{"id":1502,"date":"2026-07-22T05:33:27","date_gmt":"2026-07-22T05:33:27","guid":{"rendered":"https:\/\/lstransformer.com\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/"},"modified":"2026-09-30T02:07:40","modified_gmt":"2026-09-30T02:07:40","slug":"what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/","title":{"rendered":"What is the purpose of measuring the no-load voltage and no-load current?"},"content":{"rendered":"<h1 style=\"text-align: left;\">What is the purpose of measuring the no-load voltage and no-load current?<b><\/b><\/h1>\n<p>Measuring the no-load voltage and no-load current is a critical aspect of assessing transformer performance and quality. These measurements can reveal the operational status and characteristics of the transformer under no-load conditions, providing essential data support for design, manufacturing, and maintenance. The primary objectives of measuring no-load voltage and no-load current are as follows:<\/p>\n<h2><b>Contenu<\/b><\/h2>\n<h3><em>1. Verification of Transformer Design Parameters:<\/em><b><\/b><\/h3>\n<p>When the no-load losses of a transformer are minimal, the no-load voltage is essentially equal to the induced voltage, and the ratio of the primary to secondary no-load voltages is equal to the turns ratio. By measuring the no-load voltage, it is possible to verify whether the turns ratio of the\u00a0transformer design meets the design specifications, ensuring that the transformer provides an accurate voltage transformation ratio under rated conditions.<\/p>\n<h3><em>2. Assessment of Coil Quality and Turns:<\/em><b><\/b><\/h3>\n<p>The no-load voltage is closely related to the number of turns in the transformer\u2019s coils. By measuring the no-load voltage, one can check whether the number of turns in the coils is correct and whether the winding process meets the required standards. This helps assess the manufacturing quality and consistency of the coils.<\/p>\n<p><a title=\"Transformateur, de Gros Transformateurs de Fournitures et de Fabricants,Sp\u00e9cialis\u00e9e dans les Transformateurs de 49 ans\" href=\"https:\/\/www.lstransformer.com\/fr\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter\" title=\"69\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1742198862743522.jpg\" alt=\"undefined\" width=\"410\" height=\"393\" border=\"0\" vspace=\"0\" \/><\/a><\/p>\n<h3><em>3. Evaluation of Core Electromagnetic Performance:<\/em><b><\/b><\/h3>\n<p>The no-load current is the vector sum of the core loss current and the magnetizing current, and its magnitude depends on the core\u2019s electromagnetic performance. By measuring the no-load current, one can assess the magnetic permeability, hysteresis losses, and eddy current losses of the core material, thereby determining whether the core material and processing meet the required standards.<\/p>\n<h3><em>4. Inspection of Assembly Quality:<\/em><b><\/b><\/h3>\n<p>The no-load current is also influenced by factors such as the number of turns in the transformer coils, short-circuit conditions, and non-magnetic gaps in the magnetic circuit during the assembly process. Measuring the no-load current can help identify issues in the assembly process, such as coil short-circuits or non-magnetic gaps in the magnetic circuit, ensuring the quality of the assembly and the operational performance of the transformer.<\/p>\n<h3><em>5. Assessment of Core and Coil Losses:<\/em><b><\/b><\/h3>\n<p>By measuring the no-load current, one can calculate the core loss current and the magnetizing current, thereby assessing the core losses and the magnetizing performance of the transformer coils. This is crucial for optimizing transformer design and improving energy efficiency.<\/p>\n<p><a title=\"Transformateur, de Gros Transformateurs de Fournitures et de Fabricants,Sp\u00e9cialis\u00e9e dans les Transformateurs de 49 ans\" href=\"https:\/\/www.lstransformer.com\/fr\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter\" title=\"70\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1742198872266017.jpg\" alt=\"undefined\" width=\"410\" height=\"393\" border=\"0\" vspace=\"0\" \/><\/a><\/p>\n<h3><em>6. Evaluation of Overall Transformer Performance:<\/em><b><\/b><\/h3>\n<p>The results of measuring the no-load voltage and no-load current provide a comprehensive reflection of the quality of the transformer\u2019s coils, core, and assembly process. These measurements allow for a thorough evaluation of the transformer\u2019s overall performance, ensuring that it operates in a good working condition and reliability during actual operation.<\/p>\n<h3><em>7. Provision of Benchmark Data for Subsequent Testing and Maintenance:<\/em><b><\/b><\/h3>\n<p>The results of no-load voltage and no-load current measurements can serve as benchmark data for subsequent testing and maintenance. During the operation and maintenance of the transformer, regular measurement of no-load characteristics can be compared with benchmark data to identify and address potential issues in a timely manner, ensuring the long-term safe and reliable operation of the transformer.<\/p>\n<h2><b>En r\u00e9sum\u00e9<\/b><\/h2>\n<p>By measuring the no-load voltage and no-load current, one can gain a comprehensive understanding of the transformer\u2019s design and manufacturing quality, assess its electromagnetic performance and operational status, and provide a scientific basis for optimizing design, improving manufacturing processes, ensuring assembly quality, and performing effective maintenance. Accurate no-load characteristic measurements are crucial for ensuring transformer performance and reliability, contributing to the overall quality and operational efficiency of the transformer.<\/p>\n<p><a title=\"Transformateur, de Gros Transformateurs de Fournitures et de Fabricants,Sp\u00e9cialis\u00e9e dans les Transformateurs de 49 ans\" href=\"https:\/\/www.lstransformer.com\/fr\/Transformers\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter\" title=\"71\" src=\"https:\/\/manage.lstransformer.com\/upload\/news\/1742198883432358.jpg\" alt=\"undefined\" width=\"410\" height=\"393\" border=\"0\" vspace=\"0\" \/><\/a><\/p>\n<h4><\/h4>\n<h2 style=\"font-weight: bold;\">Contact<\/h2>\n<p>LuShan, heure de l'est. 1975, est un fabricant professionnel Chinois sp\u00e9cialis\u00e9 dans les transformateurs de puissance et des r\u00e9acteurs de plus de 50 ans. Les produits de pointe sont <a href=\"https:\/\/www.lstransformer.com\/fr\/\">transformateur monophas\u00e9, triphas\u00e9 transformateurs d'isolement, transformateur \u00e9lectrique, transformateur de distribution, l'\u00e9tape vers le bas et d'intensifier le transformateur de basse tension du transformateur, transformateur \u00e0 haute tension, contr\u00f4le de transformateur toro\u00efdal transformateur, transformateur R-core; inductances DC, AC r\u00e9acteurs, le filtrage du r\u00e9acteur, de ligne et de charge du r\u00e9acteur, des bobines, le filtrage du r\u00e9acteur, et interm\u00e9diaire, \u00e0 haute fr\u00e9quence produits<\/a>.<\/p>\n<p>Nos transformateurs de puissance et les r\u00e9acteurs sont largement utilis\u00e9s dans les 10 domaines d'application: transport en commun rapide, les machines de construction, les \u00e9nergies renouvelables, intelligents de fabrication, des \u00e9quipements m\u00e9dicaux, de la mine de charbon de l'explosion de la pr\u00e9vention, de l'excitation du syst\u00e8me, frittage sous vide(four), d'une climatisation centrale.<\/p>\n<p>En savoir plus sur transformateur de puissance et le r\u00e9acteur: <a href=\"https:\/\/www.lstransformer.com\/fr\/\">www.lstransformer.com<\/a>.<\/p>\n<p>Si vous souhaitez obtenir des solutions personnalis\u00e9es pour les transformateurs ou des r\u00e9acteurs, veuillez nous contacter.<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\nE-mail: marketing@hnlsdz.com<\/p>","protected":false},"excerpt":{"rendered":"<p>What is the purpose of measuring the no-load voltage and no-load current? Measuring the no-load voltage and no-load current is a critical aspect of assessing transformer performance and quality. These measurements can reveal the operational status and characteristics of the transformer under no-load conditions, providing essential data support for design, manufacturing, and maintenance. The primary [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2122,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1502","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What is the purpose of measuring the no-load voltage and no-load current? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD<\/title>\n<meta name=\"description\" content=\"Measuring the no-load voltage and no-load current is a critical aspect of assessing transformer performance and quality. These measurements can reveal the operational status and characteristics of the transformer under no-load conditions, providing essential data support for design, manufacturing, and maintenance. The primary objectives of measuring no-load voltage and no-load current are as follows:\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is the purpose of measuring the no-load voltage and no-load current? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"og:description\" content=\"Measuring the no-load voltage and no-load current is a critical aspect of assessing transformer performance and quality. These measurements can reveal the operational status and characteristics of the transformer under no-load conditions, providing essential data support for design, manufacturing, and maintenance. The primary objectives of measuring no-load voltage and no-load current are as follows:\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:33:27+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-30T02:07:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1741937758576725.png\" \/>\n\t<meta property=\"og:image:width\" content=\"370\" \/>\n\t<meta property=\"og:image:height\" content=\"276\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"What is the purpose of measuring the no-load voltage and no-load current?\",\"datePublished\":\"2026-07-22T05:33:27+00:00\",\"dateModified\":\"2026-09-30T02:07:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/\"},\"wordCount\":718,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1741937758576725.png\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/\",\"name\":\"What is the purpose of measuring the no-load voltage and no-load current? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1741937758576725.png\",\"datePublished\":\"2026-07-22T05:33:27+00:00\",\"dateModified\":\"2026-09-30T02:07:40+00:00\",\"description\":\"Measuring the no-load voltage and no-load current is a critical aspect of assessing transformer performance and quality. These measurements can reveal the operational status and characteristics of the transformer under no-load conditions, providing essential data support for design, manufacturing, and maintenance. The primary objectives of measuring no-load voltage and no-load current are as follows:\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1741937758576725.png\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1741937758576725.png\",\"width\":370,\"height\":276},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is the purpose of measuring the no-load voltage and no-load current?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/fr\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is the purpose of measuring the no-load voltage and no-load current? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"Measuring the no-load voltage and no-load current is a critical aspect of assessing transformer performance and quality. These measurements can reveal the operational status and characteristics of the transformer under no-load conditions, providing essential data support for design, manufacturing, and maintenance. The primary objectives of measuring no-load voltage and no-load current are as follows:","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/","og_locale":"fr_FR","og_type":"article","og_title":"What is the purpose of measuring the no-load voltage and no-load current? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","og_description":"Measuring the no-load voltage and no-load current is a critical aspect of assessing transformer performance and quality. These measurements can reveal the operational status and characteristics of the transformer under no-load conditions, providing essential data support for design, manufacturing, and maintenance. The primary objectives of measuring no-load voltage and no-load current are as follows:","og_url":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:33:27+00:00","article_modified_time":"2026-09-30T02:07:40+00:00","og_image":[{"width":370,"height":276,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1741937758576725.png","type":"image\/png"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"369703005","Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"What is the purpose of measuring the no-load voltage and no-load current?","datePublished":"2026-07-22T05:33:27+00:00","dateModified":"2026-09-30T02:07:40+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/"},"wordCount":718,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1741937758576725.png","articleSection":["FAQ"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/","url":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/","name":"What is the purpose of measuring the no-load voltage and no-load current? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1741937758576725.png","datePublished":"2026-07-22T05:33:27+00:00","dateModified":"2026-09-30T02:07:40+00:00","description":"Measuring the no-load voltage and no-load current is a critical aspect of assessing transformer performance and quality. These measurements can reveal the operational status and characteristics of the transformer under no-load conditions, providing essential data support for design, manufacturing, and maintenance. The primary objectives of measuring no-load voltage and no-load current are as follows:","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1741937758576725.png","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1741937758576725.png","width":370,"height":276},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/fr\/what-is-the-purpose-of-measuring-the-no-load-voltage-and-no-load-current\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"What is the purpose of measuring the no-load voltage and no-load current?"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS transformateur de puissance, r\u00e9acteur de Ligne \u00e0 Haute tension transformateur d'Huile de transformateur immerg\u00e9-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS transformateur de puissance, r\u00e9acteur de Ligne \u00e0 Haute tension transformateur d'Huile de transformateur immerg\u00e9-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/fr\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts\/1502","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/comments?post=1502"}],"version-history":[{"count":6,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts\/1502\/revisions"}],"predecessor-version":[{"id":7077,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/posts\/1502\/revisions\/7077"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/media\/2122"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/media?parent=1502"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/categories?post=1502"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/fr\/wp-json\/wp\/v2\/tags?post=1502"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}