{"id":1135,"date":"2026-07-22T05:32:56","date_gmt":"2026-07-22T05:32:56","guid":{"rendered":"https:\/\/lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/"},"modified":"2026-09-30T05:14:08","modified_gmt":"2026-09-30T05:14:08","slug":"how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/ja\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/","title":{"rendered":"\u3069\u306e\u3088\u3046\u306b\u539f\u5b50\u7089\u3092\u907f\u3051\u308b\u51dd\u7e2e\u3001\u6e7f\u6c17\u306e\u591a\u3044\u74b0\u5883\u3092\u4fdd\u8b77\u683c\u4ed8?"},"content":{"rendered":"<p>\u96fb\u529b\u30b7\u30b9\u30c6\u30e0\u3084\u7523\u696d\u7528\u9014\u3067\u306f\u3001\u539f\u5b50\u7089\u306e\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u3067\u7121\u52b9\u96fb\u529b\u88dc\u511f\u304a\u3088\u3073\u96fb\u6d41\u5236\u9650\u3001\u305d\u306e\u4fe1\u983c\u6027\u3068\u5b89\u5b9a\u6027\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002 \u305f\u3060\u3057\u3001\u6e7f\u6c17\u306e\u591a\u304f\u306f\u6c17\u5019\u5909\u52d5\u3001\u51dd\u7e2e\u5f62\u5185\u5074\u7089\u306e\u4f4e\u6e1b\u3001\u7d76\u7e01\u6027\u80fd\u65ad\u71b1\u6027\u80fd\u3084\u53ef\u80fd\u6027\u304c\u77ed\u56de\u8def\u307e\u305f\u306f\u88c5\u7f6e\u3002 \u3053\u306e\u8a18\u4e8b\u306b\u306f\u4f55\u304c\u5fc5\u8981\u304b\u3092\u8003\u5bdf\u6b63\u4fb5\u5165\u4fdd\u8b77(IP)\u306e\u683c\u4ed8\u3051\u306e\u8a2d\u8a08\u3092\u652f\u63f4\u3059\u308b\u63aa\u7f6e\u304c\u52b9\u679c\u7684\u306b\u9632\u6b62\u51dd\u7e2e\u539f\u5b50\u7089\u3067\u306e\u55b6\u696d\u3001\u6e7f\u6c17\u306e\u591a\u3044\u3002 \u3092\u3054\u7d39\u4ecb\u3057\u307e\u56fd\u969b\u7684\u306b\u8a8d\u3081\u3089\u308c\u305f\u4fdd\u8b77\u57fa\u6e96\u306e\u5b9f\u8df5\u7684\u306a\u65b9\u6cd5\u3092\u30e6\u30fc\u30b6\u30fc\u3092\u9078\u629e\u3057\u3001\u7dad\u6301\u306b\u9069\u3057\u305f\u539f\u5b50\u7089\u306e\u88fd\u54c1\u306e\u6e7f\u3063\u305f\u74b0\u5883\u3067\u3059\u3002<\/p>\n<h2 style=\"text-align: left;\"><b><span style=\"font-family: Arial;\">\u30b3\u30f3\u30c6\u30f3\u30c4<\/span><\/b><b><\/b><\/h2>\n<h3><em><img class=\"anchorclass\" \/><b>1. \u7406\u89e3\u306e\u51dd\u7e2e\u53ca\u3073\u305d\u306e\u30ea\u30b9\u30af\u3092\u7089<\/b><\/em><b><\/b><\/h3>\n<p>\u7d50\u9732\u767a\u751f\u6642\u306e\u7a7a\u6c17\u4e2d\u306e\u6c34\u84b8\u6c17\u63a5\u70b9\u306e\u8868\u9762\u304c\u6e29\u5ea6\u3092\u4e0b\u306e\u9732\u70b9\u304b\u3089\u306e\u30ac\u30b9\u3092\u6db2\u4f53\u306e\u6c34\u3067\u3059\u3002 \u306e\u305f\u3081\u306e\u7089\u3067\u306f\u3001\u7d50\u9732\u304c\u4e3b\u306b\u767a\u751f\u3059\u308b\u4e8c\u3064\u306e\u72b6\u6cc1:<\/p>\n<h4 style=\"padding-left: 40px;\"><b>1.1 <\/b><b>\u7d50\u9732\u306b\u3088\u308a\u663c\u591c\u306e\u6e29\u5ea6\u5dee\u6e29\u5ea6\u5909\u52d5<\/b><b><\/b><\/h4>\n<p style=\"padding-left: 40px;\">\u5730\u57df\u306b\u304a\u3051\u308b\u5927\u65e5\u5909\u52d5\u5e45\u304c\u5c0f\u3055\u304f\u3001\u591c\u9593\u51b7\u5374\u306e\u539f\u56e0\u3068\u306a\u308a\u3001\u5185\u90e8\u306e\u8868\u9762\u6e29\u5ea6\u306e\u539f\u5b50\u7089\u306e\u7b50\u4f53\u306b\u3088\u308a\u4e0b\u306f\u907f\u3051\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<h4 style=\"padding-left: 40px;\"><b>1.2 <\/b><b>\u7d50\u9732\u5f8c\u306e\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u3068\u518d\u8d77\u52d5:<\/b><b><\/b><\/h4>\n<p style=\"padding-left: 40px;\">\u6642\u306e\u539f\u5b50\u7089\u3067\u306e\u518d\u6e7f\u306e\u74b0\u5883\u3001\u5dfb\u7dda\u306e\u6e29\u5ea6\u4e0a\u6607\u306e\u5897\u52a0\u5185\u7a7a\u6c17\u306e\u6c34\u5206\u51b7\u5374\u3059\u308b\u3068\u3001\u3053\u306e\u6c34\u5206\u304c\u51dd\u7e2e\u306b\u30af\u30fc\u30e9\u30fc\u3002<\/p>\n<p style=\"padding-left: 40px;\"><b>\u30ad\u30ea\u30b9\u30af\u51dd\u7e2e\u306e\u305f\u3081\u306e\u539f\u5b50\u7089\u3092\u542b\u3080:<\/b><b><\/b><\/p>\n<h4 style=\"padding-left: 40px;\"><b>1.3 <\/b><b>\u6e1b\u65ad\u71b1\u6027\u80fd:<\/b><b><\/b><\/h4>\n<p style=\"padding-left: 40px;\">\u6c34\u5206\u306e\u4f4e\u8868\u9762\u62b5\u6297\u7387\u56fa\u4f53\u7d76\u7e01\u6750\u6599\u3067\u3059\u3002<\/p>\n<h4 style=\"padding-left: 40px;\"><b>1.4<\/b><b>\u306e\u5897\u52a0\u90e8\u5206\u653e\u96fb:<\/b><b><\/b><\/h4>\n<p style=\"padding-left: 40px;\">\u6c34\u3068\u6c5a\u67d3\u7269\u8cea\u3092\u5f62\u6210\u3067\u304d\u308b\u5c0e\u96fb\u6027\u306e\u30d1\u30b9\u3092\u3001\u90e8\u5206\u653e\u96fb\u306f\u3001\u5f90\u3005\u306b\u8755\u3080\u7d76\u7e01\u88ab\u8986\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<h4 style=\"padding-left: 40px;\"><b>1.5<\/b><b>\u8010\u98df\u91d1\u5c5e\u30d1\u30fc\u30c4\uff1a<\/b><b><\/b><\/h4>\n<p style=\"padding-left: 40px;\">\u9577\u671f\u66b4\u9732\u306b\u51dd\u7d50\u52a0\u901f\u9178\u5316\u3084\u8150\u98df\u306a\u3069\u306e\u9285\u5dfb\u7dda\u306e\u9244\u30b3\u30a2\u3092\u77ed\u7e2e\u88c5\u7f6e\u306e\u9577\u5bff\u547d\u5316\u3092\u3082\u305f\u3089\u3057\u307e\u3057\u305f\u3002<\/p>\n<table width=\"735\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\"><b>\u5468\u56f2\u76f8\u5bfe\u6e7f\u5ea6<\/b><\/td>\n<td valign=\"top\"><b>\u4ee3\u8868\u7684\u306a\u7d76\u7e01\u62b5\u6297(M\u03a9)<\/b><\/td>\n<td valign=\"top\"><b>\u65ad\u71b1\u6027\u80fd\u306e\u8a55\u4fa1<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">&lt;60%<\/td>\n<td valign=\"top\">&gt;1000<\/td>\n<td valign=\"top\">\u512a\u308c\u305f<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">60%-75%<\/td>\n<td valign=\"top\">500-1000<\/td>\n<td valign=\"top\">\u826f\u3044<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">75%-85%<\/td>\n<td valign=\"top\">100-500<\/td>\n<td valign=\"top\">\u30d5\u30a7\u30a2<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">&gt;85%<\/td>\n<td valign=\"top\">&lt;100<\/td>\n<td valign=\"top\">\u8ca7\u3057\u3044\u9ad8\u30ea\u30b9\u30af<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"table-note\" style=\"text-align: center;\">\u88681:\u5909\u52d5\u306e\u4ee3\u8868\u7684\u306a\u7d76\u7e01\u62b5\u6297\u539f\u5b50\u7089\u3068\u7570\u306a\u308b\u6e7f\u5ea6<\/div>\n<h3><em><img class=\"anchorclass\" \/><b>2. IP\u683c\u4ed8\u3051\u306e\u539f\u5247\u304a\u3088\u3073\u305d\u306e\u7d50\u9732\u9632\u6b62<\/b><\/em><b><\/b><\/h3>\n<p>IP\u683c\u4ed8\u3051\u306f\u6a19\u6e96\u5316\u3055\u308c\u305f\u5206\u985e\u30b7\u30b9\u30c6\u30e0\u306e\u958b\u767a\u306b\u3088\u308a\u3001\u56fd\u969b\u96fb\u6c17\u6a19\u6e96\u4f1a\u8b70(IEC60529)\u3092\u5b9a\u7fa9\u3059\u308b\u4fdd\u8b77\u6c34\u6e96\u306e\u96fb\u6c17\u6a5f\u5668\u306e\u7b50\u4f53\u306b\u5bfe\u3057\u56fa\u4f53\u304a\u3088\u3073\u6db2\u4f53\u3067\u3059\u3002 \u5e45\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u306e\u4fdd\u8b77\u8a2d\u8a08\u306e\u96fb\u6e90\u88c5\u7f6e\u306e\u3088\u3046\u306a\u30c8\u30e9\u30f3\u30b9\u3001\u3067\u3042\u308b\u3002<\/p>\n<h4 style=\"padding-left: 40px;\"><strong><img class=\"anchorclass\" \/>2.1\u00a0Understanding the IP Code<\/strong><\/h4>\n<h5 style=\"padding-left: 80px;\"><strong>2.1.1An IP code consists of two digits:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09First digit: Protection against solid objects (0\u20136)<\/strong><br \/>\n<strong>\uff082\uff09Second digit: Protection against liquids, primarily water (0\u20139K)<i><\/i><\/strong><\/h6>\n<h5 style=\"padding-left: 80px;\"><strong>2.1.2For reactors in humid environments, the second digit is particularly important. Common moisture-related protection levels include:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09IPX3:Protected against spraying water at up to up to 60\u00b0 from vertical.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09IPX4:Protected against splashing water from any direction.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09IPX5:Protected against water jets from any direction.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff084\uff09IPX7:Protected against temporary immersion in water.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff085\uff09IPX8:Protected against continuous immersion under specified conditions.<\/strong><\/h6>\n<h4 style=\"padding-left: 40px;\"><strong><img class=\"anchorclass\" \/>2.2\u00a0Anti-Condensation Design Features of High IP-Rated Reactors<\/strong><b><\/b><\/h4>\n<p style=\"padding-left: 40px;\">\u9054\u6210IP56\u4ee5\u4e0a\u306e\u9ad8\u7089\u4e00\u822c\u7684\u306b\u53d6\u308a\u8fbc\u3080:<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>2.2.1Sealed Structure Design:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>(1) One-piece molded or welded sealed enclosures to minimize seams and openings.<\/strong><br \/>\n<strong>(2) Silicone or fluor rubber gaskets with compression set &lt;15%.<\/strong><br \/>\n<strong>(3) Double-sealed terminals: inner epoxy potting, outer elastomer seal.<\/strong><\/h6>\n<h5 style=\"padding-left: 80px;\"><strong>2.2.2Breathing System Design:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>(1) Polymer membrane breathers (e.g., ePTFE) with micropores (0.2\u20130.5\u00b5m), allowing air passage but blocking liquid water.<\/strong><br \/>\n<strong>(2) Built-in silica gel desiccant with moisture absorption capacity\u226530%.<\/strong><br \/>\n<strong>(3) Integrated dust filter layer with efficiency\u226599% for particles\u22655\u00b5m.<\/strong><\/h6>\n<h5 style=\"padding-left: 80px;\"><strong>2.2.3Internal Humidity Control:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>(1) Built-in heaters that activate when ambient humidity &gt;70%, maintaining internal temperature 3\u20135\u00b0C above dew point.<\/strong><br \/>\n<strong>(2) Humidity indicator cards or electronic sensors for visual management.<\/strong><br \/>\n<strong>(3) Moisture-resistant insulation materials like Nomex\u00ae paper, with absorption rate &lt;3%.<\/strong><i><\/i><\/h6>\n<table width=\"668\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\"><b>IP\u683c\u4ed8\u3051<\/b><b><\/b><\/td>\n<td valign=\"top\"><b>\u4fdd\u8b77\u6a5f\u80fd<\/b><b><\/b><\/td>\n<td valign=\"top\"><b>\u9069\u5207\u306a\u74b0\u5883<\/b><b><\/b><\/td>\n<td valign=\"top\"><b>\u6297\u51dd\u7e2e\u52b9\u679c<\/b><b><\/b><\/td>\n<td valign=\"top\"><b>\u4ee3\u8868\u7684\u306a\u7528\u9014<\/b><b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">IP44<\/td>\n<td valign=\"top\">\u30b9\u30d7\u30e9\u30c3\u30b7\u30e5\u9632\u6c34<\/td>\n<td valign=\"top\">\u8efd\u304f\u84b8\u3057\u6691\u3044\u306e\u3067\u3001\u5165\u308a\u6c5f\u5c4b<\/td>\n<td valign=\"top\">\u30d5\u30a7\u30a2<\/td>\n<td valign=\"top\">\u5de5\u5834\u5185<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">IP55<\/td>\n<td valign=\"top\">\u4f4e\u5727\u6c34\u30b8\u30a7\u30c3\u30c8\u4fdd\u8b77<\/td>\n<td valign=\"top\">\u7de9\u3084\u304b\u306a\u591a\u6e7f\u3067\u3001\u76f4\u63a5\u964d\u96e8<\/td>\n<td valign=\"top\">\u826f\u3044<\/td>\n<td valign=\"top\">\u534a\u5c4b\u5916\u30b9\u30a4\u30c3\u30c1\u306e\u5ba2\u5ba4<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">IP65<\/td>\n<td valign=\"top\">\u7c89\u5875\u91cf\u3092\u8abf\u6574\u51fa\u6765\u307e\u3059\u3002\u4f4e\u5727\u30b8\u30a7\u30c3\u30c8\u4fdd\u8b77<\/td>\n<td valign=\"top\">\u6e7f\u6c17\u3001\u307b\u3053\u308a\u306e\u591a\u3044<\/td>\n<td valign=\"top\">\u3088\u308a\u826f\u3044<\/td>\n<td valign=\"top\">\u6cbf\u5cb8\u90e8\u3001\u9271\u5c71<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">IP66<\/td>\n<td valign=\"top\">\u30c0\u30b9\u30c8\u306b\u53b3\u3057\u304f\u3001\u5f37\u529b\u306a\u30b8\u30a7\u30c3\u30c8\u4fdd\u8b77<\/td>\n<td valign=\"top\">\u53b3\u3057\u3044\u6e7f\u5ea6\u3001\u5869\u6c34\u5674\u9727<\/td>\n<td valign=\"top\">\u512a\u308c\u305f<\/td>\n<td valign=\"top\">\u6d77\u6d0b\u30d7\u30e9\u30c3\u30c8\u30db\u30fc\u30e0\u306b\u306f\u3001\u4ee5\u4e0b\u306e\u30dd\u30fc\u30c8<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">IP67<\/td>\n<td valign=\"top\">\u7c89\u5875\u91cf\u3092\u8abf\u6574\u51fa\u6765\u307e\u3059\u3002\u4eee\u6d78\u6f2c\u8a3c<\/td>\n<td valign=\"top\">\u6975\u7aef\u306b\u6e7f\u5ea6\u3001\u6f5c\u5728\u7684\u6d2a\u6c34<\/td>\n<td valign=\"top\">\u512a\u308c\u305f<\/td>\n<td valign=\"top\">\u5730\u4e0b\u3001\u6d2a\u6c34\u591a\u767a\u5730\u57df<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"table-note\" style=\"text-align: center;\">\u88682\u306b\u9069\u5408\u6bd4\u306e\u7570\u306a\u308bIP\u683c\u4ed8\u7089\u3001\u6e7f\u6c17\u306e\u591a\u3044\u74b0\u5883<\/div>\n<h3><em><img class=\"anchorclass\" \/><b>3. \u88dc\u52a9\u6297\u51dd\u7e2e\u6280\u8853\u3068IP\u683c\u4ed8<\/b><\/em><b><\/b><\/h3>\n<p>\u3057\u304b\u3057\u3001IP\u683c\u4ed8\u3051\u3092\u52b9\u679c\u7684\u306b\u9632\u6b62\u306b\u76f4\u63a5\u6c34\u304c\u6d78\u5165\u3001\u8ffd\u52a0\u306e\u6280\u8853\u304c\u5fc5\u8981\u3068\u5b8c\u5168\u306b\u907f\u3051\u308b\u7e2e\u5408\u74b0\u5883\u306e\u6fc0\u306b\u6e29\u5ea6\u3084\u6e7f\u5ea6\u306e\u5909\u52d5<\/p>\n<h4 style=\"padding-left: 40px;\"><strong><img class=\"anchorclass\" \/>3.1\u00a0Internal Heating System Design<\/strong><b><\/b><\/h4>\n<p style=\"padding-left: 40px;\">\u52a0\u71b1\u30b7\u30b9\u30c6\u30e0\u306e\u9632\u6b62\u306e\u305f\u7d50\u9732\u9632\u6b62\u306e\u305f\u7d50\u9732\u306e\u5185\u90e8\u6e29\u5ea6\u3092\u4e00\u8cab\u3057\u3066\u4e0a\u8a18\u306e\u5468\u56f2\u907f\u3051\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<h5 style=\"padding-left: 80px;\"><b>3.1.1Power Calculation:<\/b><\/h5>\n<p style=\"padding-left: 120px;\">\u52a0\u71b1\u96fb\u529bP\u3054\u6e80\u8db3\u9802\u3051\u308b\u306f\u305a\u3067\u3059:<\/p>\n<p style=\"padding-left: 120px; text-align: center;\"><b><span style=\"font-family: Cambria Math;\">P<\/span><span style=\"font-family: \u5b8b\u4f53;\">\u2265<\/span><span style=\"font-family: Cambria Math;\">k<\/span><span style=\"font-family: \u5b8b\u4f53;\">\u00d7<\/span><span style=\"font-family: Cambria Math;\">A<\/span><span style=\"font-family: \u5b8b\u4f53;\">\u00d7\u0394<\/span><span style=\"font-family: Cambria Math;\">T<\/span><\/b><b><br \/>\n<\/b><i>\u5834\u6240\uff1a<\/i><i><\/i><\/p>\n<p style=\"padding-left: 120px;\"><i>k:\u7dcf\u5408\u71b1\u640d\u5931\u4fc2\u6570(W\/m2-K)\u306f3-5.<\/i><i><\/i><\/p>\n<p style=\"padding-left: 120px;\"><i>A\uff1a\u539f\u5b50\u7089\u306e\u90ed\u8868\u9762\u7a4d(m2)<\/i><i><\/i><\/p>\n<p style=\"padding-left: 120px;\"><i>\u0394T\uff1a\u5fc5\u8981\u306a\u6e29\u5ea6\u5dee(K)\u306f\u3001\u901a\u5e383\u20135K.<\/i><\/p>\n<h5 style=\"padding-left: 80px;\"><strong>3.1.2Control Strategy:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09PID control algorithms adjust heating power based on internal sensor feedback.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Activation threshold:Starts when internal RH &gt;60% or temperature approaches dew point.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Graded power output:Auto-switching between 50%\/75%\/100%.<\/strong><\/h6>\n<h4 style=\"padding-left: 40px;\"><strong><img class=\"anchorclass\" \/>3.2\u00a0Special Coating Technology<\/strong><b><\/b><\/h4>\n<p style=\"padding-left: 80px;\">\u7528\u6297\u51dd\u7e2e\u819c\u5185\u90e8\u306b\u539f\u5b50\u7089\u3092\u63d0\u4f9b\u5225\u4fdd\u8b77\u3057\u307e\u3059\u3002<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>3.2.1Hydrophobic Coatings:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09Main components: Fluorosilicone resin or nano-silica.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Contact angle &gt;110\u00b0, preventing water droplet adherence.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Surface energy &lt;25 mN\/m, reducing moisture adsorption.<i><\/i><\/strong><\/h6>\n<h5 style=\"padding-left: 80px;\"><strong>3.2.2Insulating Moisture-Resistant Varnish:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09Forms a dense film after curing, water vapor transmission rate &lt;5g\/m\u00b2\u00b7day.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Volume resistivity &gt;1\u00d710\u00b9\u2074 \u03a9\u00b7cm.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Temperature class usually F (155\u00b0C) or H (180\u00b0C).<\/strong><\/h6>\n<h4 style=\"padding-left: 40px;\"><strong><img class=\"anchorclass\" \/>3.3\u00a0Ventilation and Humidity Balance Design<\/strong><b><\/b><\/h4>\n<p style=\"padding-left: 80px;\">\u9069\u5207\u306a\u63db\u6c17\u8a2d\u8a08\u306e\u5927\u578b\u7089\u306e\u9632\u6b62\u5c40\u6240\u51dd\u7e2e\u3059\u308b\u3053\u3068<\/p>\n<h5 style=\"padding-left: 80px;\"><strong>3.3.1Air Duct Design Principles:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09&#8221;Bottom-in, top-out&#8221; vertical ducts utilize natural hot air rising.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Airspeed controlled between 0.5\u20131.5 m\/s to avoid rapid cooling.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Duct cross-sectional area S\u2265Q\/(v\u00d73600), where Q is total heat dissipation (W), v is design airspeed (m\/s).<i><\/i><\/strong><\/h6>\n<h5 style=\"padding-left: 80px;\"><strong>3.3.2Humidity Balancing Measures:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09Automatic dampers close when external humidity exceeds internal.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Humidity buffer materials (e.g., silica gel plates, 3\u20135mm thick) at key points.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Labyrinth ventilation structures extend air paths to enhance moisture exchange.<\/strong><i><\/i><\/h6>\n<h3><em><img class=\"anchorclass\" \/><b>4. \u56fd\u969b\u57fa\u6e96\u304a\u3088\u3073\u8a66\u9a13\u65b9\u6cd5<\/b><\/em><b><\/b><\/h3>\n<p>\u3081\u539f\u5b50\u7089\u306e\u4fe1\u983c\u6027\u3092\u9ad8\u6e7f\u5ea6\u74b0\u5883\u3067\u306f\u3001\u4e3b\u8981\u306a\u56fd\u969b\u6a19\u6e96\u5316\u7d44\u7e54\u3092\u8a2d\u3051\u3066\u95a2\u9023\u3059\u308b\u8a66\u9a13\u4ed5\u69d8\u3067\u3059\u3002<\/p>\n<h4 style=\"padding-left: 40px;\"><strong><img class=\"anchorclass\" \/>4.1\u00a0IEC Standard Framework<\/strong><\/h4>\n<h6 style=\"padding-left: 80px;\"><strong>\uff081\uff09IEC 60076-11:Covers loading and temperature rise requirements for dry-type transformers and reactors, including damp heat tests.<\/strong><\/h6>\n<h6 style=\"padding-left: 80px;\"><strong>\uff082\uff09IEC 60721-3-3:Classifies climatic conditions, defining various humidity levels.<\/strong><\/h6>\n<h6 style=\"padding-left: 80px;\"><strong>\uff082\uff09IEC 61373:Vibration and shock tests to verify enclosure integrity under mechanical stress.<\/strong><\/h6>\n<h4 style=\"padding-left: 40px;\"><strong><img class=\"anchorclass\" \/>4.2\u00a0Detailed Test Methods<\/strong><\/h4>\n<h5 style=\"padding-left: 80px;\"><strong>4.2.1Damp Heat Cycle Test (per IEC 60068-2-30):<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09Temperature cycle:25\u00b0C \u2192 40\u00b0C \u2192 25\u00b0C.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Humidity:Maintain 93\u00b13% RH during high-temperature phase.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Cycles:Typically at least 6 full cycles.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff084\uff09Post-test requirements:Insulation resistance \u2265100 M\u03a9, no visible condensation.<\/strong><\/h6>\n<h5 style=\"padding-left: 80px;\"><strong>4.2.2IP Rating Verification Tests:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09IPX5\/X6 Test:Use 12.5mm nozzle, flow rate 100L\/min, distance 3m, duration \u22653 min.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09IPX7 Test:Immersion to 1m depth for 30 minutes.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Post-Test Inspection:No internal water traces; insulation resistance change &lt;10%.<\/strong><\/h6>\n<h3><em><img class=\"anchorclass\" \/>5. \u9078\u629e\u3068\u4fdd\u5b88\u306e\u63d0\u8a00<\/em><b><\/b><\/h3>\n<h4 style=\"padding-left: 40px;\"><img class=\"anchorclass\" \/><strong>5.1\u00a0Selection Guide<\/strong><\/h4>\n<h5 style=\"padding-left: 80px;\"><strong>5.1.1Choose reactors with appropriate IP ratings based on environmental conditions:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09Temperate coastal areas: Recommend IP55 or above, with heating.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Tropical rainforest climate: Recommend IP66, mandatory automatic humidity control.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Areas with large day-night temperature differences: Choose IP54 or above, with internal temperature internal temperature buffering.<\/strong><\/h6>\n<h5 style=\"padding-left: 80px;\"><strong>5.1.2Key Parameter Checklist:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09Maximum relative humidity range.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Annual temperature variation temperature variation amplitude.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Potential water accumulation\/splash risks.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff084\uff09Pollution degree (salt mist, dust, etc.).<\/strong><\/h6>\n<h4 style=\"padding-left: 40px;\"><strong><img class=\"anchorclass\" \/>5.2\u00a0Maintenance Best Practices<\/strong><\/h4>\n<h5 style=\"padding-left: 80px;\"><strong>5.2.1Routine Checks:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09Monthly inspection of seal elasticity (hardness change \u226410 Shore A).<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Quarterly insulation resistance measurement, tracking trends.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Check breather color change; replace if &gt;50% of silica gel has changed color.<\/strong><\/h6>\n<h5 style=\"padding-left: 80px;\"><strong>5.2.2Seasonal Maintenance:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09Test heating system before humid seasons.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Clean ventilation paths, ensuring \u226580% of designed airflow area.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Tighten all external connections per IEC 60076 torque specifications.<\/strong><\/h6>\n<h5 style=\"padding-left: 80px;\"><strong>5.2.3Early Warning Signs:<\/strong><\/h5>\n<h6 style=\"padding-left: 120px;\"><strong>\uff081\uff09Quarterly insulation resistance drop &gt;20%.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff082\uff09Sudden partial discharge increase &gt;30%.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff083\uff09Uneven condensation on enclosure surface.<\/strong><\/h6>\n<h6 style=\"padding-left: 120px;\"><strong>\uff084\uff09Frequent breather saturation (color change cycle &lt;1 month).<\/strong><\/h6>\n<p style=\"padding-left: 40px;\"><a href=\"https:\/\/www.lstransformer.com\/ja\/Reactors\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3412\" src=\"https:\/\/lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280034738611.png\" alt=\"\" width=\"920\" height=\"498\" srcset=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280034738611.png 920w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280034738611-600x325.png 600w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280034738611-300x162.png 300w, https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280034738611-768x416.png 768w\" sizes=\"(max-width: 920px) 100vw, 920px\" \/><\/a><\/p>\n<h2 style=\"text-align: left;\"><b>\u7d50\u8ad6<\/b><b><\/b><\/h2>\n<p>\u4fdd\u8b77\u539f\u5b50\u7089\u304b\u3089\u306e\u51dd\u7e2e\u3001\u6e7f\u6c17\u306e\u591a\u3044\u74b0\u5883\u304c\u5fc5\u8981\u3067\u4f53\u7cfb\u7684\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u7d44\u307f\u5408\u308f\u305b\u9069\u5207\u306aIP\u683c\u4ed8\u306f\u3001\u77e5\u7684\u6e7f\u5ea6\u306e\u7ba1\u7406\u306f\u3001\u53b3\u683c\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3002 \u539f\u5b50\u7089\u5b9a\u683cIP56\u4ee5\u4e0a\u3092\u642d\u8f09\u5185\u90e8\u306e\u71b1\u3092\u52b9\u679c\u7684\u306b\u5bfe\u5fdc\u3058\u307e\u3059\u3002 \u6975\u7aef\u6761\u4ef6IP67\u3068\u7279\u6b8a\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3001\u30d5\u30a3\u30c3\u30b7\u30f3\u30b0\u306b\u512a\u308c\u3092\u4fdd\u8b77\u3057\u307e\u3059\u3002 \u30e6\u30fc\u30b6\u30fc\u3092\u9078\u629e\u53b3\u5bc6\u306b\u8a66\u9a13\u7089\u306b\u57fa\u3065\u304f\u7279\u5b9a\u306e\u74b0\u5883\u30d1\u30e9\u30e1\u30fc\u30bf\u306b\u3064\u3044\u3066\u306f\u3001IEC\u3001IEEE\u6a19\u6e96\u306e\u78ba\u7acb\u3092\u3001\u79d1\u5b66\u7684\u4fdd\u5168\u8a08\u753b\u3092\u9577\u671f\u7684\u306b\u5b89\u5b9a\u3057\u305f\u52d5\u4f5c\u6e7f\u3063\u305f\u3002<\/p>\n<p>\u306e\u9032\u5316\u6750\u6599\u79d1\u5b66\u306e\u958b\u62d3\u3001\u5c06\u6765\u306e\u539f\u5b50\u7089\u306e\u6297\u51dd\u7e2e\u6280\u8853\u3068\u306a\u308b\u30b9\u30de\u30fc\u30c8\u5165AI\u306b\u57fa\u3065\u304f\u6e7f\u5ea6\u4e88\u6e2c\u3068\u81ea\u5df1\u6cbb\u7652\u30eb\u30b7\u30fc\u30eb\u306e\u66f4\u306a\u308b\u6027\u80fd\u5411\u4e0a\u306e\u904e\u9177\u306a\u8a2d\u5b9a\u3057\u307e\u3059\u3002 \u73fe\u5728\u306e\u30cb\u30fc\u30ba\u306b\u3001\u9ad8\u54c1\u8cea\u306e\u88fd\u54c1\u6e96\u62e0\u3057\u305f\u56fd\u969b\u57fa\u6e96\u304a\u3088\u3073\u62c5\u4fdd\u306b\u3088\u308b\u5b8c\u5168\u8a66\u9a13\u30c7\u30fc\u30bf\u304c\u6b8b\u3063\u3066\u6700\u3082\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u907f\u3051\u308b\u51dd\u7e2e\u306e\u30ea\u30b9\u30af\u306b\u5bfe\u3059\u308b<\/p>\n<h2><strong>\u9023\u7d61\u5148<\/strong><\/h2>\n<p>\u5eec\u5c71,est\u3002 1975\u5e74\u306b\u306f\u4e2d\u56fd\u306e\u5c02\u9580\u8077\u306e\u5c02\u9580\u30e1\u30fc\u30ab\u30fc\u306e\u96fb\u529b\u5909\u5727\u5668\u53ca\u3073\u539f\u5b50\u7089\u306e\u305f\u3081\u306e50+\u308b\u3002 \u4e3b\u88fd\u54c1 <a href=\"https:\/\/www.lstransformer.com\/ja\/\">\u5358\u76f8\u30c8\u30e9\u30f3\u30b9\u3001\u4e09\u76f8\u7d76\u7e01\u5909\u5727\u5668\u3001\u96fb\u6c17\u30c8\u30e9\u30f3\u30b9\u3001\u7269\u6d41\u30c8\u30e9\u30f3\u30b9\u3001\u30b9\u30c6\u30c3\u30d7\u306e\u4e0b\u3001\u4fe1\u7528\u30ea\u30b9\u30af\u4ee5\u5916\u306e\u30ea\u30b9\u30af\u306b\u3064\u304d\u30c8\u30e9\u30f3\u30b9\u3001\u4f4e\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u9ad8\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u5236\u5fa1\u30c8\u30e9\u30f3\u30b9\u3001\u30c8\u30ed\u30a4\u30c0\u30eb\u30c8\u30e9\u30f3\u30b9\u3001R\u30b3\u30a2\u30c8\u30e9\u30f3\u30b9\u76f4\u6d41\u30a4\u30f3\u30c0\u30af\u30bf\u30fc\u3001AC\u7089\u3067\u306f\u3001\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u7089\u3001\u8ca0\u8377\u7089chokes\u3001\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u306e\u539f\u5b50\u7089\u306f\u3001\u4e2d\u9593\u4f53\u3001\u9ad8\u5468\u6ce2\u88fd\u54c1<\/a>.<\/p>\n<p>\u5f53\u793e\u306e\u96fb\u529b\u5909\u5727\u5668\u53ca\u3073\u539f\u5b50\u7089\u306b\u5e83\u304f\u4f7f\u7528\u3055\u308c\u306610\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3:\u9ad8\u901f\u9244\u9053\u3001\u5efa\u8a2d\u6a5f\u68b0\u3001\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3001\u30ed\u30dc\u30c3\u30c8\u3001\u533b\u7642\u6a5f\u5668\u3001\u70ad\u9271\u7206\u767a\u306e\u9632\u6b62\u3001\u52b1\u8d77\u30b7\u30b9\u30c6\u30e0\u3001\u771f\u7a7a\u713c\u7d50(\u7089)\u3001\u4e2d\u592e\u30a8\u30a2\u30b3\u30f3\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u77e5\u96fb\u6e90\u30c8\u30e9\u30f3\u30b9\u539f\u5b50\u7089: <a href=\"https:\/\/www.lstransformer.com\/ja\/\">www.lstransformer.com<\/a>.<\/p>\n<p>\u5e0c\u5f97\u306e\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30c8\u30e9\u30f3\u30b9\u3084\u539f\u5b50\u7089\u3001\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\n\u30e1\u30fc\u30eb:marketing@hnlsdz.com<\/p>","protected":false},"excerpt":{"rendered":"<p>In power systems and industrial applications, reactors are crucial for reactive power compensation and current limiting, making their reliability and stability essential. However, in humid or variable climates, condensation can form inside reactors, reducing insulation performance insulation performance and potentially causing short circuits or equipment damage. This article explores how proper Ingress Protection (IP) rating design and supporting measures can effectively prevent condensation in reactors operating in humid conditions. It also introduces internationally recognized protection standards and practical methods to help users select and maintain suitable reactor products for damp environments. Content 1. Understanding Condensation and Its Risks to Reactors Condensation occurs when water vapor in the air contacts a [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":3413,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1135","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How Can Reactors Avoid Condensation in Humid Environments Through Protection Ratings? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD<\/title>\n<meta name=\"description\" content=\"In power systems and industrial applications, reactors are crucial for reactive power compensation and current limiting, making their reliability and stability essential. However, in humid or variable climates, condensation can form inside reactors, reducing insulation performance insulation performance and potentially causing short circuits or equipment damage. This article explores how proper Ingress Protection (IP) rating design and supporting measures can effectively prevent condensation in reactors operating in humid conditions. It also introduces internationally recognized protection standards and practical methods to help users select and maintain suitable reactor products for damp environments.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/ja\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How Can Reactors Avoid Condensation in Humid Environments Through Protection Ratings? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"og:description\" content=\"In power systems and industrial applications, reactors are crucial for reactive power compensation and current limiting, making their reliability and stability essential. However, in humid or variable climates, condensation can form inside reactors, reducing insulation performance insulation performance and potentially causing short circuits or equipment damage. This article explores how proper Ingress Protection (IP) rating design and supporting measures can effectively prevent condensation in reactors operating in humid conditions. It also introduces internationally recognized protection standards and practical methods to help users select and maintain suitable reactor products for damp environments.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/ja\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:32:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-30T05:14:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280552099611.png\" \/>\n\t<meta property=\"og:image:width\" content=\"920\" \/>\n\t<meta property=\"og:image:height\" content=\"498\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"How Can Reactors Avoid Condensation in Humid Environments Through Protection Ratings?\",\"datePublished\":\"2026-07-22T05:32:56+00:00\",\"dateModified\":\"2026-09-30T05:14:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/\"},\"wordCount\":1458,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/17799280552099611.png\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"ja\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/\",\"name\":\"How Can Reactors Avoid Condensation in Humid Environments Through Protection Ratings? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/17799280552099611.png\",\"datePublished\":\"2026-07-22T05:32:56+00:00\",\"dateModified\":\"2026-09-30T05:14:08+00:00\",\"description\":\"In power systems and industrial applications, reactors are crucial for reactive power compensation and current limiting, making their reliability and stability essential. However, in humid or variable climates, condensation can form inside reactors, reducing insulation performance insulation performance and potentially causing short circuits or equipment damage. This article explores how proper Ingress Protection (IP) rating design and supporting measures can effectively prevent condensation in reactors operating in humid conditions. It also introduces internationally recognized protection standards and practical methods to help users select and maintain suitable reactor products for damp environments.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/17799280552099611.png\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/17799280552099611.png\",\"width\":920,\"height\":498},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How Can Reactors Avoid Condensation in Humid Environments Through Protection Ratings?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/ja\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u3069\u306e\u3088\u3046\u306b\u539f\u5b50\u7089\u3092\u907f\u3051\u308b\u51dd\u7e2e\u3001\u6e7f\u6c17\u306e\u591a\u3044\u74b0\u5883\u3092\u4fdd\u8b77\u683c\u4ed8? -LS\u96fb\u6e90\u30c8\u30e9\u30f3\u30b9\u3001\u7089\u3067\u306f\u3001\u9ad8\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u6cb9\u5165\u5909\u5727\u5668-\u9577\u6c99(\u9577\u6c99\u7687\u51a0\u4eee\u65e5\u9152\u5e97)\u5eec\u5c71\u96fb\u5b50\u6280\u8853\u682a\u5f0f\u682a\u5f0f\u4f1a\u793e","description":"\u96fb\u529b\u30b7\u30b9\u30c6\u30e0\u3084\u7523\u696d\u7528\u9014\u3067\u306f\u3001\u539f\u5b50\u7089\u306e\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u3067\u7121\u52b9\u96fb\u529b\u88dc\u511f\u304a\u3088\u3073\u96fb\u6d41\u5236\u9650\u3001\u305d\u306e\u4fe1\u983c\u6027\u3068\u5b89\u5b9a\u6027\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002 \u305f\u3060\u3057\u3001\u6e7f\u6c17\u306e\u591a\u304f\u306f\u6c17\u5019\u5909\u52d5\u3001\u51dd\u7e2e\u5f62\u5185\u5074\u7089\u306e\u4f4e\u6e1b\u3001\u7d76\u7e01\u6027\u80fd\u65ad\u71b1\u6027\u80fd\u3084\u53ef\u80fd\u6027\u304c\u77ed\u56de\u8def\u307e\u305f\u306f\u88c5\u7f6e\u3002 \u3053\u306e\u8a18\u4e8b\u306b\u306f\u4f55\u304c\u5fc5\u8981\u304b\u3092\u8003\u5bdf\u6b63\u4fb5\u5165\u4fdd\u8b77(IP)\u306e\u683c\u4ed8\u3051\u306e\u8a2d\u8a08\u3092\u652f\u63f4\u3059\u308b\u63aa\u7f6e\u304c\u52b9\u679c\u7684\u306b\u9632\u6b62\u51dd\u7e2e\u539f\u5b50\u7089\u3067\u306e\u55b6\u696d\u3001\u6e7f\u6c17\u306e\u591a\u3044\u3002 \u3092\u3054\u7d39\u4ecb\u3057\u307e\u56fd\u969b\u7684\u306b\u8a8d\u3081\u3089\u308c\u305f\u4fdd\u8b77\u57fa\u6e96\u306e\u5b9f\u8df5\u7684\u306a\u65b9\u6cd5\u3092\u30e6\u30fc\u30b6\u30fc\u3092\u9078\u629e\u3057\u3001\u7dad\u6301\u306b\u9069\u3057\u305f\u539f\u5b50\u7089\u306e\u88fd\u54c1\u306e\u6e7f\u3063\u305f\u74b0\u5883\u3067\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/ja\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/","og_locale":"ja_JP","og_type":"article","og_title":"How Can Reactors Avoid Condensation in Humid Environments Through Protection Ratings? - LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","og_description":"In power systems and industrial applications, reactors are crucial for reactive power compensation and current limiting, making their reliability and stability essential. However, in humid or variable climates, condensation can form inside reactors, reducing insulation performance insulation performance and potentially causing short circuits or equipment damage. This article explores how proper Ingress Protection (IP) rating design and supporting measures can effectively prevent condensation in reactors operating in humid conditions. It also introduces internationally recognized protection standards and practical methods to help users select and maintain suitable reactor products for damp environments.","og_url":"https:\/\/www.lstransformer.com\/ja\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:32:56+00:00","article_modified_time":"2026-09-30T05:14:08+00:00","og_image":[{"width":920,"height":498,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280552099611.png","type":"image\/png"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"\u57f7\u7b46\u8005":"369703005","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"12\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"How Can Reactors Avoid Condensation in Humid Environments Through Protection Ratings?","datePublished":"2026-07-22T05:32:56+00:00","dateModified":"2026-09-30T05:14:08+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/"},"wordCount":1458,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280552099611.png","articleSection":["FAQ"],"inLanguage":"ja"},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/","url":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/","name":"\u3069\u306e\u3088\u3046\u306b\u539f\u5b50\u7089\u3092\u907f\u3051\u308b\u51dd\u7e2e\u3001\u6e7f\u6c17\u306e\u591a\u3044\u74b0\u5883\u3092\u4fdd\u8b77\u683c\u4ed8? -LS\u96fb\u6e90\u30c8\u30e9\u30f3\u30b9\u3001\u7089\u3067\u306f\u3001\u9ad8\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u6cb9\u5165\u5909\u5727\u5668-\u9577\u6c99(\u9577\u6c99\u7687\u51a0\u4eee\u65e5\u9152\u5e97)\u5eec\u5c71\u96fb\u5b50\u6280\u8853\u682a\u5f0f\u682a\u5f0f\u4f1a\u793e","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280552099611.png","datePublished":"2026-07-22T05:32:56+00:00","dateModified":"2026-09-30T05:14:08+00:00","description":"\u96fb\u529b\u30b7\u30b9\u30c6\u30e0\u3084\u7523\u696d\u7528\u9014\u3067\u306f\u3001\u539f\u5b50\u7089\u306e\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u3067\u7121\u52b9\u96fb\u529b\u88dc\u511f\u304a\u3088\u3073\u96fb\u6d41\u5236\u9650\u3001\u305d\u306e\u4fe1\u983c\u6027\u3068\u5b89\u5b9a\u6027\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002 \u305f\u3060\u3057\u3001\u6e7f\u6c17\u306e\u591a\u304f\u306f\u6c17\u5019\u5909\u52d5\u3001\u51dd\u7e2e\u5f62\u5185\u5074\u7089\u306e\u4f4e\u6e1b\u3001\u7d76\u7e01\u6027\u80fd\u65ad\u71b1\u6027\u80fd\u3084\u53ef\u80fd\u6027\u304c\u77ed\u56de\u8def\u307e\u305f\u306f\u88c5\u7f6e\u3002 \u3053\u306e\u8a18\u4e8b\u306b\u306f\u4f55\u304c\u5fc5\u8981\u304b\u3092\u8003\u5bdf\u6b63\u4fb5\u5165\u4fdd\u8b77(IP)\u306e\u683c\u4ed8\u3051\u306e\u8a2d\u8a08\u3092\u652f\u63f4\u3059\u308b\u63aa\u7f6e\u304c\u52b9\u679c\u7684\u306b\u9632\u6b62\u51dd\u7e2e\u539f\u5b50\u7089\u3067\u306e\u55b6\u696d\u3001\u6e7f\u6c17\u306e\u591a\u3044\u3002 \u3092\u3054\u7d39\u4ecb\u3057\u307e\u56fd\u969b\u7684\u306b\u8a8d\u3081\u3089\u308c\u305f\u4fdd\u8b77\u57fa\u6e96\u306e\u5b9f\u8df5\u7684\u306a\u65b9\u6cd5\u3092\u30e6\u30fc\u30b6\u30fc\u3092\u9078\u629e\u3057\u3001\u7dad\u6301\u306b\u9069\u3057\u305f\u539f\u5b50\u7089\u306e\u88fd\u54c1\u306e\u6e7f\u3063\u305f\u74b0\u5883\u3067\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280552099611.png","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/17799280552099611.png","width":920,"height":498},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/how-can-reactors-avoid-condensation-in-humid-environments-through-protection-ratings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"How Can Reactors Avoid Condensation in Humid Environments Through Protection Ratings?"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS\u96fb\u6e90\u30c8\u30e9\u30f3\u30b9\u3001\u7089\u3067\u306f\u3001\u9ad8\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u6cb9\u5165\u5909\u5727\u5668-\u9577\u6c99(\u9577\u6c99\u7687\u51a0\u4eee\u65e5\u9152\u5e97)\u5eec\u5c71\u96fb\u5b50\u6280\u8853\u682a\u5f0f\u682a\u5f0f\u4f1a\u793e","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS\u96fb\u6e90\u30c8\u30e9\u30f3\u30b9\u3001\u7089\u3067\u306f\u3001\u9ad8\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u6cb9\u5165\u5909\u5727\u5668-\u9577\u6c99(\u9577\u6c99\u7687\u51a0\u4eee\u65e5\u9152\u5e97)\u5eec\u5c71\u96fb\u5b50\u6280\u8853\u682a\u5f0f\u682a\u5f0f\u4f1a\u793e","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/ja\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/posts\/1135","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/comments?post=1135"}],"version-history":[{"count":16,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/posts\/1135\/revisions"}],"predecessor-version":[{"id":7168,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/posts\/1135\/revisions\/7168"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/media\/3413"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/media?parent=1135"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/categories?post=1135"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/tags?post=1135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}