{"id":1305,"date":"2026-07-22T05:33:09","date_gmt":"2026-07-22T05:33:09","guid":{"rendered":"https:\/\/lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/"},"modified":"2026-10-29T06:55:41","modified_gmt":"2026-10-29T06:55:41","slug":"why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach","status":"publish","type":"post","link":"https:\/\/www.lstransformer.com\/ja\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/","title":{"rendered":"\u304c\u306a\u305c\u5fc5\u8981\u306a\u5730\u4e0a\u306e\u30c8\u30e9\u30f3\u30b9\u30b3\u30a2? \u306a\u305c\u306a\u3044\u3067\u306e\u4f7f\u7528\u304c\u304a\u52e7\u3081\u591a\u70b9\u63a5\u5730\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u8003\u3048\u3066\u3044\u307e\u3059\u304b\u3002"},"content":{"rendered":"<h1 style=\"text-align: left;\">\u304c\u306a\u305c\u5fc5\u8981\u306a\u5730\u4e0a\u306e\u30c8\u30e9\u30f3\u30b9\u30b3\u30a2? \u306a\u305c\u306a\u3044\u3067\u306e\u4f7f\u7528\u304c\u304a\u52e7\u3081\u591a\u70b9\u63a5\u5730\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u8003\u3048\u3066\u3044\u307e\u3059\u304b\u3002<b><\/b><\/h1>\n<p>\u306e\u82af\u3084\u91d1\u5c5e\u90e8\u54c1\u3092\u7570\u306a\u308b\u96fb\u4f4d\u306b\u3088\u308b\u4f4d\u7f6e\u306b\u3044\u3092\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3002 \u6642\u306e\u9593\u306b\u96fb\u4f4d\u5dee\u304c\u751f\u3058\u4e8c\u3064\u306e\u30dd\u30a4\u30f3\u30c8\u304c\u5341\u5206\u306b\u7d76\u7e01\u3057\u3001\u9593\u6b20\u706b\u82b1\u653e\u96fb\u304c\u767a\u751f\u3057\u307e\u3059\u3002 \u3053\u306e\u653e\u96fb\u306f\u65ad\u7d9a\u7684\u306f\u3001\u53ef\u80fd\u6027\u306e\u70b9\u304c\u7b49\u3057\u3044\u306f\u5404\u6392\u51fa\u5f8c\u306b\u8d77\u3053\u3057\u3001\u653e\u96fb\u306b\u5c45\u306a\u304f\u306a\u3063\u3066\u3057\u307e\u3063\u3066\u3044\u307e\u3059\u3002 \u4e00\u5ea6\u306e\u96fb\u4f4d\u5dee\u3092\u8a2d\u7acb\u3057\u518d\u767a\u8db3\u3001\u653e\u96fb\u304c\u767a\u751f\u3057\u307e\u3059\u3002 \u3053\u306e\u9593\u6b20\u7684\u653e\u51fa\u306e\u5206\u89e3\u306e\u30c8\u30e9\u30f3\u30b9\u6cb9\u7269\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u56fa\u4f53\u7d76\u7e01\u3001\u631f\u3093\u3060\u308a\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002 \u9632\u6b62\u7b49\u306e\u767a\u751f\u3001\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u91d1\u5c5e\u90e8\u54c1\u306a\u3069\u306e\u30af\u30e9\u30f3\u30d7\u5727\u5dfb\u677f\u306b\u63a5\u7d9a\u3055\u308c\u3066\u3044\u308b\u5fc5\u8981\u304c\u3042\u6cb9\u30bf\u30f3\u30af\u3001\u63a5\u308b\u3053\u3068\u3092\u4fdd\u8a3c\u3059\u308b\u305f\u3081\u306b\u306f\u540c\u96fb\u4f4d(\u30bc\u30ed\u306e\u53ef\u80fd\u6027). \u304c\u3042\u308b\u5834\u5408\u3092\u901a\u3058\u3066\u30b3\u30a2\u4ed8\u3051\u306e\u30b3\u30a2\u306f\u3001\u52b9\u679c\u7684\u306b\u540c\u3058\u3068\u3057\u3066\u306e\u53ef\u80fd\u6027\u3092\u30b3\u30a2\u306b\u3088\u308b\u5bb9\u91cf\u7d50\u5408\u3057\u3001\u5225\u306e\u7d20\u990a\u306f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u73fe\u5728\u306f\u3001\u5171\u901a\u306e\u63a5\u5730\u65b9\u6cd5\u3092\u3092\u4f38\u9285\u306e\u30b3\u30a2\u30b3\u30a2. \u306f\u7d76\u7e01\u30d5\u30a3\u30eb\u30e0\u306e\u30b3\u30a2\u30b3\u30a2\u306e\u4e2d\u6838\u3067\u304d\u308b\u63a5\u5730\u306e\u771f\u7a7a\u8a98\u5c0e.<\/p>\n<p>\u5834\u5408\u306e\u30b3\u30a2\u3092\u4e8c\u3064\u306e\u70b9\u3067\u540c\u7b49\u306e\u4f5c\u6210\u3092\u77ed\u56de\u8def\u306e\u4e21\u5074\u306b\u306f\u6838\u306b\u3088\u308a\u4e00\u5b9a\u984d\u306e\u73fe\u5728\u306e\u30d5\u30ed\u30fc\u3067\u3059\u3002 \u3053\u306e\u96fb\u6d41\u304c\u5730\u57df\u306e\u904e\u71b1\u304c\u5897\u52a0\u3057\u3001\u640d\u5931\u3044\u3066\u767a\u4f5c\u3092\u8d77\u3053\u3059\u5834\u5408\u304c\u3042\u308a\u3001\u63a5\u5730\u5e2f\u306b\u30d2\u30e5\u30fc\u30ba\u3001\u505c\u6b62\u306e\u53ef\u80fd\u6027\u3092\u8a8d\u3081\u306a\u3044\u3002<\/p>\n<p>\u305d\u306e\u305f\u3081\u3001\u30b3\u30a2\u5fc5\u305a\u63a5\u5730\u3057\u3066\u304a\u308a\u307e\u3059\u304c\u3001\u3053\u308c\u3092\u4f7f\u3063\u3066\u5358\u4e00\u63a5\u5730\u30dd\u30a4\u30f3\u30c8\u3002<\/p>\n<h2 style=\"font-weight: bold;\">\u9023\u7d61\u5148<\/h2>\n<p>\u5eec\u5c71,est\u3002 1975\u5e74\u306b\u306f\u4e2d\u56fd\u306e\u5c02\u9580\u8077\u306e\u5c02\u9580\u30e1\u30fc\u30ab\u30fc\u306e\u96fb\u529b\u5909\u5727\u5668\u53ca\u3073\u539f\u5b50\u7089\u306e\u305f\u3081\u306e50+\u308b\u3002 \u4e3b\u88fd\u54c1 <a href=\"https:\/\/www.lstransformer.com\/ja\/\">\u5358\u76f8\u30c8\u30e9\u30f3\u30b9\u3001\u4e09\u76f8\u7d76\u7e01\u5909\u5727\u5668\u3001\u96fb\u6c17\u30c8\u30e9\u30f3\u30b9\u3001\u7269\u6d41\u30c8\u30e9\u30f3\u30b9\u3001\u30b9\u30c6\u30c3\u30d7\u306e\u4e0b\u3001\u4fe1\u7528\u30ea\u30b9\u30af\u4ee5\u5916\u306e\u30ea\u30b9\u30af\u306b\u3064\u304d\u30c8\u30e9\u30f3\u30b9\u3001\u4f4e\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u9ad8\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u5236\u5fa1\u30c8\u30e9\u30f3\u30b9\u3001\u30c8\u30ed\u30a4\u30c0\u30eb\u30c8\u30e9\u30f3\u30b9\u3001R\u30b3\u30a2\u30c8\u30e9\u30f3\u30b9\u76f4\u6d41\u30a4\u30f3\u30c0\u30af\u30bf\u30fc\u3001AC\u7089\u3067\u306f\u3001\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u7089\u3001\u8ca0\u8377\u7089chokes\u3001\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u306e\u539f\u5b50\u7089\u306f\u3001\u4e2d\u9593\u4f53\u3001\u9ad8\u5468\u6ce2\u88fd\u54c1<\/a>.<\/p>\n<p>\u5f53\u793e\u306e\u96fb\u529b\u5909\u5727\u5668\u53ca\u3073\u539f\u5b50\u7089\u306b\u5e83\u304f\u4f7f\u7528\u3055\u308c\u306610\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3:\u9ad8\u901f\u9244\u9053\u3001\u5efa\u8a2d\u6a5f\u68b0\u3001\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3001\u30ed\u30dc\u30c3\u30c8\u3001\u533b\u7642\u6a5f\u5668\u3001\u70ad\u9271\u7206\u767a\u306e\u9632\u6b62\u3001\u52b1\u8d77\u30b7\u30b9\u30c6\u30e0\u3001\u771f\u7a7a\u713c\u7d50(\u7089)\u3001\u4e2d\u592e\u30a8\u30a2\u30b3\u30f3\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u77e5\u96fb\u6e90\u30c8\u30e9\u30f3\u30b9\u539f\u5b50\u7089: <a href=\"https:\/\/www.lstransformer.com\/ja\/\">www.lstransformer.com<\/a>.<\/p>\n<p>\u5e0c\u5f97\u306e\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30c8\u30e9\u30f3\u30b9\u3084\u539f\u5b50\u7089\u3001\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<br \/>\nWhatsApp\uff1a+86 13787095096<br \/>\n\u30e1\u30fc\u30eb:marketing@hnlsdz.com<\/p>","protected":false},"excerpt":{"rendered":"<p>Why is it necessary to ground the transformer core? And why is it not advisable to use a multi-point grounding approach? The core and its metal components generate different potentials due to their positions in the electric field. When the potential difference between two points reaches a level sufficient to break down the insulation between them, intermittent spark discharges occur. This discharge is intermittent, with the potential between the two points becoming equal after each discharge, causing the discharge to cease. Once a potential difference is reestablished, the discharge occurs again. This intermittent discharge can lead to the decomposition of transformer oil and potential damage to solid insulation, resulting in [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2827,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-1305","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Single-Point vs. Multi-Point Core Grounding<\/title>\n<meta name=\"description\" content=\"Compare single-point and multi-point transformer core grounding, including circulating-current risks and ground-fault monitoring. Check magnetic and mechanical requirements.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lstransformer.com\/ja\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Single-Point vs. Multi-Point Core Grounding\" \/>\n<meta property=\"og:description\" content=\"Compare single-point and multi-point transformer core grounding, including circulating-current risks and ground-fault monitoring. Check magnetic and mechanical requirements.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lstransformer.com\/ja\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/\" \/>\n<meta property=\"og:site_name\" content=\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T05:33:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-29T06:55:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742018639912329.png\" \/>\n\t<meta property=\"og:image:width\" content=\"370\" \/>\n\t<meta property=\"og:image:height\" content=\"276\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"369703005\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"369703005\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"3\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/\"},\"author\":{\"name\":\"369703005\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\"},\"headline\":\"Why is it necessary to ground the transformer core? And why is it not advisable to use a multi-point grounding approach?\",\"datePublished\":\"2026-07-22T05:33:09+00:00\",\"dateModified\":\"2026-10-29T06:55:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/\"},\"wordCount\":428,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1742018639912329.png\",\"articleSection\":[\"FAQ\"],\"inLanguage\":\"ja\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/\",\"name\":\"Single-Point vs. Multi-Point Core Grounding\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1742018639912329.png\",\"datePublished\":\"2026-07-22T05:33:09+00:00\",\"dateModified\":\"2026-10-29T06:55:41+00:00\",\"description\":\"Compare single-point and multi-point transformer core grounding, including circulating-current risks and ground-fault monitoring. Check magnetic and mechanical requirements.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1742018639912329.png\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/1742018639912329.png\",\"width\":370,\"height\":276},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.lstransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why is it necessary to ground the transformer core? And why is it not advisable to use a multi-point grounding approach?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lstransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#organization\",\"name\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.lstransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp\",\"width\":760,\"height\":202,\"caption\":\"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lstransformer.com\\\/#\\\/schema\\\/person\\\/674089c15f4857c19a997f886816d289\",\"name\":\"369703005\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g\",\"caption\":\"369703005\"},\"url\":\"https:\\\/\\\/www.lstransformer.com\\\/ja\\\/author\\\/369703005\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Single-Point vs. Multi-Point Core Grounding","description":"Compare single-point and multi-point transformer core grounding, including circulating-current risks and ground-fault monitoring. Check magnetic and mechanical requirements.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lstransformer.com\/ja\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/","og_locale":"ja_JP","og_type":"article","og_title":"Single-Point vs. Multi-Point Core Grounding","og_description":"Compare single-point and multi-point transformer core grounding, including circulating-current risks and ground-fault monitoring. Check magnetic and mechanical requirements.","og_url":"https:\/\/www.lstransformer.com\/ja\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/","og_site_name":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD","article_published_time":"2026-07-22T05:33:09+00:00","article_modified_time":"2026-10-29T06:55:41+00:00","og_image":[{"width":370,"height":276,"url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742018639912329.png","type":"image\/png"}],"author":"369703005","twitter_card":"summary_large_image","twitter_misc":{"\u57f7\u7b46\u8005":"369703005","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"3\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/#article","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/"},"author":{"name":"369703005","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289"},"headline":"Why is it necessary to ground the transformer core? And why is it not advisable to use a multi-point grounding approach?","datePublished":"2026-07-22T05:33:09+00:00","dateModified":"2026-10-29T06:55:41+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/"},"wordCount":428,"publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"image":{"@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742018639912329.png","articleSection":["FAQ"],"inLanguage":"ja"},{"@type":"WebPage","@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/","url":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/","name":"Single-Point vs. Multi-Point Core Grounding","isPartOf":{"@id":"https:\/\/www.lstransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/#primaryimage"},"image":{"@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742018639912329.png","datePublished":"2026-07-22T05:33:09+00:00","dateModified":"2026-10-29T06:55:41+00:00","description":"Compare single-point and multi-point transformer core grounding, including circulating-current risks and ground-fault monitoring. Check magnetic and mechanical requirements.","breadcrumb":{"@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/#primaryimage","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742018639912329.png","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/07\/1742018639912329.png","width":370,"height":276},{"@type":"BreadcrumbList","@id":"https:\/\/www.lstransformer.com\/why-is-it-necessary-to-ground-the-transformer-core-and-why-is-it-not-advisable-to-use-a-multi-point-grounding-approach\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.lstransformer.com\/"},{"@type":"ListItem","position":2,"name":"Why is it necessary to ground the transformer core? And why is it not advisable to use a multi-point grounding approach?"}]},{"@type":"WebSite","@id":"https:\/\/www.lstransformer.com\/#website","url":"https:\/\/www.lstransformer.com\/","name":"LS\u96fb\u6e90\u30c8\u30e9\u30f3\u30b9\u3001\u7089\u3067\u306f\u3001\u9ad8\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u6cb9\u5165\u5909\u5727\u5668-\u9577\u6c99(\u9577\u6c99\u7687\u51a0\u4eee\u65e5\u9152\u5e97)\u5eec\u5c71\u96fb\u5b50\u6280\u8853\u682a\u5f0f\u682a\u5f0f\u4f1a\u793e","description":"","publisher":{"@id":"https:\/\/www.lstransformer.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lstransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/www.lstransformer.com\/#organization","name":"LS\u96fb\u6e90\u30c8\u30e9\u30f3\u30b9\u3001\u7089\u3067\u306f\u3001\u9ad8\u96fb\u5727\u30c8\u30e9\u30f3\u30b9\u3001\u6cb9\u5165\u5909\u5727\u5668-\u9577\u6c99(\u9577\u6c99\u7687\u51a0\u4eee\u65e5\u9152\u5e97)\u5eec\u5c71\u96fb\u5b50\u6280\u8853\u682a\u5f0f\u682a\u5f0f\u4f1a\u793e","url":"https:\/\/www.lstransformer.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","contentUrl":"https:\/\/www.lstransformer.com\/wp-content\/uploads\/2026\/06\/cropped-7e09bd7bad9c830e0d75b8487b0d77c3-1.webp","width":760,"height":202,"caption":"LS power transformer, Line reactor, High-voltage transformer, Oil-immersed transformer-CHANGSHA LUSHAN ELECTRONIC TECHNOLOGY CO.,LTD"},"image":{"@id":"https:\/\/www.lstransformer.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lstransformer.com\/#\/schema\/person\/674089c15f4857c19a997f886816d289","name":"369703005","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/dcaa0e47cd7b6c99ffdd80f5772032ed2d2591b5b8e7b905e5fd87a850954248?s=96&d=mm&r=g","caption":"369703005"},"url":"https:\/\/www.lstransformer.com\/ja\/author\/369703005\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/posts\/1305","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/comments?post=1305"}],"version-history":[{"count":4,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/posts\/1305\/revisions"}],"predecessor-version":[{"id":6717,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/posts\/1305\/revisions\/6717"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/media\/2827"}],"wp:attachment":[{"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/media?parent=1305"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/categories?post=1305"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lstransformer.com\/ja\/wp-json\/wp\/v2\/tags?post=1305"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}