When is it not allowed to adjust the on-load tap changer of a transformer?

Home > FAQ > When is it not allowed to adjust the on-load tap changer of a transformer?

When is it not allowed to adjust the on-load tap changer of a transformer?

微信分享

请复制下面链接,在微信内打开分享
https://www.lstransformer.com/when-is-it-not-allowed-to-adjust-the-on-load-tap-changer-of-a-transformer/

When is it not allowed to adjust the on-load tap changer of a transformer?

During the operation and maintenance of a transformer, the adjustment of the on-load tap changer (OLTC) needs to strictly adhere to regulations to ensure the safe and stable operation of the transformer. Here are several situations in which adjusting the OLTC is not permitted:

During transformer overload operation: Overloading can cause an increase in internal temperatures, and adjusting the tap changer at this time may lead to insulation aging of the transformer windings or even trigger a failure. However, in special circumstances, such as the need to temporarily adjust the tap changer to ensure grid stability, it should be done strictly according to regulations, and normal load should be restored promptly after adjustment.

When signals of frequent gas protection alarms from the OLTC are detected: Frequent gas protection signals indicate a possible internal fault in the transformer, and adjusting the tap changer is not allowed at this time.

When the transformer’s OLTC oil gauge shows no oil or an excessively low oil level: Transformer oil is crucial for proper cooling and insulation, and a low oil level can lead to overheating and insulation problems. The oil level issue should be addressed before making any adjustments.

When the number of tap changes exceeds the specified limit: Excessive tap changes may indicate wear or overheating issues in the transformer windings or OLTC and require the transformer to be shut down for inspection and maintenance.

When the OLTC malfunctions: Malfunctions in the OLTC can lead to unstable output voltage from the transformer, affecting grid operation. Adjustments should only be made after troubleshooting and rectifying the OLTC malfunction.

Contact

LuShan, est. 1975, is a Chinese professional manufacturer specializing in power transformers and reactors for 50+ years. Leading products are single-phase transformer, three-phase isolation transformers, electrical transformer, distribution transformer, step down and step up transformer, low voltage transformer, high voltage transformer, control transformer, toroidal transformer, R-core transformer; DC inductors, AC reactors, filtering reactor, line and load reactor, chokes, filtering reactor, and intermediate, high-frequency products.

Our power transformers and reactors are widely used in 10 application areas: rapid transit, construction machinery, renewable energy, intelligent manufacturing, medical equipment, coal mine explosion prevention, excitation system, vacuum sintering(furnace), central air conditioning.

Know more about power transformer and reactor: www.lstransformer.com.

If you would like to obtain customized solutions for transformers or reactors, please contact us.
WhatsApp:+86 13787095096
Email: marketing@hnlsdz.com

WhatsApp QR WeChat QR sales@hnlsdz.com
Scroll to Top