What are the routine electrical tests for transformers? (Part 1)

ホーム > FAQ > What are the routine electrical tests for transformers? (Part 1)

What are the routine electrical tests for transformers? (Part 1)

微信分享

请复制下面链接,在微信内打开分享
https://www.lstransformer.com/ja/what-are-the-routine-electrical-tests-for-transformers-part-1/

What are the routine electrical tests for transformers? (Part 1)

Transformers play a central role in power transmission and distribution, and their stable operation is related to the safety of the entire power system. Routine electrical tests are important means to detect the performance of transformers and discover potential faults.

コンテンツ

1. Voltage ratio test

The voltage ratio test is mainly used to verify whether the voltage ratio of the transformer meets the design requirements. Through this test, it can be detected whether there are short circuits between turns or layers of the winding and whether the switch leads are wrongly connected. In actual operation, accurately measuring the voltage ratio between different windings can timely discover potential electrical connection problems and ensure the normal voltage transformation function of the transformer.

2. Winding resistance measurement

The winding resistance measurement can judge the welding quality of the wire and detect whether there are faults such as short circuits in the winding, poor switch contact or wrongly connected leads. Accurately measuring the winding resistance can reflect the conductive performance of the winding, which is of great significance for discovering potential short circuit or poor contact problems. By measuring and comparing the winding resistance at different positions, the fault location can be quickly located and the fault removal efficiency can be improved.

3. Insulation resistance and absorption ratio or polarization index measurement

Use a 2500V megger to measure the insulation resistance R at 60 seconds and compare it with the insulation resistance Rs at 15 seconds to obtain the insulation resistance and absorption ratio Ro/R₁s or polarization index. This is a sensitive indicator for judging the insulation deterioration and moisture absorption degree of the transformer. This test can detect the performance of the insulation material of the transformer. By comparing the insulation resistance values at different time points, it can be judged whether the insulation material is aged or moistened. At the same time, the local defects or moisture absorption of insulation cardboard, bushings and windings can also be represented by the ratio.

未定義

概要

In conclusion, the routine electrical tests of transformers cover multiple aspects, including voltage ratio test, winding resistance measurement, insulation resistance and absorption ratio or polarization index measurement, tanδ measurement, oil test, withstand voltage test, no-load and load tests, etc. These tests cooperate with each other to comprehensively detect the performance and reliability of the transformer, timely discover potential faults and defects, and provide strong guarantee for the safe operation of the transformer.

連絡先

廬山,est。 1975年には中国の専門職の専門メーカーの電力変圧器及び原子炉のための50+る。 主製品 単相トランス、三相絶縁変圧器、電気トランス、物流トランス、ステップの下、信用リスク以外のリスクにつきトランス、低電圧トランス、高電圧トランス、制御トランス、トロイダルトランス、Rコアトランス直流インダクター、AC炉では、フィルタリング炉、負荷炉chokes、フィルタリングの原子炉は、中間体、高周波製品.

当社の電力変圧器及び原子炉に広く使用されて10アプリケーション:高速鉄道、建設機械、再生可能エネルギー、ロボット、医療機器、炭鉱爆発の防止、励起システム、真空焼結(炉)、中央エアコンがあります。

知電源トランス原子炉: www.lstransformer.com.

希得のカスタマイズソリューションのためのトランスや原子炉、お問い合わせください。
WhatsApp:+86 13787095096
メール:marketing@hnlsdz.com

WhatsAppにQR WeChat QR sales@hnlsdz.com
スクロールトップ