{"id":1170,"date":"2026-07-22T05:32:59","date_gmt":"2026-07-22T05:32:59","guid":{"rendered":"https:\/\/lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/"},"modified":"2026-09-23T07:10:25","modified_gmt":"2026-09-23T07:10:25","slug":"oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/fr\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/","title":{"rendered":"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes"},"content":{"rendered":"<h1>Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes<b><\/b><\/h1>\n<p>Transformers are the core equipment of power systems, and the sealing process of their leads directly impacts the reliability and safety of operation. This article provides an in-depth analysis of the fundamental differences in lead sealing processes between oil-immersed and dry-type transformers, offering a professional interpretation from multiple dimensions, including materials science, structural design, and process standards.<\/p>\n<h2><b><span style=\"font-family: Arial;\">Contenu<\/span><\/b><b><\/b><\/h2>\n<h3><em>1.\u00a0Engineering Implementation of Lead Sealing in Oil-Immersed Transformers<\/em><\/h3>\n<h4 style=\"padding-left: 40px;\">1.1 Hierarchical Structure of the Sealing System<i><\/i><\/h4>\n<p style=\"padding-left: 40px;\">The lead sealing in oil-immersed transformers is a typical composite sealing system, consisting of three critical layers:<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Primary Sealing Layer:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">High-density nitrile rubber (NBR) O-rings with a Shore hardness of 70\u00b15, ensuring elasticity within a working temperature range of -40\u00b0C to 120\u00b0C.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Secondary Sealing Layer:\u00a0<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">Metal spiral wound gaskets, typically made of 304 stainless steel strips interleaved with flexible graphite, with a compression rate maintained at 18%-22%.<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Ultimate Sealing Layer:<\/strong><\/h6>\n<p style=\"padding-left: 80px;\">A spring-loaded mechanical sealing device with a preload force designed at 1.5 times the operating pressure.<\/p>\n<p style=\"padding-left: 40px;\">This three-tier sealing structure complies with the Class B sealing requirements of the ASME PCC-1 standard, ensuring a leakage rate of less than 5 ppm under 0.5 MPa oil pressure for 10 years.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>1.2 Scientific Material Selection<\/strong><i><\/i><\/h4>\n<p style=\"padding-left: 40px;\">The performance evaluation of sealing materials for oil-immersed transformers uses the Arrhenius accelerated aging model:<\/p>\n<p style=\"padding-left: 80px; text-align: center;\"><b>Aging rate constant k = A\u00b7e^(-Ea\/RT)<\/b><\/p>\n<p style=\"padding-left: 40px;\">O\u00f9:<\/p>\n<p style=\"padding-left: 80px;\">A: Pre-exponential factor (material constant)<\/p>\n<p style=\"padding-left: 80px;\">Ea: Activation energy (kJ\/mol)<\/p>\n<p style=\"padding-left: 80px;\">R: Ideal gas constant (8.314 J\/mol\u00b7K)<\/p>\n<p style=\"padding-left: 80px;\">T: Absolute temperature (K)<\/p>\n<p style=\"padding-left: 40px;\">Experimental data show that fluorocarbon rubber (FKM) has an Ea value of 85 kJ\/mol in transformer oil, significantly outperforming nitrile rubber (65 kJ\/mol), which is why FKM is preferred for high-end transformers.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>1.3 Key Process Control Parameters<\/strong><i><\/i><\/h4>\n<p style=\"padding-left: 40px;\">The sealing process for oil-immersed transformers requires strict control of the following parameters:<\/p>\n<table width=\"611\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"187\">Process Parameter<\/td>\n<td valign=\"top\">Control Range<\/td>\n<td valign=\"top\" width=\"239\">M\u00e9thode D'Essai<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"187\">Flange Flatness<\/td>\n<td valign=\"top\">\u22640.05 mm\/m<\/td>\n<td valign=\"top\" width=\"239\">Laser Flatness Tester<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"187\">Surface Roughness<\/td>\n<td valign=\"top\">Ra 3.2-6.3 \u03bcm<\/td>\n<td valign=\"top\" width=\"239\">Contact Profilometer<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"187\">Bolt Preload Force<\/td>\n<td valign=\"top\">\u00b15% of Design Value<\/td>\n<td valign=\"top\" width=\"239\">Hydraulic Torque Wrench<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"187\">Thermal Cycles<\/td>\n<td valign=\"top\">5 cycles (-30\u00b0C to 100\u00b0C)<\/td>\n<td valign=\"top\" width=\"239\">Environmental Test Chamber<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"padding-left: 40px;\">According to the IEC 60544-2 standard, the sealing system must pass a minimum of 1,000 hours of hot oil aging testing (110\u00b0C), with performance degradation not exceeding 20% of the initial value.<\/p>\n<h3><em>2. Technological Breakthroughs in Dry-Type Transformer Lead Sealing<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><strong>2.1 Molecular-Level Sealing with Epoxy Resin Casting<\/strong><i><\/i><\/h4>\n<h5 style=\"padding-left: 80px;\"><strong>2.1.1 Modern dry-type transformers use nano-modified epoxy resin systems, with the curing process following the Kamal kinetic model:<\/strong><\/h5>\n<p style=\"padding-left: 40px; text-align: center;\"><b>d\u03b1\/dt = (k1 + k2\u03b1^m)(1-\u03b1)^n<\/b><\/p>\n<p style=\"padding-left: 80px;\">O\u00f9:<\/p>\n<p style=\"padding-left: 80px;\">\u03b1: Degree of curing (0-1)<\/p>\n<p style=\"padding-left: 80px;\">k1, k2: Reaction rate constants<\/p>\n<p style=\"padding-left: 80px;\">m, n: Reaction orders<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.1.2 Nuclear magnetic resonance (NMR) monitoring reveals the optimal curing process:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>(1)Stepwise Heating:\u00a050\u00b0C (2h) \u2192 80\u00b0C (4h) \u2192 110\u00b0C (6h)<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>(2)Vacuum Control:\u00a0\u226450 Pa<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>(3)Curing Agent Ratio:EP862 Resin : Methyltetrahydrophthalic Anhydride = 100:85 (by weight)<\/strong><\/h6>\n<p style=\"padding-left: 40px;\">This process ensures a resin volume shrinkage rate below 0.3%, preventing cracks caused by internal stress.<\/p>\n<h4 style=\"padding-left: 40px;\"><strong>2.2 Interface Engineering with Silicone Rubber Sealing<\/strong><i><\/i><\/h4>\n<p style=\"padding-left: 40px;\">Low-voltage leads in dry-type transformers use specially formulated silicone rubber sealing, with key technologies including:<\/p>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Surface Treatment:Plasma activation (300W, 90s) increases copper conductor surface energy to 72 mN\/m.<\/strong><\/h6>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Adhesive System:\u03b3-Aminopropyltriethoxysilane (KH-550) is used as a coupling agent at 1.5 wt% of the silicone rubber.<\/strong><\/h6>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Elastic Modulus:Reinforced with silica to achieve a final product modulus of 3-5 MPa.<\/strong><\/h6>\n<p style=\"padding-left: 40px;\">Test data show that this sealing system retains over 85% of its initial interfacial bond strength after 1,000 hours in an 85\u00b0C\/85% RH environment.<\/p>\n<h3><em>3. Technical Comparison and Engineering Selection Guide<\/em><b><\/b><\/h3>\n<h6 style=\"padding-left: 40px;\"><strong>(1) Quantitative Comparison of Sealing Performance<\/strong><i><\/i><\/h6>\n<table width=\"676\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"177\"><b>Performance Metric<\/b><\/td>\n<td valign=\"top\" width=\"188\"><b>Oil-Immersed Transformer<\/b><\/td>\n<td valign=\"top\" width=\"157\"><b>Dry-Type Transformer<\/b><\/td>\n<td valign=\"top\" width=\"154\"><b>Testing Standard<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"177\">Leakage Rate<\/td>\n<td valign=\"top\" width=\"188\">&lt;5\u00d710\u207b\u2076 Pa\u00b7m\u00b3\/s<\/td>\n<td valign=\"top\" width=\"157\">N\/A<\/td>\n<td valign=\"top\" width=\"154\">ISO 15848<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"177\">Moisture Permeability<\/td>\n<td valign=\"top\" width=\"188\">&lt;0.1 g\/m\u00b2\u00b7day<\/td>\n<td valign=\"top\" width=\"157\">&lt;0.01 g\/m\u00b2\u00b7day<\/td>\n<td valign=\"top\" width=\"154\">ASTM E96<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"177\">Temperature Range<\/td>\n<td valign=\"top\" width=\"188\">-40\u00b0C to 120\u00b0C<\/td>\n<td valign=\"top\" width=\"157\">-50\u00b0C to 180\u00b0C<\/td>\n<td valign=\"top\" width=\"154\">IEC 60068<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"177\">UV Resistance<\/td>\n<td valign=\"top\" width=\"188\">Pauvres<\/td>\n<td valign=\"top\" width=\"157\">Excellent (Grade 5)<\/td>\n<td valign=\"top\" width=\"154\">ASTM G154<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h6 style=\"padding-left: 40px;\"><strong>(2) Decision Model for Engineering Selection<\/strong><i><\/i><\/h6>\n<p style=\"padding-left: 40px;\">A weighted scoring method is recommended:<\/p>\n<p style=\"text-align: center;\"><b>Total Score = 0.3\u00d7Weather Resistance + 0.25\u00d7Maintainability + 0.2\u00d7Cost + 0.15\u00d7Safety + 0.1\u00d7Environmental Impact<\/b><\/p>\n<p style=\"padding-left: 40px;\">O\u00f9:<\/p>\n<p style=\"padding-left: 40px;\">Oil-immersed transformers score higher in maintainability and cost.<\/p>\n<p style=\"padding-left: 40px;\">Dry-type transformers excel in weather resistance, safety, and environmental impact.<\/p>\n<p>According to IEEE C57.12.00, dry-type transformers should be prioritized for:underground substations in\u00a0\u00a0high-rise buildings, offshore wind platforms, data centers, and other critical facilities.<\/p>\n<h3><em>4. Cutting-Edge Technologies and Future Trends<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><strong>4.1 Innovative Sealing Technologies for Oil-Immersed Transformers<\/strong><i><\/i><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Self-Healing Sealing Materials:\u00a0Microencapsulated siloxane repair agents (50-100 \u03bcm) automatically release upon crack formation.<\/strong><\/h6>\n<h6 style=\"padding-left: 80px;\"><strong>(2)Smart Monitoring Seals:\u00a0Integrated FBG optical fiber sensors for real-time stress monitoring.<\/strong><\/h6>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Super-Oleophobic Surface Treatment:\u00a0Laser micro-nano processing creates periodic microstructures with contact angles &gt;150\u00b0.<\/strong><\/h6>\n<h4 style=\"padding-left: 40px;\"><strong>4.2 Technological Breakthroughs for Dry-Type Transformers<\/strong><i><\/i><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>(1)Organic-Inorganic Hybrid Materials:SiO\u2082 nanoparticle-modified epoxy resin with thermal conductivity up to 0.45 W\/m\u00b7K.<\/strong><\/h6>\n<h6 style=\"padding-left: 80px;\"><strong>(2)All-Solid Interface Technology:\u00a0Atomic layer deposition (ALD) grows Al\u2082O\u2083 transition layers on conductor surfaces.<\/strong><\/h6>\n<h6 style=\"padding-left: 80px;\"><strong>(3)Digital Twin Monitoring:\u00a0Real-time deformation monitoring using MEMS sensors.<\/strong><\/h6>\n<h2><b><span style=\"font-family: Arial;\">En R\u00e9sum\u00e9<\/span><\/b><b><\/b><\/h2>\n<p>Oil-immersed and dry-type transformers exhibit fundamental differences in lead sealing processes, stemming from their distinct insulating media and working principles. Modern sealing technology has evolved into an interdisciplinary field combining materials science, surface engineering, and smart monitoring. Engineering decisions must consider operational environment, maintenance conditions, and lifecycle costs. With advancements in new materials and processes, transformer sealing technology is moving toward longer lifespans, higher reliability, and intelligent monitoring.<\/p>\n<h2><strong>Contact<\/strong><\/h2>\n<p>LuShan, heure de l'est. 1975, est un fabricant professionnel Chinois sp\u00e9cialis\u00e9 dans les transformateurs de puissance et des r\u00e9acteurs de plus de 50 ans. Les produits de pointe sont <a href=\"https:\/\/www.lstransformer.com\/fr\/\">transformateur monophas\u00e9, triphas\u00e9 transformateurs d'isolement, transformateur \u00e9lectrique, transformateur de distribution, l'\u00e9tape vers le bas et d'intensifier le transformateur de basse tension du transformateur, transformateur \u00e0 haute tension, contr\u00f4le de transformateur toro\u00efdal transformateur, transformateur R-core; inductances DC, AC r\u00e9acteurs, le filtrage du r\u00e9acteur, de ligne et de charge du r\u00e9acteur, des bobines, le filtrage du r\u00e9acteur, et interm\u00e9diaire, \u00e0 haute fr\u00e9quence produits<\/a>.<\/p>\n<p>Nos transformateurs de puissance et les r\u00e9acteurs sont largement utilis\u00e9s dans les 10 domaines d'application: transport en commun rapide, les machines de construction, les \u00e9nergies renouvelables, intelligents de fabrication, des \u00e9quipements m\u00e9dicaux, de la mine de charbon de l'explosion de la pr\u00e9vention, de l'excitation du syst\u00e8me, frittage sous vide(four), d'une climatisation centrale.<\/p>\n<p>En savoir plus sur transformateur de puissance et le r\u00e9acteur: <a href=\"https:\/\/www.lstransformer.com\/fr\/\">www.lstransformer.com<\/a>.<\/p>\n<p>Si vous souhaitez obtenir des solutions personnalis\u00e9es pour les transformateurs ou des r\u00e9acteurs, veuillez nous contacter.<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\nE-mail: marketing@hnlsdz.com<\/p>","protected":false},"excerpt":{"rendered":"<p>Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes Transformers are the core equipment of power systems, and the sealing process of their leads directly impacts the reliability and safety of operation. This article provides an in-depth analysis of the fundamental differences in lead sealing processes between oil-immersed and dry-type transformers, [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":4024,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1170","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD<\/title>\n<meta name=\"description\" content=\"Transformers are the core equipment of power systems, and the sealing process of their leads directly impacts the reliability and safety of operation. This article provides an in-depth analysis of the fundamental differences in lead sealing processes between oil-immersed and dry-type transformers, offering a professional interpretation from multiple dimensions, including materials science, structural design, and process standards.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/fr\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"og:description\" content=\"Transformers are the core equipment of power systems, and the sealing process of their leads directly impacts the reliability and safety of operation. This article provides an in-depth analysis of the fundamental differences in lead sealing processes between oil-immersed and dry-type transformers, offering a professional interpretation from multiple dimensions, including materials science, structural design, and process standards.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/fr\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:32:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-23T07:10:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772280712506018.png\" \/>\n\t<meta property=\"og:image:width\" content=\"370\" \/>\n\t<meta property=\"og:image:height\" content=\"276\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes\",\"datePublished\":\"2026-07-22T05:32:59+00:00\",\"dateModified\":\"2026-09-23T07:10:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/\"},\"wordCount\":972,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1772280712506018.png\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/\",\"name\":\"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1772280712506018.png\",\"datePublished\":\"2026-07-22T05:32:59+00:00\",\"dateModified\":\"2026-09-23T07:10:25+00:00\",\"description\":\"Transformers are the core equipment of power systems, and the sealing process of their leads directly impacts the reliability and safety of operation. This article provides an in-depth analysis of the fundamental differences in lead sealing processes between oil-immersed and dry-type transformers, offering a professional interpretation from multiple dimensions, including materials science, structural design, and process standards.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1772280712506018.png\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1772280712506018.png\",\"width\":370,\"height\":276},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"Transformers are the core equipment of power systems, and the sealing process of their leads directly impacts the reliability and safety of operation. This article provides an in-depth analysis of the fundamental differences in lead sealing processes between oil-immersed and dry-type transformers, offering a professional interpretation from multiple dimensions, including materials science, structural design, and process standards.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/fr\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/","og_locale":"fr_FR","og_type":"article","og_title":"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","og_description":"Transformers are the core equipment of power systems, and the sealing process of their leads directly impacts the reliability and safety of operation. This article provides an in-depth analysis of the fundamental differences in lead sealing processes between oil-immersed and dry-type transformers, offering a professional interpretation from multiple dimensions, including materials science, structural design, and process standards.","og_url":"https:\/\/www.lstransformer.com\/fr\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:32:59+00:00","article_modified_time":"2026-09-23T07:10:25+00:00","og_image":[{"width":370,"height":276,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772280712506018.png","type":"image\/png"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"369703005","Dur\u00e9e de lecture estim\u00e9e":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes","datePublished":"2026-07-22T05:32:59+00:00","dateModified":"2026-09-23T07:10:25+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/"},"wordCount":972,"commentCount":0,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772280712506018.png","articleSection":["FAQ"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/","url":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/","name":"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772280712506018.png","datePublished":"2026-07-22T05:32:59+00:00","dateModified":"2026-09-23T07:10:25+00:00","description":"Transformers are the core equipment of power systems, and the sealing process of their leads directly impacts the reliability and safety of operation. This article provides an in-depth analysis of the fundamental differences in lead sealing processes between oil-immersed and dry-type transformers, offering a professional interpretation from multiple dimensions, including materials science, structural design, and process standards.","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772280712506018.png","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1772280712506018.png","width":370,"height":276},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/oil-immersed-transformers-vs-dry-type-transformers-a-deep-technical-analysis-of-lead-sealing-processes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"Oil-Immersed Transformers vs. Dry-Type Transformers: A Deep Technical Analysis of Lead Sealing Processes"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS transformateur de puissance, r\u00e9acteur de Ligne \u00e0 Haute tension transformateur d'Huile de transformateur immerg\u00e9-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS transformateur de puissance, r\u00e9acteur de Ligne \u00e0 Haute tension transformateur d'Huile de transformateur immerg\u00e9-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/fr\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts\/1170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/comments?post=1170"}],"version-history":[{"count":5,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts\/1170\/revisions"}],"predecessor-version":[{"id":6252,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts\/1170\/revisions\/6252"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/media\/4024"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/media?parent=1170"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/categories?post=1170"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/tags?post=1170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}