{"id":1163,"date":"2026-07-22T05:32:58","date_gmt":"2026-07-22T05:32:58","guid":{"rendered":"https:\/\/lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/"},"modified":"2026-10-29T06:55:24","modified_gmt":"2026-10-29T06:55:24","slug":"how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/fr\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/","title":{"rendered":"Comment Choisir le Terminal de Configurations pour les Transformateurs et les R\u00e9acteurs Bas\u00e9s sur l'estimation Actuelle?"},"content":{"rendered":"<h1>Comment Choisir le Terminal de Configurations pour les Transformateurs et les R\u00e9acteurs Bas\u00e9s sur l'estimation Actuelle?<b><\/b><\/h1>\n<p>Dans la conception et l'application des transformateurs et des r\u00e9acteurs, le choix de la configuration du terminal influe directement sur les performances de l'\u00e9quipement, de la s\u00e9curit\u00e9, et la dur\u00e9e de vie. Pour les diff\u00e9rentes cotes de cr\u00e9dit actuelles, les ing\u00e9nieurs doivent tenir compte de facteurs comme le conducteur de courant admissible, les effets thermiques et de compatibilit\u00e9 \u00e9lectromagn\u00e9tique. Cet article analyse syst\u00e9matiquement la fa\u00e7on dont le courant nominal des influences de la configuration du terminal de s\u00e9lection, couvrant les sc\u00e9narios de la basse tension\/courant faible \u00e0 haute tension\/haute-applications actuelles. Le r\u00e9f\u00e9rencement des normes internationales telles que la CEI 60076 et IEEE C57, il fournit des informations pr\u00e9cieuses pour vous aider \u00e0 faire globalement conforme des d\u00e9cisions techniques.<\/p>\n<h2><b><span style=\"font-family: Arial;\">Contenu<\/span><\/b><b><\/b><\/h2>\n<h3><em>1. Relation fondamentale Entre le Courant nominal et le Terminal Configurations<\/em><b><\/b><\/h3>\n<h6 style=\"padding-left: 40px;\"><strong>(1) les Effets Thermiques et Section des Conducteurs<\/strong><i><\/i><\/h6>\n<p style=\"padding-left: 40px; text-align: left;\">Lorsque le courant circule dans un conducteur, chauffage par effet Joule se produit en raison de la r\u00e9sistance \u00e9lectrique. La chaleur produite (Q) est exprim\u00e9 comme suit:<\/p>\n<p style=\"padding-left: 40px; text-align: center;\"><b>Q = I2Rt<\/b><\/p>\n<p style=\"padding-left: 40px;\">O\u00f9:<\/p>\n<p style=\"padding-left: 40px;\">Q: Chaleur g\u00e9n\u00e9r\u00e9e (en Joules)<\/p>\n<p style=\"padding-left: 40px;\">I: Courant (Amp\u00e8res)<\/p>\n<p style=\"padding-left: 40px;\">R: le Chef d'orchestre de la r\u00e9sistance (en Ohms)<\/p>\n<p style=\"padding-left: 40px;\">t: Temps (en secondes)<i><\/i><\/p>\n<p style=\"padding-left: 40px;\">Cette formule montre que la production de chaleur est proportionnelle au carr\u00e9 du courant. De forte intensit\u00e9, les chefs d'orchestre avec suffisamment de surface de section transversale sont essentielles pour \u00e9viter la surchauffe. Conform\u00e9ment \u00e0 la norme CEI 60287, le courant admissible des conducteurs en cuivre \u00e0 l'air libre (30\u00b0C de la temp\u00e9rature ambiante) est:<\/p>\n<table cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"250\"><b>Cross-Section (mm2)<\/b><\/td>\n<td valign=\"top\"><b>Continu Courant Nominal (A)<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"250\">10<\/td>\n<td valign=\"top\">70<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"250\">25<\/td>\n<td valign=\"top\">110<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"250\">50<\/td>\n<td valign=\"top\">160<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"250\">100<\/td>\n<td valign=\"top\">250<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"table-note\" style=\"text-align: center;\"><i>Tableau 1: capacit\u00e9 des conducteurs de cuivre \u00e0 diff\u00e9rentes sections.<\/i><\/div>\n<h6 style=\"padding-left: 40px;\"><strong>(2) l'Effet de Peau et Terminal de Conception<\/strong><i><\/i><\/h6>\n<p style=\"padding-left: 40px;\">\u00c0 des fr\u00e9quences plus \u00e9lev\u00e9es ou des courants, l'Effet de Peau causes de courant AC de se concentrer \u00e0 proximit\u00e9 du conducteur de la surface. L'\u00e9paisseur de peau (\u03b4) est calcul\u00e9 comme suit:<\/p>\n<p style=\"padding-left: 40px; text-align: center;\"><b>\u03b4 = \u221a(\u03c1\/nf\u00b5)<\/b><\/p>\n<p style=\"padding-left: 40px; text-align: left;\">O\u00f9:<\/p>\n<p style=\"padding-left: 40px;\">r: R\u00e9sistivit\u00e9 (\u03a9\u00b7m)<\/p>\n<p style=\"padding-left: 40px;\">f: Fr\u00e9quence (Hz)<\/p>\n<p style=\"padding-left: 40px;\">\u03bc: Perm\u00e9abilit\u00e9 (H\/m)<i><\/i><\/p>\n<p style=\"padding-left: 40px;\">Pour 50 hz de la fr\u00e9quence d'alimentation, le cuivre de l'\u00e9paisseur de peau est ~9.3 mm. Ainsi, des conducteurs solides devenir inefficace pour des courants \u00e9lev\u00e9s. Au lieu de cela, les fils d\u00e9nud\u00e9s ou les creux tubulaire dessins sont privil\u00e9gi\u00e9es. Par exemple, des courants, 2000A souvent l'utilisation parall\u00e8le des barres de cuivre ou creux conducteurs \u00e0 optimiser la distribution de courant.<\/p>\n<p><a title=\"Transformateur, de Gros Transformateurs de Fournitures et de Fabricants,Sp\u00e9cialis\u00e9e dans les Transformateurs pour les 50 ans et +\" href=\"https:\/\/www.lstransformer.com\/fr\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter\" title=\"3eb0c0f4491d706dc0bb7cc8164dcb51\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1772377059666046.jpg\" alt=\"3eb0c0f4491d706dc0bb7cc8164dcb51\" \/><\/a><\/p>\n<h3><em>2. La Configuration du Terminal de S\u00e9lection par Plage de Courant<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><strong>2.1 Low Current (&lt;100A) Solutions<\/strong><i><\/i><\/h4>\n<p style=\"padding-left: 40px;\">Pour les applications faible courant, de fiabilit\u00e9 et de co\u00fbt-efficacit\u00e9 sont les cl\u00e9s:<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Bras\u00e9s:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">\u00a0Permanent connections (e.g., copper\/silver solder) offer ultra-low contact resistance (&lt;10\u03bc\u03a9) but are non-detachable.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Boulonn\u00e9 Terminaux:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">M6-M10 bolts secure terminals to windings. Surface roughness (&lt;3.2\u03bcm Ra) and anti-oxidant grease (e.g., Dow Corning\u00ae DC-4) reduce contact resistance by 40%.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Serties De Terminaux:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Hydraulique de sertissage \u00e9vite les zones affect\u00e9es par la chaleur, id\u00e9al pour l'aluminium. Conform\u00e9ment \u00e0 la norme CEI 61238, l'ondulation doit r\u00e9sister \u00e0+ de 100 cycles thermiques (de -40\u00b0C \u00e0 +120\u00b0C) sans r\u00e9sistance \u00e0 la d\u00e9gradation.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>2.2 Moyenne de Courant (100\u20131000A) des Solutions<\/strong><i><\/i><\/h4>\n<p style=\"padding-left: 40px;\">Thermique et \u00e9lectromagn\u00e9tique de gestion devient critique:<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Multi-Terminal De Conception En Parall\u00e8le:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Le fractionnement du courant \u00e0 travers 4+ terminaux (par exemple, vis M12) r\u00e9duit par point de chauffage par 1\/16. Les Tests montrent 25K moindre \u00e9l\u00e9vation de temp\u00e9rature dans le 500A applications.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Refroidi \u00c0 L'Eau De Terminaux:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Integrated coolant channels (deionized water, conductivity &lt;5\u03bcS\/cm) boost ampacity by 30\u201350%. Real-world data shows 40\u00b0C lower temperatures at 800A vs. air-cooled designs.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Mat\u00e9riaux \u00c0 Changement De Phase (Pcm):<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">\u00a0La paraffine \u00e0 base de Mcp absorber la surcharge de chaleur (200\u2013300kJ\/kg). Au cours de 200% les surcharges, les Mcp limiter l'augmentation de la temp\u00e9rature de 50% des constructions traditionnelles.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>2.3 Courant \u00c9lev\u00e9 (&gt;1000A) des Solutions<\/strong><i><\/i><\/h4>\n<p style=\"padding-left: 40px;\">Abordant les forces \u00e9lectromagn\u00e9tiques et de l'expansion thermique:<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Tubulaire Coaxial Conducteurs:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Des tubes creux avec des contre-courants annuler 70 \u00e0 80% des forces de Lorentz F=BIl). Des essais de vibrations montrer \u00e0 60% inf\u00e9rieur \u00e0 l'amplitude de vs \u00e0 plat les jeux de barres.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Segment\u00e9 Isolation Obstacles:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">\u00c9poxy-verre barri\u00e8res entre les phases d'augmentation de la d\u00e9charge partielle de cr\u00e9ation de tension de 30 \u00e0 40% (selon la Loi de Paschen).<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Actif Magn\u00e9tique De Compensation:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">\u00a0Capteurs contr\u00f4l\u00e9s par des enroulements de la balance des champs (\u00b11% de l'homog\u00e9n\u00e9it\u00e9), la coupe des pertes par courant de foucault de 80%. Dans le monde r\u00e9el transformateurs CCHT enregistrer ~de 12 000 kWh\/an.<\/p>\n<p><a title=\"Transformateur, de Gros Transformateurs de Fournitures et de Fabricants,Sp\u00e9cialis\u00e9e dans les Transformateurs pour les 50 ans et +\" href=\"https:\/\/www.lstransformer.com\/fr\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter\" title=\"cc2d63ab2ba7be1095908b04532e5b04\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1772377016251114.jpg\" alt=\"cc2d63ab2ba7be1095908b04532e5b04\" \/><\/a><\/p>\n<h3><em>3. Sp\u00e9cial Consid\u00e9rations D'Application<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><strong>3.1 Haute Fr\u00e9quence et d'intensit\u00e9 \u00c9lev\u00e9e (par exemple, SMPS, Fours \u00e0 Induction)<\/strong><i><\/i><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Litz Les Bornes Des Fils:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Hundreds of insulated strands (each &lt;2\u00d7 skin depth) reduce AC resistance by 3\u20135x. Example: At 100kHz, 5mm\u00b2 Litz wire has 0.5m\u03a9\/m vs. 1.8m\u03a9\/m for solid wire.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Couches De Terminaux:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Empil\u00e9s 0,1 mm feuilles de cuivre avec polyimide isolation r\u00e9duire les pertes par 15-25% \u00e0 20\u2013100kHz.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>3.2 DC+AC Mixte Actuel (par exemple, les vfd, HVDC Vannes)<\/strong><i><\/i><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Contacts Nickel\u00e9s:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">\u226550\u03bcm nickel coatings suppress electrolytic corrosion (&lt;1\u03bcm\/year vs. 10\u201315\u03bcm for bare copper).<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>Hybride (2)Isolation:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Caoutchouc de Silicone (AC performances) + \u00e9poxy (DC force) r\u00e9duit la d\u00e9charge partielle de 50% de l'\u00e9olien en mer des convertisseurs.<\/p>\n<h2><b><span style=\"font-family: Arial;\">En R\u00e9sum\u00e9<\/span><\/b><\/h2>\n<p>Transformer and reactor terminal configurations must align with current rating, frequency, cooling needs, and mechanical stress. Low currents (&lt;100A) suit soldered\/bolted terminals, medium currents (100\u20131000A) demand multi-terminal or cooled designs, while high currents (&gt;1000A) require coaxial conductors or active compensation. High-frequency applications benefit from Litz wires, and DC+AC mixes need corrosion-resistant coatings. Always comply with IEC\/IEEE standards and validate designs via simulation\/testing.<\/p>\n<h2><strong>Contact<\/strong><\/h2>\n<p>LuShan, heure de l'est. 1975, est un fabricant professionnel Chinois sp\u00e9cialis\u00e9 dans les transformateurs de puissance et des r\u00e9acteurs de plus de 50 ans. Les produits de pointe sont <a href=\"https:\/\/www.lstransformer.com\/fr\/\">transformateur monophas\u00e9, triphas\u00e9 transformateurs d'isolement, transformateur \u00e9lectrique, transformateur de distribution, l'\u00e9tape vers le bas et d'intensifier le transformateur de basse tension du transformateur, transformateur \u00e0 haute tension, contr\u00f4le de transformateur toro\u00efdal transformateur, transformateur R-core; inductances DC, AC r\u00e9acteurs, le filtrage du r\u00e9acteur, de ligne et de charge du r\u00e9acteur, des bobines, le filtrage du r\u00e9acteur, et interm\u00e9diaire, \u00e0 haute fr\u00e9quence produits<\/a>.<\/p>\n<p>Nos transformateurs de puissance et les r\u00e9acteurs sont largement utilis\u00e9s dans les 10 domaines d'application: transport en commun rapide, les machines de construction, les \u00e9nergies renouvelables, intelligents de fabrication, des \u00e9quipements m\u00e9dicaux, de la mine de charbon de l'explosion de la pr\u00e9vention, de l'excitation du syst\u00e8me, frittage sous vide(four), d'une climatisation centrale.<\/p>\n<p>En savoir plus sur transformateur de puissance et le r\u00e9acteur: <a href=\"https:\/\/www.lstransformer.com\/fr\/\">www.lstransformer.com<\/a>.<\/p>\n<p>Si vous souhaitez obtenir des solutions personnalis\u00e9es pour les transformateurs ou des r\u00e9acteurs, veuillez nous contacter.<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\nE-mail: marketing@hnlsdz.com<\/p>","protected":false},"excerpt":{"rendered":"<p>How to Choose Terminal Configurations for Transformers and Reactors Based on Current Rating? In the design and application of transformers and reactors, the choice of terminal configuration directly impacts equipment performance, safety, and service life. For different current ratings, engineers must consider factors such as conductor ampacity, thermal effects, and electromagnetic compatibility. This article systematically [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":3341,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1163","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Terminal Configurations Transformers Reactors Based | LuShan<\/title>\n<meta name=\"description\" content=\"For different current ratings, engineers must consider factors such as conductor ampacity, thermal effects, and electromagnetic compatibility.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/fr\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Terminal Configurations Transformers Reactors Based | LuShan\" \/>\n<meta property=\"og:description\" content=\"For different current ratings, engineers must consider factors such as conductor ampacity, thermal effects, and electromagnetic compatibility.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/fr\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:32:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-29T06:55:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772377129280022.png\" \/>\n\t<meta property=\"og:image:width\" content=\"370\" \/>\n\t<meta property=\"og:image:height\" content=\"276\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"How to Choose Terminal Configurations for Transformers and Reactors Based on Current Rating?\",\"datePublished\":\"2026-07-22T05:32:58+00:00\",\"dateModified\":\"2026-10-29T06:55:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/\"},\"wordCount\":819,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1772377129280022.png\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/\",\"name\":\"Terminal Configurations Transformers Reactors Based | LuShan\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1772377129280022.png\",\"datePublished\":\"2026-07-22T05:32:58+00:00\",\"dateModified\":\"2026-10-29T06:55:24+00:00\",\"description\":\"For different current ratings, engineers must consider factors such as conductor ampacity, thermal effects, and electromagnetic compatibility.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1772377129280022.png\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1772377129280022.png\",\"width\":370,\"height\":276},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Choose Terminal Configurations for Transformers and Reactors Based on Current Rating?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Terminal Configurations Transformers Reactors Based | LuShan","description":"For different current ratings, engineers must consider factors such as conductor ampacity, thermal effects, and electromagnetic compatibility.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/fr\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/","og_locale":"fr_FR","og_type":"article","og_title":"Terminal Configurations Transformers Reactors Based | LuShan","og_description":"For different current ratings, engineers must consider factors such as conductor ampacity, thermal effects, and electromagnetic compatibility.","og_url":"https:\/\/www.lstransformer.com\/fr\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:32:58+00:00","article_modified_time":"2026-10-29T06:55:24+00:00","og_image":[{"width":370,"height":276,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772377129280022.png","type":"image\/png"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"369703005","Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"How to Choose Terminal Configurations for Transformers and Reactors Based on Current Rating?","datePublished":"2026-07-22T05:32:58+00:00","dateModified":"2026-10-29T06:55:24+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/"},"wordCount":819,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772377129280022.png","articleSection":["FAQ"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/","url":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/","name":"Terminal Configurations Transformers Reactors Based | LuShan","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772377129280022.png","datePublished":"2026-07-22T05:32:58+00:00","dateModified":"2026-10-29T06:55:24+00:00","description":"For different current ratings, engineers must consider factors such as conductor ampacity, thermal effects, and electromagnetic compatibility.","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772377129280022.png","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772377129280022.png","width":370,"height":276},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/how-to-choose-terminal-configurations-for-transformers-and-reactors-based-on-current-rating\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"How to Choose Terminal Configurations for Transformers and Reactors Based on Current Rating?"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS transformateur de puissance, r\u00e9acteur de Ligne \u00e0 Haute tension transformateur d'Huile de transformateur immerg\u00e9-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS transformateur de puissance, r\u00e9acteur de Ligne \u00e0 Haute tension transformateur d'Huile de transformateur immerg\u00e9-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/fr\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts\/1163","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/comments?post=1163"}],"version-history":[{"count":5,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts\/1163\/revisions"}],"predecessor-version":[{"id":6245,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts\/1163\/revisions\/6245"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/media\/3341"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/media?parent=1163"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/categories?post=1163"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/tags?post=1163"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}