b>La Falla Principal De Los Gases De<\/b><\/td>\n<td valign=\"top\" width=\"124\"><b>Nivel De Riesgo<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">No falla<\/td>\n<td valign=\"top\" width=\"219\">Aceite de llenado de los residuos, la temperatura del aceite de la gota<\/td>\n<td valign=\"top\" width=\"151\">N\u2082, O \u2082 (relaci\u00f3n de altura)<\/td>\n<td valign=\"top\" width=\"124\">Baja<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">No falla<\/td>\n<td valign=\"top\" width=\"219\">Menores de estanqueidad (aire de entrada)<\/td>\n<td valign=\"top\" width=\"151\">N\u2082, O \u2082 (relaci\u00f3n de altura)<\/td>\n<td valign=\"top\" width=\"124\">Baja (necesita reparaci\u00f3n)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Principios de la culpa (el\u00e9ctrica\/t\u00e9rmica)<\/td>\n<td valign=\"top\" width=\"219\">Low-temperature overheating (&lt;150\u00b0C)<\/td>\n<td valign=\"top\" width=\"151\">H\u2082, CH\u2084, C\u2082H\u2086<\/td>\n<td valign=\"top\" width=\"124\">Medio<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Principios de la culpa (t\u00e9rmica)<\/td>\n<td valign=\"top\" width=\"219\">Medio de la temperatura de sobrecalentamiento (150\u00b0C\u2013300\u00b0C)<\/td>\n<td valign=\"top\" width=\"151\">H\u2082, CH\u2084, C\u2082H\u2084, C\u2082H\u2086<\/td>\n<td valign=\"top\" width=\"124\">Medio-alto<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">A principios de fallas (el\u00e9ctricas)<\/td>\n<td valign=\"top\" width=\"219\">Baja energ\u00eda de descargas parciales<\/td>\n<td valign=\"top\" width=\"151\">H\u2082, (traza CH\u2084)<\/td>\n<td valign=\"top\" width=\"124\">Medio-alto<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Principios de la culpa (aislamiento)<\/td>\n<td valign=\"top\" width=\"219\">Menor aislamiento s\u00f3lido envejecimiento\/sobrecalentamiento<\/td>\n<td valign=\"top\" width=\"151\">CO, CO\u2082 (mayor riesgo con hidrocarburos)<\/td>\n<td valign=\"top\" width=\"124\">Medio-alto<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"table-note\" style=\"text-align: center;\"><i>Tabla 1: Causas Comunes de Transformador de Luz de Alarma de Gas y Clave Culpa de los Gases de<\/i><\/div>\n<h3><em>3. Estandarizado Proceso de Respuesta: la Seguridad, el Diagn\u00f3stico, la Decisi\u00f3n (Siguiendo la norma IEC\/IEEE Mejores Pr\u00e1cticas)<\/em><b><\/b><\/h3>\n<p>Principio b\u00e1sico: Responder de inmediato, diagnosticar con precauci\u00f3n, evitar el error de c\u00e1lculo, y nunca se restablece a ciegas!<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>3.1 Paso 1: Confirmar la alarma y registro de los par\u00e1metros cr\u00edticos<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1) Compruebe la se\u00f1al:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">\u00a0Compruebe el rel\u00e9 de Buchholz para una luz de alarma de gas (indicado por local\/remoto de se\u00f1ales) y descartar las falsas alarmas (por ejemplo, suelto o terminales de contacto de rel\u00e9 de chatter)<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2) tecla de Registro de par\u00e1metros:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Nota: la hora de la alarma, el transformador de corriente de carga, aceite\/bobinado temperaturas, la temperatura ambiente, voltaje del sistema, y las recientes operaciones (por ejemplo, cambiador de ajustes).<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3) Inspeccionar el rel\u00e9:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Observar el volumen de gas (normalmente de 250-300 ml para la luz de alarma de gas) y el color (el aire es incoloro; la culpa de los gases puede aparecer de color gris, negro o inflamables). No ventilaci\u00f3n inmediatamente!<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>3.2 Paso 2: Completa la inspecci\u00f3n externa y el an\u00e1lisis preliminar de<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)el nivel de Aceite comprobar:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">\u00a0Aseg\u00farese de que el tutor de nivel de aceite es normal. Los niveles anormales pueden activar alarmas o empeorar los fallos.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Respiradero de verificaci\u00f3n:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Compruebe gel de s\u00edlice de color (azul = eficaces; rosa = humedad saturada) y la funci\u00f3n respiratoria. La obstrucci\u00f3n puede causar presi\u00f3n negativa de aire de entrada.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)P\u00e9rdida de la inspecci\u00f3n:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Examinar los sellos, v\u00e1lvulas, bridas y para el aceite de trazas o fugas.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(4)ruido Anormal de detecci\u00f3n:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">El uso de un estetoscopio para escuchar los sonidos internos (por ejemplo, &#8220;el siseo&#8221; descargas o &#8220;zumbido&#8221; de sobrecalentamiento).<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(5)Revisi\u00f3n de la DGA de la historia:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Comparar reciente An\u00e1lisis de Gas Disuelto (DGA) informes para evaluar gas tendencias y las tasas de producci\u00f3n.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>3.3 Paso 3: Cr\u00edtica a la acci\u00f3n de forma Segura recoger el gas y el petr\u00f3leo muestras<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)muestreo de Gas:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">El uso de una jeringa o de gas de la bolsa para recoger el gas desde el rel\u00e9 de la v\u00e1lvula de ventilaci\u00f3n (siga las pautas del fabricante). Evitar la contaminaci\u00f3n del aire o de ignici\u00f3n (acetileno es inflamable!). Registro de tiempo de muestreo y el volumen.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)toma de muestras de Aceite:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Recoger el aceite de la parte inferior de la v\u00e1lvula para la DGA an\u00e1lisis. Uso limpio, contenedores herm\u00e9ticos.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)pruebas de Laboratorio:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Enviar muestras a un IEC 60599 o ASTM D3612-laboratorio certificado por cromatograf\u00eda de gases (an\u00e1lisis de H\u2082, CH\u2084, C\u2082H\u2082, etc.).<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>3.4 Paso 4: la Toma de decisiones basada en los resultados del diagn\u00f3stico<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Resultado 1:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">En su mayor\u00eda con aire (N\u2082, O \u2082 &gt; 70%, el m\u00ednimo fallo de gases)Acci\u00f3n: Seguridad de ventilaci\u00f3n de gas, restablecer la alarma, direcci\u00f3n de fugas, y vigilar de cerca.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Resultado 2:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Culpa significativa de gases (H\u2082, hidrocarburos, CO)<\/p>\n<p style=\"padding-left: 40px;\">Acci\u00f3n: Reducir la carga, intensificar la supervisi\u00f3n, prepararse para el cierre, consultar a expertos, y programar las reparaciones.<\/p>\n<p><a title=\"Distribuidor, Mayorista de Transformadores de Suministros y los Fabricantes,que se Especializa en los Transformadores de 50 a\u00f1os\" href=\"https:\/\/www.lstransformer.com\/es\/Oil-immersedTransformer\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter\" title=\"13\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1766476466221765.jpg\" alt=\"13\" width=\"400\" height=\"384\" border=\"0\" vspace=\"0\" \/><\/a><\/p>\n<h3><em>4. Estrategias preventivas para la Luz de alarma de Gas<\/em><b><\/b><\/h3>\n<p style=\"padding-left: 40px;\"><strong><span style=\"color: #4874cb;\">(1)<\/span><\/strong> Regulares de monitoreo de la DGA (en consonancia con la norma IEC\/IEEE standards).<\/p>\n<p style=\"padding-left: 40px;\"><strong><span style=\"color: #4874cb;\">(2)<\/span><\/strong> Mantenimiento basado en el estado (CBM)el uso de la DGA tendencias y monitoreo en l\u00ednea.<\/p>\n<p style=\"padding-left: 40px;\"><strong><span style=\"color: #4874cb;\">(3)<\/span><\/strong> Strict1Oilhandling procedimientos (desgasificaci\u00f3n al vac\u00edo \/ deshidrataci\u00f3n seg\u00fan IEC 60422).<\/p>\n<p style=\"padding-left: 40px;\"><strong><span style=\"color: #4874cb;\">(4)<\/span> <\/strong>Sello de la integridad de mantenimiento (compruebe las juntas, respira, dispositivos de alivio de presi\u00f3n).<\/p>\n<p style=\"padding-left: 40px;\"><strong><span style=\"color: #4874cb;\">(5)<\/span> <\/strong>Mejorado de control operativo (aceite\/bobinado temperaturas, corrientes de carga).<\/p>\n<h2><b><span style=\"font-family: Arial;\">En Resumen<\/span><\/b><\/h2>\n<p>Una luz de alarma de gas es vital &#8220;indicador de la salud&#8221; para transformadores. Despu\u00e9s de este IEC\/IEEE-proceso\u2014respuesta inmediata, inspecci\u00f3n minuciosa, precisa de muestreo, an\u00e1lisis de expertos, y las decisiones basadas en los datos\u2014puede evitar que los peque\u00f1os problemas de la escalada. Proactivo DGA monitoreo y mantenimiento preventivo son la clave para la fiabilidad.<\/p>\n<h2 style=\"font-weight: bold;\"><strong>Contacto<\/strong><\/h2>\n<p>LuShan, est. En 1975, es un Chino fabricante profesional que se especializa en los transformadores de potencia y reactores de m\u00e1s de 50 a\u00f1os. Los productos principales son <a href=\"https:\/\/www.lstransformer.com\/es\/\">transformador monof\u00e1sico, trif\u00e1sico de transformadores de aislamiento, transformador el\u00e9ctrico, transformador de distribuci\u00f3n, el paso hacia abajo y paso transformador de baja tensi\u00f3n del transformador, transformador de alto voltaje, transformador de control, transformador toroidal, R-transformador con n\u00facleo; DC inductores, CA reactores, filtrado de reactor de l\u00ednea y de carga del reactor, estrangulaciones, el filtrado de los reactores y de los intermedios, de alta frecuencia de los productos<\/a>.<\/p>\n<p>Nuestros transformadores de potencia y reactores son ampliamente utilizados en las 10 \u00e1reas de aplicaci\u00f3n: rapid transit, maquinaria de construcci\u00f3n, energ\u00eda renovable, de fabricaci\u00f3n inteligentes, equipos m\u00e9dicos, la mina de carb\u00f3n de la explosi\u00f3n de la prevenci\u00f3n, el sistema de excitaci\u00f3n, de vac\u00edo, de sinterizaci\u00f3n(horno), aire acondicionado central.<\/p>\n<p>Saber m\u00e1s acerca de transformadores de potencia y reactores: <a href=\"https:\/\/www.lstransformer.com\/es\/\">www.lstransformer.com<\/a>.<\/p>\n<p>Si desea obtener soluciones personalizadas para transformadores o reactores, p\u00f3ngase en contacto con nosotros.<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\nCorreo electr\u00f3nico: marketing@hnlsdz.com<\/p>","protected":false},"excerpt":{"rendered":"<p>How to Handle Transformer Light Gas Alarm? \u2014 An Authoritative Guide by Global Maintenance Experts The light gas alarm in a transformer is a critical early warning signal in power systems. As one of the most essential non-electrical protections for transformers, the activation of the light gas contact in a Buchholz relay directly indicates abnormal [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":3289,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1185","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Handle Transformer Light Gas Alarm? \u2014 An Authoritative Guide by Global Maintenance Experts - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD<\/title>\n<meta name=\"description\" content=\"The light gas alarm in a transformer is a critical early warning signal in power systems. As one of the most essential non-electrical protections for transformers, the activation of the light gas contact in a Buchholz relay directly indicates abnormal gas generation inside the equipment. Ignoring or mishandling this alarm can lead to accelerated insulation degradation, latent fault expansion, and ultimately costly transformer failures or even catastrophic accidents. This guide, based on the International Electrotechnical Commission (IEC) 60599 and the Institute of Electrical and Electronics Engineers (IEEE) C57.104 standards, provides a clear, actionable global response procedure.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/es\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Handle Transformer Light Gas Alarm? \u2014 An Authoritative Guide by Global Maintenance Experts - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"og:description\" content=\"The light gas alarm in a transformer is a critical early warning signal in power systems. As one of the most essential non-electrical protections for transformers, the activation of the light gas contact in a Buchholz relay directly indicates abnormal gas generation inside the equipment. Ignoring or mishandling this alarm can lead to accelerated insulation degradation, latent fault expansion, and ultimately costly transformer failures or even catastrophic accidents. This guide, based on the International Electrotechnical Commission (IEC) 60599 and the Institute of Electrical and Electronics Engineers (IEEE) C57.104 standards, provides a clear, actionable global response procedure.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/es\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:32:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-30T05:51:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1766476593220034.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"370\" \/>\n\t<meta property=\"og:image:height\" content=\"276\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"How to Handle Transformer Light Gas Alarm? \u2014 An Authoritative Guide by Global Maintenance Experts\",\"datePublished\":\"2026-07-22T05:32:59+00:00\",\"dateModified\":\"2026-09-30T05:51:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/\"},\"wordCount\":1160,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1766476593220034.jpg\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/\",\"name\":\"How to Handle Transformer Light Gas Alarm? \u2014 An Authoritative Guide by Global Maintenance Experts - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1766476593220034.jpg\",\"datePublished\":\"2026-07-22T05:32:59+00:00\",\"dateModified\":\"2026-09-30T05:51:33+00:00\",\"description\":\"The light gas alarm in a transformer is a critical early warning signal in power systems. As one of the most essential non-electrical protections for transformers, the activation of the light gas contact in a Buchholz relay directly indicates abnormal gas generation inside the equipment. Ignoring or mishandling this alarm can lead to accelerated insulation degradation, latent fault expansion, and ultimately costly transformer failures or even catastrophic accidents. This guide, based on the International Electrotechnical Commission (IEC) 60599 and the Institute of Electrical and Electronics Engineers (IEEE) C57.104 standards, provides a clear, actionable global response procedure.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1766476593220034.jpg\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1766476593220034.jpg\",\"width\":370,\"height\":276},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Handle Transformer Light Gas Alarm? \u2014 An Authoritative Guide by Global Maintenance Experts\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/es\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"C\u00f3mo Manejar el Transformador de la Luz de Alarma de Gas? \u2014 Una Gu\u00eda Autorizada por el Mundial de Expertos en Mantenimiento - LS transformador de potencia, reactor de L\u00ednea de Alta tensi\u00f3n del transformador, el Aceite de transformador inmerso-CHANGSHA LUSHAN TECNOLOG\u00cdA ELECTR\u00d3NICA CO.,LTD","description":"La luz de alarma de gas en un transformador es una importante se\u00f1al de alerta temprana en sistemas de potencia. Como uno de los m\u00e1s esenciales de la no-el\u00e9ctrico de protecciones para transformadores, la activaci\u00f3n de la luz de gas de contacto de un rel\u00e9 Buchholz directamente indica anormal de generaci\u00f3n de gas en el interior del equipo. Ignorar o el mal manejo de esta alarma puede llevar a una aceleraci\u00f3n de la degradaci\u00f3n del aislamiento, culpa escondida de expansi\u00f3n, y en \u00faltima instancia costoso transformador de fallos o incluso accidentes catastr\u00f3ficos. Esta gu\u00eda, basada en la Comisi\u00f3n Electrot\u00e9cnica Internacional (IEC) 60599 y el Instituto de Ingenieros El\u00e9ctricos y Electr\u00f3nicos (IEEE) C57.104 normas, proporciona una clara, pr\u00e1ctica global el procedimiento de respuesta.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/es\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/","og_locale":"es_ES","og_type":"article","og_title":"How to Handle Transformer Light Gas Alarm? \u2014 An Authoritative Guide by Global Maintenance Experts - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","og_description":"The light gas alarm in a transformer is a critical early warning signal in power systems. As one of the most essential non-electrical protections for transformers, the activation of the light gas contact in a Buchholz relay directly indicates abnormal gas generation inside the equipment. Ignoring or mishandling this alarm can lead to accelerated insulation degradation, latent fault expansion, and ultimately costly transformer failures or even catastrophic accidents. This guide, based on the International Electrotechnical Commission (IEC) 60599 and the Institute of Electrical and Electronics Engineers (IEEE) C57.104 standards, provides a clear, actionable global response procedure.","og_url":"https:\/\/www.lstransformer.com\/es\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:32:59+00:00","article_modified_time":"2026-09-30T05:51:33+00:00","og_image":[{"width":370,"height":276,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1766476593220034.jpg","type":"image\/jpeg"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"369703005","Tiempo de lectura":"7 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"How to Handle Transformer Light Gas Alarm? \u2014 An Authoritative Guide by Global Maintenance Experts","datePublished":"2026-07-22T05:32:59+00:00","dateModified":"2026-09-30T05:51:33+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/"},"wordCount":1160,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1766476593220034.jpg","articleSection":["FAQ"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/","url":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/","name":"C\u00f3mo Manejar el Transformador de la Luz de Alarma de Gas? \u2014 Una Gu\u00eda Autorizada por el Mundial de Expertos en Mantenimiento - LS transformador de potencia, reactor de L\u00ednea de Alta tensi\u00f3n del transformador, el Aceite de transformador inmerso-CHANGSHA LUSHAN TECNOLOG\u00cdA ELECTR\u00d3NICA CO.,LTD","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1766476593220034.jpg","datePublished":"2026-07-22T05:32:59+00:00","dateModified":"2026-09-30T05:51:33+00:00","description":"La luz de alarma de gas en un transformador es una importante se\u00f1al de alerta temprana en sistemas de potencia. Como uno de los m\u00e1s esenciales de la no-el\u00e9ctrico de protecciones para transformadores, la activaci\u00f3n de la luz de gas de contacto de un rel\u00e9 Buchholz directamente indica anormal de generaci\u00f3n de gas en el interior del equipo. Ignorar o el mal manejo de esta alarma puede llevar a una aceleraci\u00f3n de la degradaci\u00f3n del aislamiento, culpa escondida de expansi\u00f3n, y en \u00faltima instancia costoso transformador de fallos o incluso accidentes catastr\u00f3ficos. Esta gu\u00eda, basada en la Comisi\u00f3n Electrot\u00e9cnica Internacional (IEC) 60599 y el Instituto de Ingenieros El\u00e9ctricos y Electr\u00f3nicos (IEEE) C57.104 normas, proporciona una clara, pr\u00e1ctica global el procedimiento de respuesta.","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1766476593220034.jpg","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1766476593220034.jpg","width":370,"height":276},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/how-to-handle-transformer-light-gas-alarm-an-authoritative-guide-by-global-maintenance-experts\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"How to Handle Transformer Light Gas Alarm? \u2014 An Authoritative Guide by Global Maintenance Experts"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS transformador de potencia, reactor de L\u00ednea de Alta tensi\u00f3n del transformador, el Aceite de transformador inmerso-CHANGSHA LUSHAN TECNOLOG\u00cdA ELECTR\u00d3NICA CO.,LTD","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS transformador de potencia, reactor de L\u00ednea de Alta tensi\u00f3n del transformador, el Aceite de transformador inmerso-CHANGSHA LUSHAN TECNOLOG\u00cdA ELECTR\u00d3NICA CO.,LTD","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/es\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/posts\/1185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/comments?post=1185"}],"version-history":[{"count":7,"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/posts\/1185\/revisions"}],"predecessor-version":[{"id":7190,"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/posts\/1185\/revisions\/7190"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/media\/3289"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/media?parent=1185"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/categories?post=1185"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/es\/wp-json\/wp\/v2\/tags?post=1185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}