Какие меры принимаются для предотвращения старения изоляции трансформаторов?

Вопросы и ответы

Какие меры принимаются для предотвращения старения изоляции трансформаторов?

What are the measures to avoid insulation aging of transformers? Transformers play a key role in the power system, and insulation aging can seriously affect their performance and lifespan. To ensure the safe and stable operation of transformers, it is crucial to take effective measures to avoid insulation aging. Content 1.  Optimize the operating environment

Вопросы и ответы

What is on-load voltage regulation of transformers? (Part 2)

What is on-load voltage regulation of transformers? (Part 2) The principle of on-load voltage regulation is to set multiple taps on the high-voltage winding or low-voltage winding of the transformer. By switching the tap changer, different taps are connected to the circuit to change the number of turns of the winding and then adjust the output

Вопросы и ответы

What is the function of a reactor?

What is the function of a reactor? Reactor commonly used in power systems include series reactors and shunt reactors. Series reactors are primarily used to limit short-circuit currents, and they can also be connected in series or parallel with capacitors in filters to limit high-order harmonics in the grid. Reactors in 220kV, 110kV, 35kV, and

Вопросы и ответы

How to Suppress Reactor Resonance Overvoltage? – Collaborative Design of Damping Resistors and Filters

How to Suppress Reactor Resonance Overvoltage?  – Collaborative Design of Damping Resistors and Filters In power system operation, the LC resonance circuit formed by reactors and distributed capacitance can generate dangerous overvoltage phenomena. According to measured data from IEEE Std. C57.21-2021, the peak resonance overvoltage can reach 2-3 times the rated voltage, posing a serious

Вопросы и ответы

Как осуществляется молниеотводная защита трансформатора?

How is the lightning arrester protection of the transformer carried out? The lightning arrester is the most crucial basic component for protecting power generation equipment and transmission and transformation equipment. It also forms the foundation for determining the insulation level of high-voltage electrical equipment. Installed in front of the transformer, the arrester mainly consists of

Вопросы и ответы

Как задаются значения отклонения параметров трансформатора и параметров, использующих пиковые значения?

How are the deviation values of transformer parameters and the parameters using peak values specified? The specifications for evaluating the performance parameters of transformers are determined by technical conditions, and each standard value has corresponding deviation values, which can be categorized into several types: (1) Parameters with only a lower limit specified, without an upper

Вопросы и ответы

Как проводится измерение сопротивления изоляции и коэффициента поглощения?

How is the measurement of insulation resistance and absorption ratio conducted? Insulation resistance, denoted as R, is typically determined by applying a voltage of 2500V for 60 seconds and measuring the resulting value using a megohmmeter with a maximum range of 10000 MQ. Due to variations in the stability of insulation resistance arising from differences